Geri Dön

Konik ışınlı bilgisayarlı tomografide kafa pozisyonlandırmasının mandibuladaki kortikal kemik kalınlığı üzerine etkisinin değerlendirilmesi

Evaluation of the effect of head positioning on cortical bone thickness in mandible in cone beam computed tomography

  1. Tez No: 560979
  2. Yazar: BERRİN ÇELİK
  3. Danışmanlar: PROF. DR. CEMİLE ÖZLEM ÜÇOK
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 82

Özet

Görüntüleme tekniklerinde hasta pozisyonlandırması esnasında oluşan hatalar nedeniyle boyutsal ölçümlerde değişiklik meydana gelebilir. Bu durum, klinik pratikte görüntüler üzerinden yapılan ölçümlerde hatalara yol açar. Bu çalışmanın amacı, insan kuru mandibulaları üzerinde yapılan bukkal ve lingual kortikal kemik kalınlığını konik ışınlı bilgisayarlı tomografi (KIBT) görüntüleri üzerinde yapılan ölçümlerle karşılaştırmak, farklı kafa pozisyonlandırmasının KIBT ölçümlerine olan etkisini değerlendirmektir. Ayrıca KIBT ölçümlerinin fiziksel ölçümlere göre oluşan farklılığın diş türü (anterior-premolar-molar) ve çene yönü (sağ-sol çene) etkisini incelemektir. Çalışma için 26 insan kuru mandibulasında, ilgili alanlarda guta perka yardımı ile referans noktalar belirlendi. Ön-arka ve sağ-sol yönde (10o açılama) farklı pozisyonlarda mandibulaların KIBT görüntüleri elde edildi. Mandibula ve radyografik görüntüler üzerinde, bukkal ile lingual kortikal kemiğin kalınlık ortalalamaları hesap edilerek, birbirleri arasındaki ortalama farklar belirlendi. Ölçümler iki gözlemci tarafından yapıldı ve 15 gün sonra ölçümlerin % 15'i tekrarlandı. Elde edilen veriler istatistiksel olarak analiz edildi. Analiz için verilerin dağılımları Shapiro-Wilk testi ve normallik grafikleri ile incelendi. Ölçümler ortalama ± standart sapma (ort±ss) ve ortanca (değişim aralığı: DA) ile özetlendi. Veriler ANOVA testi ile analiz edildi. Ölçümlerin fiziksel ölçümle uyumu ve gözlemci-içi ile gözlemciler arası uyumu sınıf-içi korelasyon katsayı (SKK) ile incelendi. İstatistiksel anlamlılık düzeyi p

Özet (Çeviri)

Changes in dimentional measurements due to malpositioning of patients are possible. This condition leads measurement errors on the images in clinical practice. The aim of this study is to compare the buccal and lingual bone thickness of human dry mandible with the measurements obtained on CBCT images and to evaluate the effects of various head positioning on CBCT. We also aimed to determine the differences between actual physical measurements and CBCT measurements in terms of tooth type (anterior-premolar-molar) and jaw side (right-left). In the present study reference points were indicated by gutta percha in 26 human dry mandibles. The CBCT images of the mandibles were obtained in the anteroposterior and right-left directions (100 angle). The average buccal and lingual cortical bone thickness on dry mandibles and radiologic images were individually measured and the mean difference between actual and radiologic measurements was obtained. The measurements were performed by two observers and 15 days later 15% of the measurements were repeated. Obtained data were statistically analysed. Data distribution was analyzed using Shapiro-Wilk test and normality graphs. The measurements were evaluated by the mean ± standard deviation (mean ± sd) and median (range: R). Data were analyzed by ANOVA test. The consistency of the measurements between two approaches and the intra-observer, inter-observer agreement were examined by intra-class correlation coefficient (ICC). Statistical significance was considered as p < 0.05. It was shown that there was a statistically significant difference between the measurements performed on dry mandibles and CBCT images. Mean differences for buccal and lingual cortical bone thickness were found between 0.005-0.203 mm and 0.004-0.183 mm respectively. CBCT results were higher in the anterior and premolar region and lower in the molar region compared to the values of physical measurements. No statistically significant difference was indicated between right and left jaws in terms of teeth position. High intra-observer and inter-observer compatibility was observed. Head positioning had no effect on the accuracy and reliability of CBCT measurements. It was concluded that there was a statistically significant difference in CBCT measurements compared to physical measurements but this difference corresponds to less than or equal to 0.2 mm and is considered to be in clinically acceptable limits. It is also concluded that CBCT is accurate enough to evaluate buccal and lingual cortical bone thickness. Key Words : CBCT, cortical bone thickness, head positioning, mandible

Benzer Tezler

  1. Temporal kemiğin ve komşuluklarının konik ışınlı bilgisayarlı tomografide farklı fov ve voksel büyüklüklerinde anatomik ve morfolojik retrospektif değerlendirilmesi

    Retrospective evaluation of temporal bone and surrounding structure anatomy and morphology in different fov and voxel sizes with CBCT

    NİHAL YETİMOĞLU ÖZDİL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2016

    Diş HekimliğiAnkara Üniversitesi

    Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı

    PROF. DR. KAAN ORHAN

  2. Panoramik radyografi ve bilgisayarlı tomografide konumlandırmanın dikey boyut üzerine etkilerinin araştırılması: In vitro çalışma

    Investigating the effects of positioning on vertical dimensional measurements in panoramic radiography and computed tomography: In vitro study

    DERYA İÇÖZ

    Doktora

    İngilizce

    İngilizce

    2016

    Diş HekimliğiSelçuk Üniversitesi

    Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı

    PROF. DR. FARUK AKGÜNLÜ

  3. Konik ışınlı bilgisayarlı tomografi kullanılarak olfaktör fossa sınıflandırılması ve ölçümlerinin radyolojik değerlendirilmesi: retrospektif bir çalışma

    Classification and radiological evaluation of olfactory fossa measurements using CONE- BEAM computed tomography: A retrospective study

    MERVE ÖNDER

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Kulak Burun ve BoğazAnkara Üniversitesi

    Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı

    PROF. DR. KAAN ORHAN

  4. Türk toplumunda üç boyutlu sefalometrik normların oluşturulması

    Creation of three dimensional sephalometric norms in Turkish society

    ÖZÜM DAŞDEMİR ÖZKAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiKırıkkale Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. FERABİ ERHAN ÖZDİLER

  5. Fossa olfactoria'nın konik ışınlı bilgisayarlı tomografi görüntüleri üzerinde morfometrik olarak değerlendirilmesi

    Morphometric evaluation of the olfactory fossa on cone BEAM computed tomography images

    HADİCE UÇAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    AnatomiGaziantep Üniversitesi

    Anatomi Ana Bilim Dalı

    DOÇ. DR. İLHAN BAHŞİ