Geri Dön

CAD/CAM sistemleri ile elde edilen monolitik zirkonyanın farklı aşındırma prosedürleri sonrası biaksiyel bükme dayanımının in vitro olarak incelenmesi

In vitro evaluation of the biaxial flexural strength of monolithic zirconia fabricated with CAD/CAM systems after different grinding procedures

  1. Tez No: 535779
  2. Yazar: AYÇA ÇAŞUR
  3. Danışmanlar: PROF. DR. ÖZLEM MALKONDU
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Aşındırma, CAD/CAM, Dental materyaller, Dental porselen, Dental stres analizi, Yüzey pürüzlülüğü, Zirkonyum oksit, Abrasion, CAD/CAM, Dental materials, Dental porcelain, Dental stress analysis, Surface roughness, Zirconium oxide
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Monolitik zirkonya, veneerlenen porselenin kırılma risklerini elimine etmesi sebebiyle kuron ve köprü restorasyonlarında sıklıkla kullanılmaktadır. Ancak bu materyallerin CAD/CAM sistemleri ile üretilmiş olmalarına rağmen, klinikte uyumlandırma işlemlerine ihtiyaç duyulmaktadır. Hızlı ve yavaş dönme özelliğine sahip döner aletler ile farklı frez çeşitleri kullanılarak sulu ve susuz ortamda uygulanan aşındırma prosedürleri klinisyenler tarafından sıklıkla kullanılmaktadır. Çalışmamızın amacı; monolitik zirkonya materyallerinin aşındırma prosedürleri sonrasında değişen mekanik özelliklerinin değerlendirilmesidir. Deney grupları için, monolitik zirkonya bloklarından (Amann Girbach-Ceramill Zolid White, Zirkonzahn-Prettau,GC-Inıtıal Zr Disk) merkezinde 3 mm çapında, 1 mm yüksekliğinde özel silindir dizaynı bulunan, 15 mm çapında, 1.2 ± 0.2 mm yüksekliğinde disk şeklinde örnekler hazırlanmıştır. Kontrol grupları için ise, merkezde özel silindir dizaynı mevcut değildir. Aerotor ve mikromotor ile 3 farklı frez çeşidi (Meisinger 881Z4 (medium), Meisinger Z732 (medium), Meisinger 640 (medium)) kullanılarak sulu ve susuz ortamda merkezdeki silindir kaybolana kadar aşındırma işlemleri uygulanmıştır ve sıcaklık değerleri kaydedilmiştir. Aşındırma sonrasında ise; yüzey pürüzlülük değerleri ölçülüp, materyaller biaksiyel bükme testine tabi tutulup, vickers mikrosertlik testi uygulanmıştır. Verilerin değerlendirilmesinde tanımlayıcı istatistiksel metotların (ortalama,standart sapma), yanı sıra normal dağılım gösteren değişkenlerin zaman karşılaştırmalarında eşlendirilmiş tek yönlü varyans analizi, alt grup karşılaştırmalarında Newman Keuls çoklu karşılaştırma testi, gruplar arası karşılaştırmalarda tek yönlü varyans analizi, alt grup karşılaştırmalarında Tukey çoklu karşılaştırma testi, ikili grupların karşılaştırmasında bağımsız t testi, kullanılmıştır. Sonuçlar, anlamlılık p<0,05 düzeyinde değerlendirilmiştir. Çalışmamızın sonuçları değerlendirildiğinde, tüm monolitik zirkonya bloklarında işlem görmemiş kontrol gruplarının pürüzlülük ortalamaları, aşındırma yapılmış tüm deney gruplarının pürüzlülük ortalamalarından istatistiksel olarak anlamlı derecede düşük bulunmuştur. Sulu ve susuz ortamda her üç monolitik zirkonya bloğunda da aerotor ile 881Z4 frezinin kullanıldığı grupların yüzey pürüzlülük ortalamaları, diğer deney ve kontrol gruplarından istatistiksel olarak anlamlı derecede yüksek bulunmuştur. Biaksiyel bükme dayanımları değerlendirildiğinde ise, 3 monolitik zirkonya materyalinde de (Amann Girbach, Zirkonzahn, GC) frez çeşidi farketmeksizin susuz ortamda aşındırma işlemi uygulanan deney gruplarının biaksiyel bükme dayanımı, sulu ortamda aşındırma işlemi uygulanan deney gruplarından daha düşük ortalama değerlere sahiptir. Tüm monolitik zirkonya materyallerinde sulu ve susuz ortamda, deney gruplarının biaksiyel bükme dayanımları arasında istatistiksel olarak anlamlı farklılık gözlemlenmemiştir. Çalışmamızda susuz ortamda en yüksek sıcaklık ortalaması 104,23±13,27 oC, sulu ortamda ise 27,91±1,84 oC olarak ölçülmüştür. Tüm monolitik zirkonya materyallerinde (Amann Girbach, Zirkonzahn,GC), sulu ve susuz ortamda aerotor ile 881Z4 frezinin kullanıldığı deney gruplarının vickers mikrosertlik ortalamaları, diğer deney gruplarından anlamlı derecede yüksek bulunmuştur.

