Kombine headgearlerde oluşturulan farklı kuvvet vektörlerinin iskeletsel ve dentoalveolar yapılar üzerine etkilerinin incelenmesi
The Investigation of the effect of different vectors of forces applied by combined headgears on skeletal and dentoalveolar structures
- Tez No: 48977
- Danışmanlar: DOÇ.DR. SEMA YÜKSEL
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 1995
- Dil: Türkçe
- Üniversite: Gazi Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Belirtilmemiş.
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 118
Özet
105 SUMMARY Combined headgear was used for upper molar distalization in the treatment of Class II malocclusion. The purpose of this study was to evaluate the effects of different vectors of forces applied by combined headgear on skeletal and dentoalveolar structures. The study material consisted of 30 patients with Class II dental relationships and steep mandibular plane angle. All patients were matched according to their ANB, SN/Go-Gn angles and skeletal ages.so three groups were constructed with 10 patients in each group.The average skeletal ages were 10 years 6 months for the first treatment group, 10 years 2 months for the second treatment group,10 years 1 months for the third treatment group. Lateral cephalograms, anteroposterior, basiler and hand- wrist radiographs were taken before and after treatment. All of the patients were treated with extraoral combined traction to the maxillary first molars. In the first treatment group a force of 150 grams per side was adjusted for the highpull component and of 150 grams per side for the cervical component. In the second treatment group force adjustment was made as 200 grams per side for the highpull component and 100 grams per side for the cervical component and in the third treatment group a force of 100 grams per side was adjusted for the highpull component and of 200 grams per side for the cervical component. The patients were instructed to wear the appliance 20 hours per day until the molar relationship was106 corrected. The treatment time was between 2 and 9 months for the first group, 3 and 7 months for the second group, 2 and 7 months for the third group. 85 parameters obtained from the lateral cephalograms, anteroposterior and basiler radiographs that was taken before and after the treatment, were evaluated. Statistical analysis were made to determine the changes that occurred during treatment, the differences between the groups and the correlations between the upper first molar vertical displacement and the dento-skeletal parameters. Molar distalization was achieved by different vectors of forces applied by combined headgear. Changes in the direction of pull were effective on upper first molar tipping degree and vertical displacement. Also by the evaluation of occlusal and mandibular plane angles, significant differences between the groups were observed. It was obvious that for the individuals showing vertical growth tendencies occipitally directed forces applied by combined headgear were more convinient compared to other types of force systems used in this study.
Özet (Çeviri)
105 SUMMARY Combined headgear was used for upper molar distalization in the treatment of Class II malocclusion. The purpose of this study was to evaluate the effects of different vectors of forces applied by combined headgear on skeletal and dentoalveolar structures. The study material consisted of 30 patients with Class II dental relationships and steep mandibular plane angle. All patients were matched according to their ANB, SN/Go-Gn angles and skeletal ages.so three groups were constructed with 10 patients in each group.The average skeletal ages were 10 years 6 months for the first treatment group, 10 years 2 months for the second treatment group,10 years 1 months for the third treatment group. Lateral cephalograms, anteroposterior, basiler and hand- wrist radiographs were taken before and after treatment. All of the patients were treated with extraoral combined traction to the maxillary first molars. In the first treatment group a force of 150 grams per side was adjusted for the highpull component and of 150 grams per side for the cervical component. In the second treatment group force adjustment was made as 200 grams per side for the highpull component and 100 grams per side for the cervical component and in the third treatment group a force of 100 grams per side was adjusted for the highpull component and of 200 grams per side for the cervical component. The patients were instructed to wear the appliance 20 hours per day until the molar relationship was106 corrected. The treatment time was between 2 and 9 months for the first group, 3 and 7 months for the second group, 2 and 7 months for the third group. 85 parameters obtained from the lateral cephalograms, anteroposterior and basiler radiographs that was taken before and after the treatment, were evaluated. Statistical analysis were made to determine the changes that occurred during treatment, the differences between the groups and the correlations between the upper first molar vertical displacement and the dento-skeletal parameters. Molar distalization was achieved by different vectors of forces applied by combined headgear. Changes in the direction of pull were effective on upper first molar tipping degree and vertical displacement. Also by the evaluation of occlusal and mandibular plane angles, significant differences between the groups were observed. It was obvious that for the individuals showing vertical growth tendencies occipitally directed forces applied by combined headgear were more convinient compared to other types of force systems used in this study.
Benzer Tezler
- Kombine ekmek katkı maddesi geliştirilmesi üzerinde araştırma
Study on the improving of combined bread addivite
TÜLİN DAĞALP
Yüksek Lisans
Türkçe
1999
Gıda MühendisliğiAnkara ÜniversitesiGıda Mühendisliği Ana Bilim Dalı
PROF. DR. RECAİ ERCAN
PROF. DR. S. SEZGİN ÜNAL
PROF. DR. ALİ ALTAN
- Kombine spinal epidural anestezide bupivacain ve ketamin kullanımı
Bupivacain and ketamin using in combined spinal-epidural anesthesia
TEKİN AKÇA
Tıpta Uzmanlık
Türkçe
1998
Anestezi ve ReanimasyonDicle ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DOÇ. DR. DEMET TOK
- Efficiency evaluation of combined cycle power plants
Kombine çevrim enerji santralları verimlerinin incelenmesi
EMRAH ARICA
Yüksek Lisans
İngilizce
1998
Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
PROF. DR. OSMAN SEVAİOĞLU
- Kombine elektrikli ve güneş enerjili yemek pişirme cihazının tasarım ve imalatı
Başlık çevirisi yok
ZEKİ TAHİROĞLU
Yüksek Lisans
Türkçe
1998
Eğitim ve ÖğretimMarmara ÜniversitesiMakine Eğitimi Ana Bilim Dalı
DOÇ. DR. A. KORHAN BİNARK
- Kombine Lomber pleksus ve Siyatik sinir bloğu yapılan alt ekstremite cerrahilerinde blok kalitesinin değerlendirilmesinde Perfusion index (Pi), Near İnfrared Spectroscopy (NRSI), ve Noninvaziv total hemoglobin monitörizasyonu (SpHB) yöntemlerinin karşılaştırılması
Evaluation of block quality using Near Infrared Spectroscopy (NIRS), Perfusion index (Pi) and Noninvasive monitoring of total hemoglobin (SpHB) in lower extremity surgery for combine lumbar plexus and sciatic nerve block
SUAT KARATAŞ
Tıpta Uzmanlık
Türkçe
2022
Anestezi ve ReanimasyonHarran ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DOÇ. DR. AHMET ATLAS