Dar çaplı implantlarda açılı ve düz titanyum abutment vidalarının farklı dinamik yüklemeler sonucu oluşan tork kaybı ve vida gevşemesinin in-vitro incelenmesi
Torque decrement and screw loosening values resulting under different dynamic loadings on angled and straight titanium abutment with narrow diameter implants: An in-vitro investigation
- Tez No: 460379
- Danışmanlar: PROF. DR. ASLIHAN ÜŞÜMEZ
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2016
- Dil: Türkçe
- Üniversite: Bezm-i Alem Vakıf Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 88
Özet
Bu tez çalışmasında amacımız; dar çaplı implantlar üzerinde, açılı ve düz abutmentların farklı dinamik yükleme siklusları sonrası oluşan tork kaybı ve vida gevşeme değerlerini in-vitro olarak incelemek ve dinamik yükleme öncesi değerler ile karşılaştırmaktır. Yöntem ve Gereç: Çalışmamızda, 40 adet 3,5 mm çaplı 10 mm boyunda implantlar ve üst yapı olarak 20 adet düz, 20 adet 15° açılı titanyum abutmentlar kullanılmıştır. Örnekler, 4 alt gruba ayrılmıştır: 1.grup: Düz abutmentların 3x105 kez dinamik yüklenmesi (Grup: D3), 2.grup: Düz abutmentların 6x105 kez dinamik yüklenmesi (Grup: D6), 3.grup: 15° açılı abutmentların 3x105 kez dinamik yüklemesi (Grup: A3), ve 4.grup: 15° açılı abutmentların 6x105 kez dinamik yüklenmesidir (Grup: A6). Dinamik yükleme siklusu öncesi her abutment vidası 3 kez 30 N.cm tork ile sıkılıp ardından gevşetme işlemine tabi tutulmuştur. Oluşan gevşeme tork değerleri (1. 2. ve 3. GTD) not edilmiştir. Daha sonra örnekler yeni vida ile 30 Ncm tork ile sıkılıp dinamik yükleme işlemlerine tabi tutulmuştur. Dinamik yükleme sikluslarından sonra GTD'ler 4.GTD olarak not edilmiştir. Ayrıca yorulmuş vida son kez sıkma-gevşetme siklusuna tabi tutulmuş ve 5. GTD elde edilmiştir. Sonuç olarak her örnek için toplam 5 adet GTD elde edilmiştir. Bu değerler, gruplar içinde ve gruplar arasında tekrarlayan ölçümlerde ANOVA, iki yönlü ANOVA ve Tukey HSD testleri ile karşılaştırılmıştır. Bulgular: Dinamik yükleme sikluslarından sonra gruplar arasında anlamlı bir fark gözlenmemiştir (p>0.05) (D3: 26,43±0,72, D6: 26,05±0,75, A3:26,40±0,73, A6:26,27±0,80). Tüm gruplarda; 4. GTD; 1. 2. ve 3. GTD'lerden anlamlı olarak düşüktür (p 0,05). A3 grubunda 5. GTD ile 2. GTD arasında istatistiksel olarak anlamlı fark vardır. Sonuç: Dinamik yükleme GTDyi anlamlı ölçüde azaltmaktadır. Dinamik yükleme öncesi açılı abutmentlar, düz abutmentlara göre daha yüksek başlangıç GTD göstermişlerdir. 5.GTD sonuçlarına göre; D3 ve D6 gruplarında 5.GTD ile 1. 2. ve 3. GTD arasında anlamlı fark yok iken, A6 grubunda 5.GTD ile 1. 2. ve 3. GTD arasında, A3 grubunda 5.GTD ile 2. GTD arasında anlamlı fark vardır. Özellikle açılı abutment kullanımında yorulmuş vidanın yeni vida ile değiştirilmesi daha faydalı olabilir.