Özet (Çeviri)

Monolithic zirconia is frequently used in crown and bridge restorations by eliminating the risks of chipping of the veneered porcelain However, although these materials are produced by CAD/CAM systems, clinical adjustment still necessary. Grinding procedures are frequently apply by clinicians using high-speed and low-speed rotary instruments with different types of burs with or without water cooling. The purpose of this study is to evaluate the changing mechanical properties of monolithic zirconia materials after grinding procedures. Disk-shaped specimens (15 mm in diameter and 1.20± 0.2 mm in height) with a smaller cylinder at the center of the each disk (3 mm in diameter and 1 mm in height) were prepared by using monolitihic zirconia materials (Amann Girbach-Ceramill Zolid White, Zirkonzahn-Prettau, GC-Inıtıal Zr Disk) for the experimental groups. For the control groups, there were no special cylinder design at the center. Grinding procedures were applied by using 3 different type of burs (Meisinger 881Z4 (medium) , Meisinger Z732 (medium), Meisinger 640 (medium)) with and without water cooling until the cylinder at the center lost it's thickness during this process and the temperature values were recorded. After grinding, the surface roughness values were measured and the material was subjected to biaxial flexural test and vickers microhardness test. One-way variance analysis is used in comparisons of variables, Newman Keuls multiple comparison test in sub-group comparisons, one-way variance analysis in cross-group comparisons, Tukey multiple comparison test in sub-group comparisons, independent t-test in comparison of binary groups were used. The results were evaluated at p<0.05 level. When the results of our study were evaluated, the roughness averages of the untreated control groups were statistically lower than the roughness averages of all the experimental groups. The mean roughness values of the groups in which the aerotor and 881Z4 bur used in all conditions (with and without water cooling) were found to be significantly higher than the other experimental and control groups. When the biaxial flexural strengths were evaluated, the biaxial flexural strength of the experimental groups in which the grinding process was applied without water cooling had lower mean values than the experimental groups that the grinding process was applied under water cooling. In all monolithic zirconia materials, there was no statistically significant difference between the biaxial flexural strengths of experimental groups in all conditions (with and without water cooling). In our study, the highest temperature values without water cooling was measured 104,24 ± 13,27 oC and with water cooling was measured 27,91 ± 1,84 oC. In all monolithic zirconia materials, the vickers microhardness values of experimental groups which were grinded with aerotor and 881Z4 burs in all condition (with and without water cooling) were found to be significantly higher than the other experimental groups.

Benzer Tezler

  1. CAD/CAM sistemleriyle üretilmiş iki yarı saydam, monolitik zirkonya restorasyonun klinik uyumlama prosedürlerinin materyalin optik ve mekanik özelliklerine etkilerinin değerlendirilmesi

    Evaluation of the effects of clinical adaptationprocedures of two translucent, monolithic zirconium restoration manufacturedwith the use of CAD/CAM systems on the optical and mechanical properties of thematerial

    CANSU TOR

    Doktora

    Türkçe

    Türkçe

    2022

    Diş HekimliğiBiruni Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SAİP DENİZOĞLU

    DR. ÖĞR. ÜYESİ EMİN ORKUN OLCAY

  2. İmplant destekli sabit protezlerde CAM/CAM sistemleri ile üretilen destek ve üst yapı restorasyonlarının sonlu elemanlar stres analiz yöntemi ve kırılma direnci testi ile karşılaştırmalı olarak incelenmesi

    The comparatively investigation of abutment and crown restorations produced by CAD/CAM systems in implant supported fixed prostheses using the finite element stress analysis method and fracture resistance test

    NAZİRE ESRA BAĞDATLI

    Doktora

    Türkçe

    Türkçe

    2016

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. AHMET ERSAN ERSOY

  3. Farklı yapıdaki zirkonya seramiklerin yapay yaşlandırma sonrası sertlik ve kırılma mukavemetlerinin mikroyapı analizi ile incelenmesi

    Evaluation of hardness and fracture strength properties of different zirconia types using microstructural analysis following artificial aging

    ENGİN TÜRKMEN

    Doktora

    Türkçe

    Türkçe

    2019

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. MAHİR MURAT AYDIN

  4. Farklı adeziv sistemler kullanılarak yapılan immediate dentin sealing (hemen dentin kapama) işleminin monolitik zirkon blokların dentine olan bağlanma dayanımı üzerine etkisi

    The effect of immediate dentin sealing procedure using different adhesive systems on the bond strength of monolithic zirconia to dentin

    LEYLA FAZLIOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiBezm-İ Alem Vakıf Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. BURCU OĞLAKÇI

  5. Simante ve farklı koniklik açılarına sahip konometrik abutmentların termomekanik yaşlandırma sonrası retansiyonlarının karşılaştırılması

    Comparison of retention of cemented and conometric abutments with different taper angles following thermomechanical aging

    TUĞÇE KOÇ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2026

    Diş HekimliğiTokat Gaziosmanpaşa Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. IŞIL SARIKAYA