Geri Dön

Farklı ışık kaynakları ile farklı sürelerde polimerize edilen bulk fill kompozitlerin alt-üst yüzey sertlik değerlerinin karşılaştırmalı olarak incelenmesi

Influence of bulk thickness, curing time and curing unit on the microhardness of different viscosity bulk fill composites

  1. Tez No: 466750
  2. Yazar: MIIIDDIN SAIPULLAEV
  3. Danışmanlar: DOÇ. DR. UĞUR ERDEMİR
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental materyaller, Dental restorasyon, Kompozit malzemeler, Kompozit reçineler, Mikrosertlik, Polimerleşme, Yüzey sertliği, Dental materials, Dental restoration, Composite materials, Composite resins, Microhardness, Polymerization, Surface hardness
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, farklı tipteki Bulk fill kompozit reçinelerin, farklı tip ışık cihazları ile farklı ışık uygulama sürelerinde ve farklı yüksekliklerde polimerize edilmesinin, alt/üst yüzey sertlik oranlarına etkisinin, tepilebilir bir kompozit reçine ile karşılaştırmalı olarak incelenmesidir. Venüs Bulk Fill, SonicFill ve kontrol grubu olarak Solitaire 2 kompozit materyalleri kullanıldı. Her bir materyalden hazır metal kalıplar kullanılarak, farklı yüksekliklerde (kontrol grubu 2 mm) silindirik numuneler hazırlandı (n=7; 8 mm çapında, 2, 4 ve 5 mm yüksekliğinde). Halojen ve LED ışık cihazları ile 20 sn ve 40 sn süre ile polimerize edildi. Numunelerin ışık uygulanan üst yüzeylerine cila diskleri ile polisaj yapıldı ve numuneler sertlik ölçümü öncesinde 37º C'de 24 saat distile suda bekletildi. Bekleme süresi sonrasında, numunelerin alt ve üst yüzeylerinden Vicker's sertlik cihazı ile 1 mm aralıklarla 3'er ölçüm yapıldı ve her bir numunenin alt/ üst yüzey sertlik oranları belirlendi. Elde edilen veriler, tek yönlü varyans (one-way ANOVA) analizi ve çoklu karşılaştırmalarda Tukey HSD testi ile analiz edildi (p<0.05). Bulk fill kompozit reçineler her iki ışık cihazında, ışık uygulama sürelerinde ve tüm yüksekliklerde %80 üzerinde alt/üst yüzey sertlik değişim oranı gösterirken, Solitaire 2 ışık uygulama süresine bakılmaksızın sadece LED ışık cihazının kullanıldığı gruplarda %80'in üzerinde alt/üst yüzey sertlik değişim oranı gösterdi. Kompozit reçine tipine, uygulama yüksekliğine ve ışık uygulama süresine bakılmaksızın, LED ışık cihazı halojen ışık cihazına göre istatistiksel olarak anlamlı derecede daha yüksek sertlik değişim oranları gösterdi (p<0.001). Polimerizasyon sürelerinin, farklı yükseklikteki numunelerin sertlik değişim oranları üzerine istatistiksel olarak anlamlı bir etkisi gözlenmedi (p>0.05). Bulk kompozit reçineler tüm uygulama yüksekliklerinde, ışık uygulama sürelerinde ve ışık cihazlarında klinik olarak kabul edilen minimum %80 değerinin üzerinde alt/üst yüzey sertlik oranları göstermiştir.

Özet (Çeviri)

The purpose of this study was to investigate the influence of different increment thickness, curing times and light curing unit types on the bottom/top microhardness ratio of different bulk fill composites in comparison with a packable resin composite. Bulk fill composites; Venus Bulk Fill and SonicFill were tested and, Solitaire 2 was used as control. For each bulk fill material different incremental thicknesses (8 mm diameter, 2, 4 and 5 mm height) and only 2 mm thick specimens were prepared for the control group (n=7 per group). Specimens were light cured for 20 s and 40 s using a quartz-tungsten-halojen and LED light curing units (LCUs). The top surfaces of the specimens were polished with aluminum oxide polishing discs and then stored in distilled water at 37 °C for 24 h before hardness measurement. After storage period, three measurements were recorded at the top and at the bottom surfaces on each sample by Vickers hardness tester and the bottom/top hardness ratio measurements were recorded. The data were statistically analyzed by One-way ANOVA, Tukey HDS tests (p<0.05). While Bulk fill resin composites tested showed more than 80% hardness ratio in both curing unit, irradiation times and in all increment thickness, whereas, Solitaire 2 demonstrated more than 80% hardness ratio only when the LED LCU used regardless of the light curing time. Among the specimens that were polymerized with LED LCU demonstrated significantly higher bottom/top hardness ratio than QTH lamp, irrespective of the thickness, curing time, and material type (p<0.001). No significant effect of polymerization times on the hardness changes of different thickness specimens were observed (p>0.05). Bulk fill resin composites have demonstrated clinically acceptable minimum threshold level of 80% bottom/top hardness ratio in all increment thickness, in all curing time and curing units.

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  2. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    ÜrolojiGazi Üniversitesi

    Üroloji Ana Bilim Dalı

  3. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Besin Hijyeni ve Teknolojisiİstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    DOÇ. DR. TÜRKAN KUTLUAY