Web tabanlı radyasyon kayıt ve takip sistemi üretimi

Web based radiation track and record system design

  1. Tez No: 494366
  2. Yazar: OZAN GÜMÜŞ
  3. Danışmanlar: YRD. DOÇ. DR. AYŞEGÜL YURT, YRD. DOÇ. DR. KADİR AKGÜNGÖR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Fizik ve Fizik Mühendisliği, Radiology and Nuclear Medicine, Physics and Physics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Kamu ve Özel hastaneler bünyesinde bulunan Radyoloji, Nükleer Tıp, Radyasyon Onkolojisi gibi radyasyon ile çalışılan alanlarda ortam radyasyon dozunun anlık olarak ölçülerek takip edilmesi, ölçüm sonuçlarına uzaktan erişim sağlanması ve elde edilen verilerin kayıt edilebilmesiyle geçmişe dönük sorgulama yapabilecek bir sistem üretmektir. Sistem tasarımında dedektör olarak Geiger - Müller tüpü kullanıldı. Elektronik kart tasarımı EAGLE FREEWARE elektronik kart tasarım programıyla çizilip, üretildi. Üretilen elektronik kartın montajı tamamlandıktan sonra cihazın mikroişlemcisi, grafik arayüzü ve web arayüzü programlandı. Sistem tasarımı tamamlandıktan sonra; kalibrasyonu yapılmış Radyasyon Alan Monitörü ile beraber dönüşüm katsayısı hesabı için 10cm aralıklar ile 10 – 120 cm aralığında, eş zamanlı ölçüm yapıldı, açı bağımsızlığını tespit etmek için 22.5° 'lik açılar ile ölçümler alınarak her bir açı değeri için standart sapmalar hesaplandı ve enerji bağımsızlığını ölçmek için Co-57, Ba-133, Cs-137 ile farklı dedektör – kaynak mesafelerinde ölçüm alındı. Farklı dedektör – kaynak mesafelerinde yapılan ölçümler sonucunda geliştirilen cihazın ölçüm birimi olan cps, R/h'a çevrilebilmesi için gereken dönüşüm katsayısı 0.0044 olarak hesaplandı. Açı bağımsızlığı testinde herbir açı değeri için hesaplanan en büyük değer %4.04, en küçük değer %0,51 olarak hesaplandı. Geliştirilen sistemin dozimetrik ölçüm sonuçları mevcut kullanılan sistemlerin ölçüm sonuçları ile uyumlu olduğu gözlemlendi.

Özet (Çeviri)

It is to produce a system capable of monitoring of the radiation dose of the environment instantaneously radition fields such as Radiology, Nuclear Medicine, Radiation Oncology etc. which are located in public and private hospitals, providing remote access to the measurement results and recording the obtained data to produce a system that can perform retrospective inquiry. Geiger Müller tube was used as detector in System Design. Electronic card design was drawn and produced with EAGLE FREEWARE electronic card design software. After the assembly of the produced electronic card is completed, the microprocessor, graphic interface and web interface of the device are programmed. After system design is completed; simultaneous measurements were made in the range of 10 - 120 cm with 10 cm intervals for the conversion coefficient account together with the calibrated Radiation Field Monitor, in order to measure energy independence, measurements were taken at different detector – source distances with Co-57, Ba-133, Cs-137. Cps, which is the measuring unit of the device developed as a result of measurements made at different detector-source distances, was calculated as 0.0044, which is required to convert it to R/h. In the angle independence test, the maximum value calculated for each angle value was calculated as 4.04% and the smallest value as 0.51%. It is observed that the existing systems are compatible with the measurement results according to the values obtained as a result of the dosimetric measurements of the developed system.

Benzer Tezler

  1. Samsun ve çevresinde tarla sarmaşığı (conuolvulus arvensis L.)'na karşı biyolojik savaşa esas olacak fauna tespiti

    Investigations on the insect fauna of the field binweed (Conuolvulus arvensis L.) related to its biological control in Samsun Province

    YASEMİN UFUK GERMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bitki Koruma Ana Bilim Dalı

    Yükleniyor...

  2. 1,3-difenil-4,5-bis(hidroksiimino)-imidazolidin ve Ni(II), Cu(II), Pd(II), UO2(VI) komplekslerinin sentezi

    Başlık çevirisi yok

    VEFA AHSEN

    Doktora

    Türkçe

    Türkçe

    1984

    Uludağ Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Tekstil boyamacılığında atık flottede boyama imkanları üzerine araştırma

    Başlık çevirisi yok

    MEHMET YAKARTEPE

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Travmatik erkek paraplojelere yüksek frekanslı TENS

    Başlık çevirisi yok

    SEMA ÖZTÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Kazalarda Acil Yardım ve Rehabilitasyon Ana Bilim Dalı

    Yükleniyor...

  5. Boğazdan izole edilen coliform bakterilerin B- laktamaz enzim aktivitelerinin tesbit edilmesi ve B-laktamaz pozitif coliformların penisilinetkisinin inaktivasyonunun in vitro deneylerle gösterilmesi

    The Detection of beta-lactamasa activity of coliform bacteria isolated from th roat cultures and slovving the inactivation of penicilin by this beta lactamase produced by this caliform organisms

    GÜVEN URAZ

    Doktora

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Genel Biyoloji Ana Bilim Dalı

    Yükleniyor...