El bileği eklemi propriyosepsiyon ölçümü için kullanılan üç farklı yöntemin geçerliğinin ve güvenirliğinin karşılaştırılması
Comparison of the validity and reliability of three different methods used for wrist proprioception measurement
- Tez No: 535361
- Danışmanlar: DOÇ. DR. DERAN OSKAY
- Tez Türü: Yüksek Lisans
- Konular: Fizyoterapi ve Rehabilitasyon, Physiotherapy and Rehabilitation
- Anahtar Kelimeler: El Bileği, Propriyosepsiyon, İnklinometre, Gonyometre, İzokinetik, Bilek, Bilek eklemi, Güvenilirlik ve geçerlilik, Ölçüm yöntemleri, Ölçümleme, Wrist, Proprioception, Inclinometer, Goniometer, Isokinetic, Wrist joint, Reproducibility of results, Measurement methods, Measurement
- Yıl: 2018
- Dil: Türkçe
- Üniversite: Gazi Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Fizyoterapi ve Rehabilitasyon Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Çalışmamızın amacı; el bileği eklemi propriyosepsiyon ölçümünde kullanılan gonyometre, inklinometre ve eklem pozisyon hissi gonyometresi (EPHG) yöntemlerinin geçerliklerini ve güvenirliklerini karşılaştırmaktır. Gereç-Yöntem: Çalışmaya, 19-31 yaşları arasında, toplam 32 gönüllü sağlıklı katılımcı (64 el bileği) (Yaş; 23,2 ± 3,84) dahil edildi. Propriyosepsiyon için aktif eklem pozisyon hissi (EPH) değerlendirildi. Öncelikle katılımcılara üç kez hedef açı öğretildi ve daha sonra katılımcılardan bu açıyı 3 kez bulmaları istendi. Hedef açı ile getirilen açı arasındaki hata miktarı aktif EPH'nin doğruluğunu tanımlamak için kullanıldı. Gonyometre, inklinometre ve EPHG değerlendirmeleri için aynı protokol uygulandı. Test tekrar test güvenirliğine bakmak amacıyla aynı ölçümler 7 gün sonra tekrar edildi. İstatistiksel analiz SPSS 22 yazılımı kullanılarak yapıldı. Geçerlik analizi Spearmen testi, test tekrar test sonuçları Intraclass Correlation Coefficient (ICC) testi kullanılarak analiz edildi. Bulgular: Yapılan analizler sonucunda Gonyometre (p<0,001, r;0,529), EPHG (p<0,001 r;0,432) ve inklinometre (p;0,005, r:0,350) yöntemlerinin el bileği EPH değerlendirmesinde geçerli oldukları bulunmuştur. Yapılan ICC testi sonuçlarına göre; İnklinometre (p;0,183, ICC;0,114) el bileği EPH değerlendirmesi için güvenilir değilken, gonyometre (p<0,001 ICC; 0,422) ve EPHG (p;0,001, ICC;0,369) güvenilir olarak bulundu. Sonuç: El bileği EPH değerlendirmesinde hem geçerli hem de güvenilir bulduğumuz gonyometre ve EPHG'si kliniklerde ve araştırmalarda kullanılabilir ancak inklinometre geçerli çıkmasına rağmen yeterli güvenirliğe sahip olmadığından bu değerlendirme için kullanılmamasını öneriyoruz.
Özet (Çeviri)
Aim: The purpose of our study was to compare the validity and reliability of the goniometer, inclinometer and joint position sense goniometer (JPSG) methods used in measuring wrist proprioception. Method: 32 volunteer healthy participants (64 wrists) (Age: 23,2 ± 3,84) between the ages of 19-31 were included in the study. Active joint position sense (JPS) was assessed to evaluate proprioception sense. Firstly, the target angle was taught to participants three times before joint position sense evaluation and then the patient was asked to find this angle for three times. The amount of error between the target angle and the angle that was found by the participant was used to define the correctness of the active joint position sense. The same protocol was applied for goniometer, inclinometer and JPSG evaluations. These assessments were repeated 7 days after to exam the test-retest reliability. Statistical analysis was performed by using SPSS 22 software. Spearman's Correlation Coefficient was used for validity analysis and Intraclass Correlation Coefficient (ICC) was used for the test-retest reliability analysis. Results: As a result of the analyzes, it was found that goniometer (p <0.001, r; 0.529), JPSG (p <0.001 r; 0.432) and inclinometer (p: 0.005, r: 0.350) have validity for wrist JPS assessment. According to the results of ICC analyzes; goniometer (p <0.001, ICC; 0.422) and JPSG (p; 0.001, ICC; 0.369) were found to be reliable methods to assess JPS while the inclinometer (p;0,183, ICC;0,114) was not. Conclusion: The goniometer and EPHG that we find both valid and reliable in wrist JPS evaluation, can be used in clinics and researches. However, since the inclinometer does not have sufficient reliability despite its validity, we recommend that it should not be used for this evaluation.
Benzer Tezler
- Romatoid artrit hastalarında kinezyofobi, propriosepsiyon, kas kuvveti, fonksiyon, fiziksel aktivite ve hastalık aktivitesi arasındaki korelasyonlar
Corelations between kinesiophobia, proprioception, muscle strenght, function, physical activity and disease activity in rheumatoid arthritis patients
SEMİHA ARPAGUŞ
Yüksek Lisans
Türkçe
2024
Fizyoterapi ve RehabilitasyonSivas Cumhuriyet ÜniversitesiFizik Tedavi ve Rehabilitasyon Ana Bilim Dalı
DOÇ. DR. SELVİN BALKİ
PROF. DR. METİN ÖZGEN
- İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar
Başlık çevirisi yok
BAHAR TÜRKYILMAZ
Yüksek Lisans
Türkçe
1985
Şehircilik ve Bölge PlanlamaEge ÜniversitesiŞehir ve Bölge Planlama Ana Bilim Dalı
- Bazı sert çekirdekli meyve türlerinde döllenme biyolojisi üzerinde yöntem çalışmaları
Başlık çevirisi yok
ATBİMOĞLU ADALET
- Kuyruk modelleri ve analizi üzerine bir uygulama
Başlık çevirisi yok
DİDEM ÖZPULAT
Yüksek Lisans
Türkçe
1985
İstatistikEge ÜniversitesiBilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı
DOÇ. DR. FİKRET İKİZ