Gama kameranın hassasiyet ve sayım veriminin silindirik kaynak geometrisinde incelenmesi

Investigation on the sensitivity and the counting efficiency of a gamma camera in cylindrical source geometry

  1. Tez No: 523408
  2. Yazar: RUKİYE ÇAKIR HALİLOĞLU
  3. Danışmanlar: PROF. DR. ÖZLEM KARADENİZ, PROF. DR. HATİCE DURAK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 73

Özet

Amaç: Sayım verimi ve hassasiyet, nükleer tıpta görüntüleme uygulamalarında kullanılan gama kameraya ait iki karakteristik özelliktir. Sayım verimi ve hassasiyet belirlenirken pratik olması açısından detektörden belirli uzaklığa yerleştirilmiş noktasal bir radyasyon kaynağı kullanılır. Fakat gerçekte hasta ve noktasal radyasyon kaynağı aynı geometride olmadıklarından, bu yöntemin klinik uygunluk bakımından dezavantajı vardır. Bu çalışmada, bir gama kameranın sayım veriminin ve hassasiyetinin silindirik bir kaynak kullanılarak saptanması ve artan kaynak kalınlığı ile saçılma oranlarındaki değişimlerin incelenmesi amaçlanmıştır. Yöntem: Bir gama kameranın sayım verimi ve hassasiyeti; 4 mCi aktiviteli ve 2-18 cm kalınlığında homojen 99mTc kaynağı ile LEGP ve LEHR kolimatörleri kullanılarak, kısa kaynak – dedektör mesafelerinde (5-25 cm) belirlenmiştir. Hesaplamalar asimetrik pencere (133–153 keV) ve bu enerji aralığındaki sayımlar dikkate alınarak yapılmıştır. Saçılan radyasyon etkileri hem 99mTc enerji spektrumuna bağlı saçılma oranlarının analizi hem de sayım verimi ve hassasiyet grafikleri çizilerek değerlendirilmiştir. Bulgular: Saçılma oranı değerleri artan kaynak kalınlığıyla LEHR kolimatör için 0,19' dan 4,52' ye ve LEGP kolimatörü için 0,27' den 4,62' ye artış göstermiştir. Artan kaynak kalınlığıyla kamera hassasiyetinin LEHR kolimatör için 55 sayım/(sMBq)'den 24 sayım/(sMBq)'e azalırken, LEGP kolimatör için 98 sayım/(sMBq)'den 41 sayım/(sMBq)'e azaldığı saptanmıştır. Sayım verimi artan kaynak kalınlığı ile LEHR kolimatör için, % 0.19'dan % 0.08'e ve LEGP kolimatör için % 0.35'den % 0.14'e azalmaktadır. Hesaplanan sayım verimi kaynak - dedektör mesafesinin artmasıyla LEHR kolimatör için % 0,19' dan % 0,54'e ve LEGP kolimatör için ise % 0,35' den % 0,97' ye artmıştır. Sonuç: Araştırmada, saçılma oranı değerleri artan kaynak kalınlığı ile artmıştır. Hesaplanan kamera hassasiyeti, kaynak kalınlığı ve kaynak - dedektör mesafesinin artmasıyla azalan bir eğilim göstermiştir. Sayım verimi, kaynak kalınlığının artmasıyla azalmakta ve kaynak- dedektör mesafesinin artmasıyla orantılı olarak da artmaktadır. Kaynak - dedektör mesafesinin artması sayım veriminin artmasıyla, fakat kamera hassasiyetinin azalması ile sonuçlanmıştır.