Özet (Çeviri)
The aim of this in-vitro study is to investigate straight and angled titanium abutments' torque relaxation and screw loosening values under different dynamic loading cycles for narrow diameter implants and to compare values after dynamic loadings and previous values. Material and methods: 40 samples of 3,5 mm diameter 10 mm length implants and as superstructure 20 samples of straight and 15° angled titanium abutment were used. Samples divided in to 4 groups: 1. Group: 3x105 dynamic load cycles on straight abutment (Group D3), 2. Group: 6x105 dynamic load cycles on straight abutment (Group D6), 3. Group: 3x105 dynamic load cycles on angled abutment (Group A3) and 4. Group: 6x105 dynamic load cycles on angled abutment (Group A6). Before dynamic load cycles, every abutment screws were fastened and loosed 3 times with 30 N.cm torque. The loosening torque values (GTD's) were measured and registered as 1. 2. and 3. GTD's. Then, samples were fastened again with new screws with 30 N.cm torque value and subjected to different dynamic load procedure. After dynamic cycles, GTD's remeasured as 4.GTD's. Finally, aged screw were subjected to one more time fastened-loosening cycles and obtained 5.GTD values. As a result, five GTD's were measured for every sample. These values were compared with repeated ANOVA, two-way ANOVA and Tukey HSD tests in groups and among the groups. Results: After dynamic load cycles, there were no significantly differences among the groups (p>0,05) (D3: 26,43±0,72, D6: 26,05±0,75, A3:26,40±0,73, A6:26,27±0,80). In all groups 4. GTS was significantly lower than 1. 2. and 3. GTD (p 0,05). In A3 group, there were statistically significantly differences between 5.GTD and 2. GTD. Conclusion: GTD values were significantly decreased by dynamic loading procedures. Before dynamic loads, initial GTD values were measured and found that angled abutments have higher initial GTD values than straight abutments. According to 5.GTD results; while there were no significantly difference between 5.GTD's with 1. 2. and 3. GTD's on D3 and D6 groups, there were significantly difference between 5.GTD with 1. 2. and 3 GTD's on A6 group and between 5.GTD with 2.GTD on A3 group. Particularly, changing of aged screw to new screw could be more advantageous in angled abutment usage
Benzer Tezler
- Maksilla anterior bölge tek diş eksikliğinde dar çaplı implant ile rehabilite edilen vakalarda implant geometrisi ve yüzey tasarımının stres dağılımına etkisinin sonlu elemanlar analizi ile incelenmesi
Investigation of the effect of implant geometry and surface design on stress distribution with finite element analysis in cases rehabilitated with narrow-diameter implants a single missing tooth in the maxillary anterior region
AYŞEGÜL TEKELİ YAVUZ
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiSelçuk ÜniversitesiAğız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
PROF. DR. ERCAN DURMUŞ
- Farklı materyallerden imal edilerek üst yapısı tamamlanan dar çaplı dental implantların kırılma dayanımlarının karşılaştırılmalı olarak incelenmesi
Comparative investigation of fracture resistance of narrow diameter dental implants fabricated from different materials with single crown restoration
YAĞMUR KAHRAMAN BANAZLI
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiSivas Cumhuriyet ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. OĞUZHAN GÖRLER
- Farklı cerrahi tekniklerle yerleştirilen implantların primer stabilitelerinin karşılaştırılması
Comparison of primary stabilities of implants placed by different surgical techniques
BATUR ORAK
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiFırat ÜniversitesiAğız Diş ve Çene Cerrahisi Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ONUR EVREN KAHRAMAN
- Dar çaplı implantlarda farklı abutment kullanımının vida gevşemesi üzerine etkisi
The effect of different abutments on screw loosening in narrow diameter implants
BÜŞRA ALTUNTOP
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiOndokuz Mayıs ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. TOLGA KÜLÜNK
- Tam dişsiz mandibulanın eğimli implantlarla rehabilitasyonunda farklı tip ve çaplardaki implantların ve farklı protetik alt yapı materyallerinin stres dağılımına etkisinin sonlu elemanlar analizi ile incelenmesi
Observation of the effect of different material and diameters of implants anddifferent framework materials on stress distribution i̇n rehabilitation of fulledentulous mandible with tilted implants by finite element analysis
AYŞE UYSAL
Diş Hekimliği Uzmanlık
Türkçe
2019
Diş HekimliğiTokat Gaziosmanpaşa ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DR. ÖĞR. ÜYESİ YELİZ HAYRAN