Tam ark implant ölçülerinde dijital ve konvansiyonel yöntemlerin 3 boyutlu netlik karşılaştırılması

Three-dimensional accuracy of conventional vs. digital full-arch implant impressions

  1. Tez No: 565671
  2. Yazar: BERKMAN ALBAYRAK
  3. Danışmanlar: PROF. DR. FUNDA BAYINDIR
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 164

Özet

Tam Ark İmplant Ölçülerinde Dijital ve Konvansiyonel Yöntemlerin Netlik Karşılaştırılması Amaç: İdeal klinik tabloyu yansıtmayan bir tam dişsizlik vakasında, ağız içi tarayıcılarla elde edilecek dijital ölçüler ile konvansiyonel ölçü arasındaki netliğin mesafe ve açı parametrelerinde karşılaştırılması ve bu parametrelerin ölçü yöntemlerinin netlikleri üzerine olan etkilerinin değerlendirilmesi amaçlanmaktadır. Materyal ve Metot: Dişsiz bir alt çene modelinde 47, 44, 43, 41, 33, 34, 35 ve 37 no.lu bölgelere; sırasıyla 40°, 0°, 20°, 0°, 15°, 0°, 0° ve 25° açılanmalar ile toplam 8 adet implant yerleştirilmiştir. İmplantlara scan body yerleştirilerek, bu çalışma modeli Activity 885 Mark 2 Scanner ile taratılmış ve 3 boyutlu referans model elde edilmiştir. Dijital ölçüler Carestream 3500 (D1), Cerec Omnicam (D2) ve 3Shape Trios 3 (D3) olmak üzere 3 farklı ağız içi tarayıcı kullanılarak alınırken; konvansiyonel ölçüler (K1) splintsiz açık kaşık ölçü tekniği ile alınmış ve elde edilen alçı modeller Straumann 7 Series dijital laboratuvar tarayıcısı ile dijitalize edilmiştir (4 ölçü grubu, n:10). Bu ölçü gruplarındaki scan bodyler arası mesafe ve açılar ölçülerek, bir tersine mühendislik programı olan Rapidform'da referans model değerleri ile karşılaştırılmıştır. Normal dağılım gösteren değişkenlerde grup ortalamaları arasındaki farklılık tek yönlü ANOVA testi ile analiz edilirken; normal dağılıma uymayan değişkenlerin analizinde ise nonparametrik Kruskal-Wallis-H testinden yararlanılmıştır. Bulgular: D1 ölçü grubu 123.1 μm ile anlamlı düzeyde netliği en yüksek ölçü grubunu oluştururken; sırasıyla 209.8 μm ve 229.7 μm netlik değerleri olan D3 ile D2 ölçü grupları arasında anlamlı düzeyde bir farklılık bulunamamıştır. K1 ölçü grubu ise 345.3 μm lik netlik değeriyle tüm dijital ölçü gruplarından anlamlı düzeyde yüksek bir boyutsal farklılık göstermiştir (p

Özet (Çeviri)

Three-Dimensional Accuracy of Conventional vs. Digital Full-Arch Implant Impressions Objective: In a case of edentulism that does not reflect the ideal clinical scenario, it is aimed to compare the accuracies of the digital impressions which are obtained with intraoral scanners and the conventional impressions, in terms of distance and angulation; and evaluate the effects of these parameters on the accuracies of these impression techniques. Material & Method: The full-arch implant model to be used in this study; was obtained by placing 8 implants in an edentulous lower jaw to mimic a clinically unfavorable condition. These implants were placed in sites of 47, 44, 43, 41, 33, 34, 35 and 37 with 40°, 0°, 20°, 0°, 0°, 15°, 0° and 25° angulations, respectively. Subsequently, scan-bodies were placed on implants and the model was scanned with Activity 885 Scanner Mark 2 to obtain a 3D reference model. Digital impressions were taken by using 3 different intraoral scanners: Carestream 3500, Cerec Omnicam and 3Shape Trios 3. For conventional impression group, non-splinted open tray impression technique was used and the casts were scanned by Straumann 7 Series lab. scanner (4 different impression groups, n:10). In these impression groups, the distance and angles between the scan bodies were measured and compared with the reference model values in Rapidform, which is a reverse engineering program. The differences between the groups' mean values were analyzed by one-way ANOVA test. Non-parametric Kruskal- Wallis-H test was used in the analysis of variables that did not comply with normal distribution. Results: D1 impression group was found to be significantly the most accurate group with 123.1 μm. There was no significant difference between D3 and D2 impression groups with 209.8 μm and 229.7 μm accuracy values, respectively. K1 group showed a significantly higher deviation with the mean value of 345.3 μm than all digital impression groups (p

Benzer Tezler

  1. Three-dimensional accuracy comparison of digital and conventional impression methods in full-arch implant impression

    Tam ark implant ölçülerinde dijital ve konvansiyonel ölçü yöntemlerinin üç boyutlu doğruluk karşılaştırması

    ILGIN ÖZER

    Doktora

    İngilizce

    İngilizce

    2023

    Diş HekimliğiYeditepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ENDER KAZAZOĞLU

  2. Dijital ve yarı-dijital iş akışlarının tam ark implant üstü ölçüleri üzerindeki doğruluk ve hassasiyetinin karşılaştırılması

    Comparison of trueness and precision of digital and semi-digital workflows on complete-arch implant impressions

    MÜNİR DEMİREL

    Doktora

    Türkçe

    Türkçe

    2022

    Diş HekimliğiBiruni Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SEVİL MERAL ŞAHMALI

    DR. ÖĞR. ÜYESİ MUSTAFA BORGA DÖNMEZ

  3. Tam ark implant ölçülerinde farklı dijital ağız içi tarayıcıların 3boyutlu netlik karşılaştırması

    Three-dimensional accuracy of different digital intraoral scanners comparision in full arch implant impressions

    ÖZCAN AKKAL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiAtatürk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. FUNDA BAYINDIR

  4. İmplant destekli tam ark tek parça üst yapı üretiminde ağıziçi dijital ölçü yönteminin değerlendirilmesi

    Evaluation of intraoral scanning technique in fabrication of implant supported full arch fixed screw retained superstructure

    MERVE VAROL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiHacettepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. KIVANÇ AKÇA

  5. Dijital implant ölçü netliğinin artırılmasına etkili parametrelerin incelenmesi

    Evaluation of the parameters effecting the accuracy of digital implant impressions

    GÖRKEM GÖKSOY

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BİLGE GÖKÇEN RÖHLİG