Maksilla anterior bölge tek diş eksikliğinde dar çaplı implant ile rehabilite edilen vakalarda implant geometrisi ve yüzey tasarımının stres dağılımına etkisinin sonlu elemanlar analizi ile incelenmesi

Investigation of the effect of implant geometry and surface design on stress distribution with finite element analysis in cases rehabilitated with narrow-diameter implants a single missing tooth in the maxillary anterior region

  1. Tez No: 743648
  2. Yazar: AYŞEGÜL TEKELİ YAVUZ
  3. Danışmanlar: PROF. DR. ERCAN DURMUŞ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: İmplant dizaynı, Konik implant, Silindirik implant, Sonlu elemanlar analizi, Conical implant, Cylindrical implant, Finite element analysis, Implant design
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 143

Özet

Amaç Bu çalışmada, maksilla anterior bölge tek diş eksikliğinde dar çaplı implant ile rehabilite edilen vakalarda, implant üzerinde oluşan stresler ile implant tasarımı arasındaki ilişkinin deneysel olarak araştırılması amaçlanmıştır. Çalışmamızda farklı dizaynlara sahip dar çaplı implantların dikey ve açılı kuvvetlere maruz bırakılması sonucunda meydana gelen stres dağılımının sonlu elemanlar analizi ile incelenmesi amaçlanmıştır. Gereç ve Yöntemler Çalışmamızda bilgisayar ortamında maksilla anterior bölgedeki kemik yoğunluğunu taklit eden modellemeler yapıldı. Hazırlanan modellere silindirik ve konik şekilli olmak üzere ve farklı yiv tasarımına (kare, payanda, ters payanda, v şekilli yiv) ait dar çaplı implantlar yerleştirildi. İmplantların çapı standart 3,3 mm olarak, uzunlukları ise 12 mm olarak belirlendi. Toplam 8 grup olarak tasarlandı. Bu implantlara dikey yönde ve 30 derece açılı oblik 100 N'luk kuvvet uygulandı. İmplantlarda oluşan von-mises stres değerleri ve asal stresler ile kemik-implant arayüzündeki stres değerleri sonlu eleman analiz tekniği ile incelenmiştir. Bulgular Tüm modellerde implantın boyun bölgesini çevreleyen kortikal kemikte meydana gelen stresler, trabeküler kemikte meydana gelen streslerden daha yüksek bulunmuştur. Tüm modellerimizde en yüksek stres değerleri, yükleme alanına daha yakın implantların çevresinde görülmüştür. Oblik kuvvetler dikey kuvvetlerden hem implant hem çevre kemik dokuda daha fazla stres meydana getirmektedir. Dört farklı yiv tipi karşılaştırıldığında kare yiv formunda Von Mises stres değeri daha düşük bulunmuştur. Payanda yiv şekilli implantta belirgin şekilde tüm gruplara göre daha fazla stres oluşmuştur. Sonuç Ön bölgelerde konik ve silindirik implant tüm yiv şekillerinde implant tasarımları tercih edilebilir. Ancak silindirik implatın en çok stresin oluştuğu bölge olan boyun kırıklarına sebep olabileceği, konik implantların ise kemikte meydana getirdiği streslerin daha fazla olacağı bilinmelidir. Dört farklı yiv tipi karşılaştırıldığında kare yiv formunda Von Mises stres değeri daha düşük bulunmuştur. Yapılan çalışmada 21 nolu diş bölgesine 100 N'lik kuvvet vertikal ve 30° açılı uygulanmış ve kemikte rezorpsiyon meydana getirecek kadar stresin oluşmadığı gözlenmiştir. Ancak payanda yiv şekilli implantta belirgin tüm gruplara göre daha fazla stres oluşmuştur. Buna göre kare, V şekilli ve ters payanda yiv şekilli implantların öncelikli olarak tercih edilmesi sonucuna varılabilir.

