Geri Dön

Farklı apeks bulucu sistemlerin farklı irrigasyon solüsyonları varlığında kök perforasyonlarını belirlemedeki doğruluğunun değerlendirilmesi

Evaluation of different apex finder systems for determination of root perforations in presence of different i̇rrigation solutions

  1. Tez No: 547679
  2. Yazar: OĞUZ BURHAN ÇETİNKAYA
  3. Danışmanlar: DOÇ. UĞUR AYDIN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Gaziantep Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Endodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 104

Özet

Geçmişten günümüze elektronik apeks bulucular (EAB) ile ilgili en çok çalışma yapılan konulardan bir tanesi; elektro iletkenlerin EAB'lerin doğruluğuna olan etkisinin araştırılmasıdır. Modern EAB üreticileri, bu yeni cihazların elektro iletkenlerden olumsuz etkilenmediklerini iddia etseler de bu konu tam olarak kesinlik kazanmamıştır. Bu çalışmada 3 farklı modern EAB (Root ZX mini, Raypex 6, Apex ID) kullanıldı; elektro iletken irrigasyon solüsyonların (%5'lik NaOCl, %0,9'luk Sodyum Klorür (NaCl) çözeltisi ve %17'lik EDTA) varlığında ve kuru kanal koşullarındaki doğruluk oranları değerlendirildi. Çalışmada kullanılmak üzere 64 adet insan maksiller 1. molar dişin meziobukkal kökü seçildi ve rezorbsiyona uğramış, kırık ve açık apeksli kökler çalışmaya dahil edilmedi. Çalışmada 25-35 derece eğime sahip olan kökler kullanıldı ve bu eğim oranlarına sahip olmayan kökler de çalışma dışı bırakıldı. Kök kanal içerikleri boşaltılıp kanallar sırasıyla 25 ve 40 numaralı Reciproc (VDW, Münih, Almanya) döner alet eğeleri ile genişletildikten sonra kökler 40 numara boyterlok kullanılarak lateral yüzeylerinden perfore edildi. Perforasyon noktasına kadar olan gerçek uzunlukların ve elektronik uzunlukların belirlenmesi X4 büyütme (Carl Zeiss Gmbh., Jena, Almanya) altında görsel olarak yapıldı. İstatistiksel analizler sonucunda gerçek uzunluklar ile elektronik ölçümler arasında 0,05 düzeyinde anlamlılık dereceleri bulunan gruplar belirtildi. Kuru kanal koşullarında ve Serum Fizyolojik (SF) ile yıkanan kanallarda, Root ZX cihazı ile yapılan elektronik ölçümlerle gerçek uzunluklar arasında 0,05 düzeyinde anlamlılık dereceleri bulundu. Yine %5'lik NaOCl, %0,9'luk Sodyum Klorür (NaCl) çözeltisi (SF) ve %17'lik EDTA ile yıkanan kanallarda, Raypex 6 ve Apex ID cihazı ile yapılan elektronik ölçümlerle gerçek uzunluklar arasında 0,05 düzeyinde anlamlılık dereceleri bulundu.

Özet (Çeviri)

One of the most studied subjects about electronic apex locators (EAL) from past to present; the effect of electroconductors on the accuracy of EALs. Although modern EAL manufacturers claim that these new devices are not adversely affected by electroconductors, this issue has not been fully clarified. Three different modern EAB (Root ZX mini, Raypex 6, Apex ID) were used in this study. In the presence of electroconductive irrigation solutions (5% NaOCl, 0.9% Sodium Chloride (NaCl) solution and 17% EDTA) and in dry canal conditions, the accuracy of EALs were evaluated. The mesiobuccal root of 64 human maxillary 1st molar teeth free of any resorbtion, cracks and open apices were included. Roots with a curve of radius of 25-35 degrees were used in the study and the roots without these slope ratios were also excluded. Root canal contents were evacuated and canals were prepared with Reciproc (VDW, Munich, Germany) instruments. Determination of actual lengths and electronic measurement to the point of perforation were performed visually under X4 magnification (Carl Zeiss GmbH, Jena, Germany). As a result of the statistical analysis, groups between the actual lengths and the electronic measurementswere defined with significance levels of 0.05. In the dry root channel conditions and Serum Physiological (SP) washed channels, the level of significance was found to be 0.05 between the electronic measurements made with the root ZX device. Also, electronic measurements made with Raypex 6 and Apex ID were found to be significant at the 0.05 level in the channels which was washed 5% NaOCl, 0.9% Sodium Chloride (NaCl), solution (SP) and 17% EDTA.

Benzer Tezler

  1. Farklı intrakanal medikaman uygulamalarının dört farklı apeks bulucunun ölçüm doğruluğuna etkisi

    The effect of different intracanal medications on the accuracy of four different apex finders in measurement

    HAMZA CUDAL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiErciyes Üniversitesi

    Endodonti Ana Bilim Dalı

    DOÇ. DR. TUĞRUL ASLAN

  2. A micro-computed tomographic evaluation of accuracy of different electronic apex locators

    Farklı Apeks bulucuların doğruluğunun mikro bilgisayarlı tomografi kullanılarak değerlendirilmesi

    AYLİN ERGELDİ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiAnkara Üniversitesi

    Endodonti Ana Bilim Dalı

    PROF. DR. FATMA SEMRA SEVİMAY

  3. Farklı apex bulucuların farklı ebatlardaki apikal açıklıklarda doğruluğunun değerlendirilmesi

    In-vitro comparison of the different apex locator at different sizes of apical opening

    MOHAMMED HUSSEIN JEMAA ABOOSHI

    Doktora

    Türkçe

    Türkçe

    2019

    Diş HekimliğiGaziantep Üniversitesi

    Endodonti Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FATMA TUNÇ

    PROF. DR. GÜVEN KAYAOĞLU

  4. Üç değişik apeks bulucunun, farklı çaptaki apikal foramenleri olan dişlerdeki ölçme etkinliğinin incelenmesi: ex vivo bir çalışma

    Examination of the measurement effectiveness of three different apex locators in teeth with different diameters of apical foramen: an ex vivo study

    GÜLER AKTAŞ POLAT

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş Hekimliğiİstanbul Üniversitesi

    Endodonti Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MUZAFFER EMİR DİNÇOL

  5. Üç farklı elektronik apeks bulucu, radyovizyografi ve konik ışınlı bilgisayarlı tomografinin süt dişi kök kanal tedavisinde çalışma boyu belirlenmesinde doğruluğunun değerlendirilmesi

    The accuracy of three different electronic apex locators, radiovisiography and cone-beam computed tomography in determination of the working lenght measurement on primary teeth root canal treatment

    MEVLÜT KAYABAŞI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiSivas Cumhuriyet Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    DOÇ. DR. FATİH ÖZNURHAN