Radyoterapide kullanılan lineer hızlandırıcıların fiziksel ve dozimetrik paratmetrelerinin karşılaştırılması

The comparison of physical and dosimetric parameters of linear accelerators using in radiotherapy

  1. Tez No: 578640
  2. Yazar: ALPER OĞUZ
  3. Danışmanlar: DOÇ. DR. AYSEL ERSOY YILMAZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyomühendislik, Bioengineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi-Cerrahpaşa
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Biyomedikal Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Biyomedikal Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: 74

Özet

Bu çalışmada, kalp hastalıklarından sonraki en çok ölüme sebebiyet veren kanser hastalığının tedavi yöntemlerinden biri olan radyoterapi tekniğinin uygulanmasını sağlayan ışın tedavisi cihazları incelenmiştir. Yapılan literatür araştırması ile, sistemlerin sınıflandırılması, yapıları, tarihsel olarak gelişimleri incelenmiştir. Daha sonra ışın tedavi cihazlarının günümüzde en çok kullanım alanına sahip tipi olan lineer hızlandırıcı cihazlarının üç ana üretici firmasına ait İstanbul Üniversitesi Çapa Tıp Fakültesi Onkoloji Enstitüsü ile İstanbul Üniversitesi Cerrahpaşa Tıp Fakültesi Radyasyon Onkolojisi Anabilim Dalında yer alan lineer hızlandırıcı cihazların mekanik ve dozimetrik olarak karşılaştırılmaları yapılmıştır. Karşılaştırma yapılırken, sistemlerin çalışabilirlik onayının alınması esnasında kullanılan ve uluslararası ilgili komitelerce belirlenmiş, ülkemiz sınırları içinde ise Fizik Mühendisleri Odası tarafından yayımlanmış olan test setleri kullanılmıştır. Üç farklı üreticiye ait sistemler üzerinde karşılaştırmalar yapılırken testler mekanik ve dozimetrik olarak iki ana başlık altında incelenmiş ve karşılaştırılmaları yapılmıştır. Mekanik testler yapılırken, milimetrik kağıtlar, şerit metreler, hassas su terazileri vb. ekipmanlar kullanılmıştır. Dozimetrik testler yapılırken ise, insan vücudu yapısını modelleyen su fantomu sistemi, radyasyon dozunu ölçmek için kullanılan iyon odaları ve elektrometre sistemleri, x-ray filmleri gibi özel ölçüm ve değerlendirme aletleri kullanılmıştır. Sistemlerin mekanik olarak birbirleri ile çok büyük farklar barındırmaması sebebi ile mekanik karşılaştırma birbirleri arasında yapılabilmiştir. Dozimetrik sistem testlerinde ise, yapılan literatür araştırmalarından elde edilen verilere göre farklı ışın üretme sistemleri kullandıkları tespit edilmiştir. Bu nedenle birbirleri arasında karşılaştırma yapılmayıp katalog değerlerinin uygulama bakımından karşılaştırmaları yapılmıştır. Gerçekleştirilen ölçümlerin karşılaştırılması ile elde edilen sonuçlara göre, tüm ölçüm sonuçları ülkemiz sınırları içinde lineer hızlandırıcı cihazlarının klinik olarak hasta tedavisinde kullanılabilmesi için gerekli izinleri veren Fizik Mühendisleri Odası test standartlarını karşıladığı görülmüştür.

Özet (Çeviri)

In this study, radiation therapy devices that provide the application of radiotherapy technique, which is one of the treatment methods of cancer disease, which causes the most death after heart diseases, were investigated. With the literature research, the classification, structure and historical development of the systems were examined. Then, linear accelerator devices which are the most widely used type of radiation therapy devices are compared mechanically and dosimetrically with linear accelerator devices in Oncology Institute of Istanbul University Çapa Medical Faculty and Radiation Oncology Department of Istanbul University Cerrahpaşa Medical Faculty. In the comparison, the test kits specified by international committees and approved by national authority, Chamber of Physics Engineers, were used. While comparisons were made on systems belonging to three different manufacturers, tests were examined mechanically and dosimetric under two main headings and comparisons were made. While performing mechanical tests, some equipments such as milimetric papers, tape meters, balance scales etc. were used. While dosimetric tests were carried out, special measurement and evaluation instruments such as water phantom system simulating human body structure, ion chambers and electrometer systems used to measure radiation dose, x-ray films were used. Because the systems do not have very big differences with each other mechanically, mechanical comparison can be made between each other. In dosimetric system tests, it was determined that they use different beam generation systems according to the data obtained from the literature researches. Therefore, no comparison was made between each other and catalog values were compared in terms of application. According to the results obtained by comparing the measurements, it was seen that all the measurement results meet the standards of Chamber of Physical Engineers, which give the necessary permissions for the use of linear accelerator devices in the clinical treatment of patients in our country.

Benzer Tezler

  1. Lineer hızlandırıcılarda fiziksel ve sanal kama filtrelerin karşılaştırılması ve dozimetrik değerlendirilmesi

    The comparison and dosimetric assessment of physical and virtual wedge filters of linear accelerators

    AYCAN ŞENGÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    Fizik ve Fizik MühendisliğiUludağ Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. GÖKAY KAYNAK

  2. Radyoterapide kullanılan lineer hızlandırıcıların bilgisayarda modellenerek çıkış spektrumlarının incelenmesi

    Investigation of output spectrums by computer modeling of linear accelerators used in radiotherapy

    GÖRKEM AYDOĞDU

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    Fizik ve Fizik MühendisliğiCelal Bayar Üniversitesi

    Fizik Bölümü

    DOÇ. DR. GÜLTEKİN YEĞİN

  3. Medikal lineer hızlandırıcılarda absorbe doz ölçüm yöntemlerinin protokollere göre karşılaştırılması

    Comparison of medical linear accelerators according to the protocols of absorbed dose measurement methods

    MUSTAFA POLAT

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    OnkolojiAfyon Kocatepe Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. RIDVAN ÜNAL

  4. Farklı iki lineer hızlandırıcı cihazının elektron dozimetrik parametrelerinin karşılaştırılması

    Comparing dosimetric parameters of electron energies of two different linear accelerator

    HİKMETTİN DEMİR

    Yüksek Lisans

    Türkçe

    Türkçe

    2008

    Fizik ve Fizik MühendisliğiGazi Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. GÜNEŞ TANIR

  5. Radyoterapide kullanılan parçacık hızlandırıcıları

    Particle accelerators used in radiotherapy

    AYŞE AYDIN

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Fizik ve Fizik MühendisliğiTokat Gaziosmanpaşa Üniversitesi

    Yüksek Enerji ve Plazma Fiziği Ana Bilim Dalı

    DOÇ. DR. MUSTAFA NUMAN BAKIRCI