Geri Dön

Farklı kompozitlerin polimerizasyon büzülmesi ve mikrosızıntı değerlerinin in-vitro olarak incelenmesi

In-vitro study of polymerization shrinkage of different composites and microleakage evaluation

  1. Tez No: 549779
  2. Yazar: KÜBRA GÜNER KORKMAZ
  3. Danışmanlar: DOÇ. DR. EMİNE GÜLŞAH GÖKTOLGA AKIN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: kompozit, polimerizasyon büzülmesi, mikrosızıntı, monomer, composite, polymerization shrinkage, microleakage, monomer
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Sivas Cumhuriyet Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 101

Özet

Bu çalışmada düşük polimerizasyon büzülmesi gösteren üç kompozit ve bir geleneksel kompozitin polimerizasyon büzülmesi ve mikrosızıntı skorları değerlendirildi. Çalışmada dört farklı kompozit rezin GC Kalore (GC), Beautifil II LS (Shofu), Charisma Diamond (Kulzer) ve Filtek Z550 (3M ESPE) kullanıldı. Çalışma polimerizasyon büzülmesi testi ve mikrosızıntı testi olmak üzere iki bölümde gerçekleştirildi. Polimerizasyon büzülmesi testi için 80 adet, mikrosızıntı testi için 80 adet olmak üzere toplamda 160 adet örnek hazırlandı. İki aşamalı olarak tasarlanan çalışmanın ilk aşamasında 4 çeşit kompozit rezin ile 20'şer tane örnek hazırlandı ve Acuvol laboratuar cihazıyla (Bisco, Schaumburg; IL, USA) ölçümleri yapıldı. İkinci aşamada ise çekilmiş insan azı dişlerinin bukkal bölgelerine sınıf V kaviteler açılarak dişler rastgele 4 gruba ayrıldı (n=20). Hazırlanan kaviteler dört farklı kompozit rezin (GC Kalore, Beautifil II LS, Charisma Diamond, 3M Filtek Z550) kullanılarak restore edildi. Polimerizasyon işlemi için bir LED ışık cihazı (Valo Cordless, Ultradent, ABD) kullanıldı. Dişler oda sıcaklığında karanlık bir ortamda distile suda 24 saat saklandı. Hazırlanan Sınıf V kompozit restorasyonlar, +5°C ve +55°C sıcaklıkta 30 saniye bekleme süresi ile 500 devir termal döngü uygulandı. Restore edilen dişler % 0.5'lik bazik fuksin çözeltisinde 24 saat süreyle bekletildi. Sonrasında dişler bukko-lingual/palatinal yönde ikiye bölündü ve kesit yüzeyleri stereomikroskopta incelendi. Çalışmamızdan elde edilen veriler SPSS (Ver:22.0) programına yüklenerek verilerin değerlendirilmesinde Varyans Analizi, Tukey Testi, Ki-Kare Testi ve Mann-Whitney U Testi kullanıldı ve yanılma düzeyi p0,05). Çalışmanın sonuçlarından yola çıkarak monomer içeriğinin değiştirilmesiyle kompozitlerin mekanik ve klinik özelliklerinin geliştirilebileceği, bu durumla paralel olarak kompozitlerin bu özelliğinin restorasyonun mikrosızıntısına da etki edebileceğini düşünmekteyiz.

Özet (Çeviri)

This study evaluates three composites showing low polymerization shrinkage, polymerization shrinkage of a conventional composite and microleakage scores. In this study, four composite resin, GC Kalore (GC), Beautifil II LS (Shofu), Charisma Diamond (Kulzer) ve Filtek Z550 (3M ESPE) were used. The study was carried out in two stages as polymerization shrinkage test and microleakage test. A total of 160 samples were prepared as 80 samples for polymerization shrinkage test and 80 samples for microleakage test. In the first phase of the two-stage study 20 samples were prepared using 4 kinds of composite resins and measurements were made with Acuvol laboratory equipment (Bisco, Schaumburg; IL, the USA). In the second phase the teeth were randomly divided into 4 groups by opening class V cavities to the buccal areas of the extracted human molars (n=20). Prepared cavities were restored using four different composite resins (GC Kalore, Beautifil II LS, Charisma Diamond, 3M Filtek Z550). An LED light device (Valo Cordless, Ultradent, ABD) was used for the polymerization process. Teeth were stored in distilled water in a dark environment at room temperature for 24 hours. Prepared Class V composite restorations, , 500 cycles of thermal cycling were applied at 30 ° C and + 55 ° C with a dwell time of 30 seconds. Restored teeth were kept in 0.5% basic fuchsin solution for 24 hours. Afterwards, the teeth were split in a bucco-lingual/palatal direction and cross-sectional surfaces were carefully examined under a stereomicroscope. The data obtained from our study were loaded on SPSS (Ver: 22.0) program and the data were analyzed by using Variance Analysis, Tukey's Test, Chi-Square Test and Mann-Whitney U Test and the error level was taken as p 0,05). Based on the results of the study, we think that the mechanical and clinical properties of composites can be improved by changing the monomer content and this characteristic of composites may affect the microleakage of restoration.

Benzer Tezler

  1. Düşük polimerizasyon büzülmesi gösteren iki posterior kompozit rezinin in-vitro ve klinik olarak uzun dönemli karşılaştırılması

    Showing low shrinkage posterior composite resin two -vitro and clinical long-term comparison

    ESRA YILMAN RAHİMİ ALAGHA

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiEge Üniversitesi

    PROF. DR. FERİT ÖZATA

  2. Işıkla serleşen farklı kompozit resinlerin polimerizasyon büzülmesi ve mikrosızıntısı ile cam-seramik insertlerin polimerizasyon büzülmesi ve mikrosızıntı üzerine etkisinin incelenmesi

    The Examination of the polymerization shrinkage and microleakage of different lightcured composite resins and of the effects of the glass ceramic insertion on polymerization shrinkage and microleakage

    YUSUF ZİYA BAYINDIR

    Doktora

    Türkçe

    Türkçe

    1999

    Diş HekimliğiAtatürk Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF. DR. NİLGÜN SEVEN

  3. Polimerizasyon büzülmesi düşük kompozit rezinlerin mikrosızıntı ve kenar uyumu açısından ın vitro olarak değerlendirilmesi

    In vitro evaluation of microleakage and marginal adaptation of composite resins with low polymerization shrinkage

    ÖZGE KAM

    Doktora

    Türkçe

    Türkçe

    2010

    Diş HekimliğiSüleyman Demirel Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF. DR. R. BANU ERMİŞ

  4. Bis-GMA esaslı dental kompozitlerin fotopolimerizasyonu esnasında oluşan yapısal değişikliklerin matematiksel modellenmesi

    Numerical modeling the structural changes of Bis-GMA-based dental composites during the photopolymerization

    BİLGE SEMA TEKEREK

    Doktora

    Türkçe

    Türkçe

    2015

    BiyomühendislikYıldız Teknik Üniversitesi

    Biyomühendislik Ana Bilim Dalı

    PROF. DR. SEVİL YÜCEL

  5. Farklı rezin kompozitler ile yapıştırılan indirekt restoratif materyallerin in vitro olarak değerlendirilmesi

    In vitro evaluation of indirect restorative materialsbonded with different resin composites

    AYSUN TUĞÇE AKAY

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Diş HekimliğiErciyes Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. SEZER DEMİRBUĞA