Özet (Çeviri)

Purpose: The counting efficiency and the sensitivity are two important characteristic properties of a gamma camera used in nuclear medicine imaging. Because of practical reasons, counting efficiency and the sensitivity have been characterized with a point source of radiation at a certain distance from the detector. However this way has the disadvantage of producing measurements of limited clinical relevance since real patients are not point sources of radiation. In this work, it was aimed to determine the counting efficiency and sensitivity of a gamma camera with a cylindrical source and to investigate the variation of scatter contribution with increasing source thickness. Methods: The counting efficiency and sensitivity of a dual-head clinical gamma camera were determined using homogeneous 99mTc source thickness of 2–18 cm and an activity of 4 mCi at small source–detector distances (5–25 cm) for both LEGP and LEHR collimators. The energy spectra were acquired. The asymmetric window (133–153 keV) was considered and the counts in this energy window were integrated. Scattered radiation effect was evaluated by both analyzing the energy spectrum of 99mTc for the scatter fraction and plotting the counting efficiency and sensitivity. Results: The scattered fraction values increased with increasing source thickness from 0,19 to 4,52 and from 0,27 to 4,62 for LEHR and LEGP collimator. Calculated sensitivity decreased with increasing source thickness, from 55 counts/sMBq to 24 counts/sMBq and from 98 counts/sMBq to 41 counts/sMBq for LEHR and LEGP collimator. The efficiency decreases with increasing source thickness, from 0,19 % to 0,08 % and from 0,35 % to 0,14 % for LEHR and LEGP collimator. Calculated efficiency increased with increasing source-to-detector distance, from 0,19 % to 0,54 % and from 0,35 % to 0,97 % for LEHR and LEGP collimator. Conclusions: The scattered fraction values increased with increasing source thickness. Calculated sensitivity shows a decreasing trend with increasing source thickness and increasing source-to-detector distance. The efficiency decreases with increasing source thickness and efficiency increases with increasing source to detector distance. Increasing source to detector distances results with increasing counting efficiency but decreasing sensitivity.

Benzer Tezler

  1. Design of a collimator for breast-specific gamma imaging and assessment of NEC rate for a pet scanner using Monte Carlo simulations and response surface methodology

    Monte Carlo benzetimleri ve tepki yüzey metodu kullanılarak meme-spesifik gama görüntüleme için kolimatör tasarımı ve bir pet tarayıcı için NEC hızı değerlendirmesi

    DİDAR TALAT

    Doktora

    İngilizce

    İngilizce

    2016

    BiyomühendislikBoğaziçi Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ALBERT GÜVENİŞ

  2. Motorize kama ile alan-içi-alan tekniklerinin yüksek enerjili x-ışını demetlerindeki davranışlarının dozimetrik karşılaştırılması

    Dosimetric comparisonof behavior motorised wedge and field-in-field techniques in high-energy x-ray beams

    HASAN YENER

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Fizik ve Fizik MühendisliğiMustafa Kemal Üniversitesi

    Fizik Ana Bilim Dalı

    YRD. DOÇ. DR. SİNAN YAŞAR

  3. Development of a phantom for quali̇ty control of a gamma camera

    Gama kameranın kalite kontrolü için bir fantom geliştirilmesi

    ALIO AHMAT OUMAR

    Doktora

    İngilizce

    İngilizce

    2020

    Elektrik ve Elektronik MühendisliğiGaziantep Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. ERGUN ERÇELEBİ

  4. Sintigrafide Gama kamera ile kaynak doku mesafesinin görüntü kalitesine etkisinin kemik lezyonu modellemesi ile incelenmesi

    Analyzing the effect of distance between the source of tissue and the colimator on the image quality at the scintigrapic image gained via Gamma camera with the modeling of bone lesion

    ERKAN SEZGİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Radyoloji ve Nükleer TıpEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    PROF. DR. MEHMET NURULLAH KUMRU

  5. Simulation of gamma camera in Yeditepe university hospital with gate

    Yeditepe üniversitesi hastanesine ait gama kamera cihazının gate ile simülasyonu

    GÜLÇİN İRİM

    Yüksek Lisans

    İngilizce

    İngilizce

    2013

    Fizik ve Fizik MühendisliğiYeditepe Üniversitesi

    Fizik Bölümü

    DOÇ. DR. ŞERİFE İPEK KARAASLAN