Medikal implantlarda kullanılan biyomalzemelerin manyetik rezonans cihazı uyumluluğu ve güvenilirliğinin analizi

Magnetic resonance device compatibility and safety analysis of biomaterials used in medical implants

  1. Tez No: 432330
  2. Yazar: ÖMER BURAK İSTANBULLU
  3. Danışmanlar: YRD. DOÇ. GÜLŞEN AKDOĞAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Mühendislik Bilimleri, Engineering Sciences
  6. Anahtar Kelimeler: Biyomalzemeler, Manyetik rezonans görüntüleme, Biomaterials, Magnetic resonance imaging
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: Erciyes Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Biyomedikal Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Manyetik Rezonans Görüntüleme (MRG) cihazı; insan sağlığına zararsız olması ve yüksek çözünürlükteki görüntü kalitesi nedeniyle diğer teşhis cihazlarına göre tercih edilebilir. Ancak, vücutta bulundurulan herhangi bir implantın MRG ile uyumsuz olabileceği endişesi ile kullanımından kaçınılmaktadır. MRG ortamında, elektriksel iletkenliğe sahip ve ferromanyetik özellikteki tıbbi amaçlı biyomalzemeler; yüksek güçteki statik manyetik alan, manyetik radyo frekans dalgaları ve gradient manyetik alan ile elektromanyetik etkileşime girme potansiyeline sahiptir. Bu etkileşimin MRG uyumlu olmayan malzemelerde; sıcaklık artışı, manyetik kuvvet ve tork oluşumu gibi fiziksel etkileri meydana gelmesiyle biyomalzemeyi çevreleyen sağlıklı dokular zarara uğramaktadır. İmplantların MRG uyumlu olanlarının ayırt edilmesi amacıyla üretim aşamasında iken MRG uyumluluk/güvenilirlik testlerinin yapılmış olması problemi giderecektir. Bu çalışmada ise öncelikle vücuttaki farklı organların elektriksel iletkenlik seviyeleri tespit edilmiş, ardından Sim4Life paket programı aracılığı ile insan vücut şartlarına yakın koşullar bilgisayar ortamında simule edilmiştir. Simulasyon ortamında fantom ve malzemeler türetilerek, MRG sırasındaki elektromanyetik enerji dağılımı ve malzemenin ısınma etkisi incelenmiştir. Gerçek MRG ortamındaki malzemelerin davranışlarının analizi için ise 3 farklı tasarımda, 7 farklı malzeme içeriğine sahip, 21 ayrı deney numunesi kullanılmıştır. Numunelerin RF etkili ısınma ve MR görüntülerinde oluşan bozulma miktarları 4 ayrı MRG koşulu olan;“Aksiyal ve Sagital T1 Gradient Eko”ve“Aksiyal ve Sagital T2 Turbo Spin Eko”görüntüleme sekanslarında incelenmiştir. Test edilen numunelerin MR uyumluluk seviyelerini belirlemede ASTM standartları referans alınmıştır.

Özet (Çeviri)

Magnetic Resonance Imaging (MRI) device is preferred in comparison with the other diagnostic devices due to being harmless to human health and high resolution image quality. However, usage is avoided owing to the apprehension of whatsoever implant inside the body might be MRI incompatible. Electrically conductive and ferromagnetic featured medical aimed biomaterials have electromagnetic interaction potential with quite strong static magnetic field, magnetic radio frequency pulses and gradient magnetic fields inside the MRI environment. Healthy tissues surrounding biomaterials suffer damage due to the fact that physical effects of mentioned interaction such as temperature increase, magnetic force and torque formation on the MRI incompatible material. In an attempt to distinguish implants which are MRI compatible, doing compatibility/safety tests at the production phase will overcome the problem. In this study, firstly electrical conductivity level of different organs in the body is determined then conditions close to body circumstances are simulated by Sim4Life packaged software in computer environment. Electromagnetic energy distribution and heating effect of material is examined by creating phantom and materials in simulation environment. 21 individual test samples which are 3 different designed and have 7 different material content are used to analyse behavior of material inside real MRI environment. RF induced heating and deformation level of MR images of samples are examined in 4 different MRI conditions which are“Axial and Sagittal T1 Gradient Echo”and“Axial and Sagittal T2 Turbo Spin Echo”imaging sequences. ASTM standards are used as reference for determining MRI compatibility level of test samples.

Benzer Tezler

  1. Manyetik rezonans görüntülerinde tümör bölgelerinin otomatik tespiti

    Automatic detection of tumor zones in magmetic resonance images

    HÜSAMETTİN MERT TEZCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Elektrik ve Elektronik Mühendisliğiİstanbul Arel Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ GÖKALP TULUM

  2. Çinko stearat katkılı fonksiyonel derecelendirilmiş toz metal 316L paslanmaz çeliğin üretimi ve karakterizasyonu

    Production and characterization of zinc stearate added functional graded powder metal 316L stainless steel

    MAHMUD ESAD TEKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    BiyomühendislikKarabük Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    PROF. DR. MEHMET AKİF ERDEN

  3. Mammografi ve ultrasonografinin meme kanseri tanısında yeri

    Başlık çevirisi yok

    CEBBAR ÇALIŞKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Genel CerrahiGata

    Genel Cerrahi Ana Bilim Dalı

  4. İdrar kültürlerinden izole edilen coag (-) staphylococcus (s. epidrmidis ve s. saprophyticus)'ların idrar yolu enfeksiyonlarındaki yeri

    The Place of coag (-) staphylococcus to the urinary tract infectron which are isolated from the urine cultures

    SUMRU ÇITAK(KORMAN)

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    ÜrolojiGazi Üniversitesi

    YRD. DOÇ. DR. URAZ GÜVEN

  5. Ferrokrom fabrikasında çalışan işçilerde stogenetik çalışmalar

    Başlık çevirisi yok

    AYNUR ACAR

    Doktora

    Türkçe

    Türkçe

    1985

    Tıbbi BiyolojiAkdeniz Üniversitesi

    Tıbbi Biyoloji ve Genetik Ana Bilim Dalı

    DOÇ. DR. GÜVEN LÜLECİ