Three-dimensional accuracy comparison of digital and conventional impression methods in full-arch implant impression
Tam ark implant ölçülerinde dijital ve konvansiyonel ölçü yöntemlerinin üç boyutlu doğruluk karşılaştırması
- Tez No: 790191
- Danışmanlar: PROF. DR. ENDER KAZAZOĞLU
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dijital Diş̧ Hekimliği, Dijital Ölçü̈, İmplant üstü ölçü, Ağız içi Tarayıcı, Hassasiyet, Dental implantasyon, Dental implantlar, Dijital tarama, Diş hekimliği, Protezler ve implantlar, Sayısal tarayıcılar, Üç boyutlu görüntüleme, Digital Dentistry, Digital Impression, Implant Impression, Intraoral Scanner, Accuracy, Dental implantation, Dental implants, Digital scanning, Dentistry, Prostheses and implants, Digital scanners, Three dimensional imaging
- Yıl: 2023
- Dil: İngilizce
- Üniversite: Yeditepe Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Çalışmamızın amacı, implant destekli protetik tedavilerde kullanılacak ağız içi tarayıcılar ile konvansiyonel yöntemin doğruluk ve hassasiyetini değerlendirmektir. Çalışmamızda, açılı ve paralel yerleştirilmiş 6 implantlı tam dişsiz poliüretan alt çene modeli referans model olarak kullanılmıştır. Referans modelden CMM (CMM Contura G2 10/16/06 RDS; Carl Zeiss Industrielle Mess Technik GmbH -Koordinat ölçüm makinesi) yardımıyla dijital bir referans model oluşturuldu. Referans model piyasada bulunan 5 farklı ağız içi tarayıcı (3Shape Trios4, Planmeca EmeraldS, Itero Element 5D,3Disc Heron, Primescan) ile 10'ar kez taranarak dijital veriler oluşturuldu. Referans modellerden ayrıca 10 adet konvansiyonel ölçü alınmış ve ölçüden elde edilen alçı modeller endüstriyel referans tarayıcı (3Shape 3E Lab Scanner, Kopenhag, Danimarka) ile taranarak STL formatında veriler elde edilmiştir. Tüm dijital veriler bir tersine mühendislik programı (Geomagic Control X, Geomagic, ABD) ile sanal ortamda kaydedilmiştir. İstatistiksel analizler IBM SPSS yazılımı sürüm 28 kullanılarak gerçekleştirilmiştir. Çoklu karşılaştırmalar için Bonferroni düzeltmesi kullanılarak ikili farklılıkların anlamlılığını test etmek için Mann-Whitney U testi yapılmıştır. Primescan grubu ve Itero Element5D grubunun medyan sapma değerleri, Emerald S-Planmeca grubu, Heron ios-3disc grubu ve konvansiyonel ölçü grubunun sapma değerlerinden istatistiksel olarak anlamlı derecede düşük bulunmuştur. (P<0,05) Konvansiyonel ölçü grubunun medyan sapma değerleri Heron ios-3disc grubunun sapma değerlerinden istatistiksel olarak anlamlı derecede düşük bulunmuştur. (P<0,05) Bu in vitro çalışmada, dental implantlar için dijital ve geleneksel ölçü alma yaklaşımlarının doğruluğu klinik olarak kabul edilebilir görünmektedir ve bu nedenle tam ark, çoklu implant restorasyonları için uygulanabilir olarak kabul edilebilir.
Özet (Çeviri)
The aim of our study was to evaluate the trueness and precision of intraoral scanners and conventional method to be used in implant supported prosthetic treatments. Complete edentulous polyurethane lower jaw model with 6 implants placed both angled and parallel was used as a reference model. A digital reference model was created with the help of a CMM (Contura G2 10/16/06 RDS; Carl Zeiss Industrielle Mess Technik GmbH Coordinate measuring machine). Reference model was scanned 10 times each with 5 different intraoral scanners (3Shape Trios4, Planmeca EmeraldS, Itero Element 5D,3Disc Heron, Primescan) available in the market and digital data were created. 10 conventional impression (Elite HD, Zhermack Spa, Italy) were also taken from the reference models and the plaster models obtained from the impression were scanned with an industrial reference scanner (3Shape 3E Lab Scanner, Copenhagen, Denmark) and data in STL format were obtained. All digital data were registered in a reverse engineering program (Geomagic Control X, Geomagic, USA). Statistical analyses performed using the IBM SPSS software version 28. The Mann-Whitney U test was performed to test the significance of pairwise differences using Bonferroni correction adjust for multiple comparisons. As a result, the median deviation values of the Primescan group and Itero Element5D group were found to be statistically significantly lower than the deviation values of the Emerald S-Planmeca group, Heron ios-3disc group and conventional impression group. (P<0,05) The median deviation values of the conventional impression group were found to be statistically significantly lower than the deviation values of the Heron ios-3disc group. (P<0,05) In this in vitro study, the accuracy of the digital and conventional impression making approaches for dental implants seems to be clinically acceptable and can therefore be considered applicable for full-arch, multiple implant restorations.
Benzer Tezler
- Dijital ve konvansiyonel iş akışı ile üretilen modellerdeki implant konumlarının doğruluğunun in vitro olarak karşılaştırılması
In vitro comparison of the accuracy of implant locations in models manufactured with digital and conventional workflow
MELİH MERSİN
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiErciyes ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. KEREM KILIÇ
- İmplant destekli sabit bölümlü protezlerde dijital ve konvansiyonel ölçü yöntemlerinin karşılaştırılması
Comparison of digital and conventional impression methods in implant supported fixed partial dentures
İSMAİL KILIÇ
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiSelçuk ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. OĞUZ ERASLAN
- Tam ark implant üstü dijital ölçü doğruluğuna yardımcı yöntemlerin etkisinin İn Vitro olarak incelenmesi
In vitro investigation of the effects of auxiliary methods on the accuracy of full-arch implant digital impressions
HAFİZE DİZEK
Diş Hekimliği Uzmanlık
Türkçe
2024
Diş Hekimliğiİzmir Katip Çelebi ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. SÜLEYMAN AGÜLOĞLU
- Direkt ve indirekt dijitalizasyon ile üretilen 5 üyeli monolitik zirkonya restorasyonların marjinal ve internal uyumunun 3 boyutlu karşılaştırması: İn vitro çalışma
Comparison of marginal and internal fit of 5-unit monolithic zirconia fixed dental prostheses made with direct and indirect digitalization: An in vitro study
İREM GÖKÇE ULUÇ
Diş Hekimliği Uzmanlık
Türkçe
2020
Diş HekimliğiHacettepe ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. MUSTAFA BARIŞ GÜNCÜ
- Üç boyutlu baskı tekniğiyle üretilen dental modellerin doğruluğunun değerlendirilmesi
Evaluation of the accuracy of dental models manufactured with three-dimentional printing technique
HİLİN TAŞ
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş Hekimliğiİnönü ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DR. ÖĞR. ÜYESİ FATİH DEMİRCİ
DR. ÖĞR. ÜYESİ MESUT TUZLALI