Özet (Çeviri)

Aim This study, it was aimed to experimentally investigate the relationship between the stresses on the implant and the implant design in cases rehabilitated with a narrow-diameter implant in a single missing tooth in the maxillary anterior region. Our study, it is aimed to examine the stress distribution that occurs as a result of exposure of narrow diameter implants with different designs to vertical and angular forces by finite element analysis. Materials and Methods Our study, models imitating bone density in the maxilla anterior region were made in the computer environment. Cylindrical and conical shaped and narrow diameter implants of different thread designs (square, buttress, reverse buttress, v-shaped thread) were placed in the prepared models. The diameter of the implants was determined as a standard 3.3 mm, and their length was determined as 12 mm. It was designed as 8 groups in total. An oblique force of 100 N was applied to these implants in the vertical direction and at an angle of 30 degrees. The von-mises stress values ​​and principal stresses in the implants and the stress values ​​at the bone-implant interface were investigated by finite element analysis technique. Results In all models, the stresses on the cortical bone surrounding the neck of the implant were higher than the stresses on the trabecular bone. The highest stress values ​​were observed around the implants closer to the loading area in all our models. Oblique forces create more stress on both the implant and the surrounding bone tissue than vertical forces. When four different thread types were compared, Von Mises stress value was found to be lower in square thread form. Significantly more stress occurred in the buttress-shaped implant than in all groups. Conclusion Implant designs can be preferred in all thread shapes of conical and cylindrical implants in the anterior regions. However, it should be known that cylindrical implants may cause neck fractures, which is the region where the most stress occurs, while conical implants will cause more stress on the bone. When four different thread types were compared, Von Mises stress value was found to be lower in square thread form. A force of 100 N was applied vertically and at an angle of 30° and it was observed that the stress did not occur enough to cause resorption in the bone. However, significantly more stress occurred in the buttress-shaped implant than in all groups. Accordingly, it can be concluded that square, V-shaped and reverse buttress-shaped implants are primarily preferred.

Benzer Tezler

  1. Tek diş implantların klinik, radyografik, estetik ve hasta memnuniyeti açısından kontralateral dişler ile karşılaştırılması

    Comparison of single-tooth dental implants with contralateral teeth i̇n terms of clinical, radiographic, aesthetic and patient satisfaction

    MERVE KÜÇÜKOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiZonguldak Bülent Ecevit Üniversitesi

    Periodontoloji Ana Bilim Dalı

    PROF. DR. MURAT İNANÇ CENGİZ

  2. Assessment of hard tıssue densıty around dental ımplants usıng conventıonal radıographs

    Dental implantlar çevresindeki sert doku densitesinin konvensiyonel radyograflar ile incelenmesi

    WAEL ALSHAIBANI

    Doktora

    İngilizce

    İngilizce

    2010

    Diş HekimliğiGazi Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. DR. NUR MOLLAOĞLU

  3. Estetik bölge tek diş eksikliklerinde hemen yüklenen 'platform SWITCH' implantların değerlendirilmesi

    Evaluation of immediate loaded platform SWİTCH implants in the single tooth missing of esthetic zone

    PINAR YILDIZ

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiErciyes Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. MUSTAFA ZORTUK

  4. Canalis sinuosus morfolojisinin konik ışınlı bilgisayarlı tomografi ile retrospektif olarak incelenmesi

    Retrospective evaluation of canalis sinuosus morphology by cone BEAM computed tomography

    İRFAN ÇELİK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş Hekimliğiİstanbul Üniversitesi

    Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı

    PROF. DR. İLKNUR ÖZCAN

  5. Dudak damak yarıklı bireylerde maksiller distraksiyon osteogenezisinin sonlu elemanlar yöntemi ile değerlendirilmesi

    Evaluation of maxillary distraction osteogenesis in patients with cleft lip and palate using finite element method

    SULTAN ÖLMEZ

    Doktora

    Türkçe

    Türkçe

    2012

    Diş HekimliğiEge Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. SERVET DOĞAN