Termik santrallerin FGD ünitelerinde kükürt dioksit arıtma veriminin belirlenmesi

Determination of sulfur dioxide removal efficiency in FGD units of thermal power plants

  1. Tez No: 581006
  2. Yazar: SEMİH ERYILMAZ
  3. Danışmanlar: PROF. DR. AYTEN GENÇ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Zonguldak Bülent Ecevit Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 97

Özet

Bu çalışmada termik santrallerdeki baca gazı kükürt arıtma ünitelerinde (FGD) kireçtaşı çözeltisi ile baca gazından kükürt dioksitin uzaklaştırılmasında verimin belirlenmesi hedeflenmiştir. Öncelikle literatürdeki kükürt dioksit giderim verimi modelleme çalışmaları detaylı olarak araştırılmış ve iki film teorisi ile kütle transfer yasalarına bağlı bir model seçilmiştir. Seçilen kükürt dioksit giderim modelinde verimi etkileyen parametreler toplam gaz kütle transfer katsayısı, sıvı-gaz arayüzey alanı, baca gazı debisi, çözelti debisi, absorpsiyon kolonu hacmi ve sıcaklıktır. Ayrıca kükürt dioksit giderim modelinin geçerliliği Zonguldak ilinde bulunan termik santraldeki dört FGD ünitesinin bir yıllık işletme verileri analiz edilerek değerlendirilmiştir. FGD ünitelerinde kütle transfer katsayısı fiziksel ortam şartlarının yanında temel olarak sıvı-gaz temas alanı ve akış dinamiğine bağlıdır. Kütle transfer iyileştirme faktörü 5 olduğunda kükürt dioksit işletme giderim verimlerine en yakın model tahminleri elde edilmiştir. Bu sonuç, kükürt dioksit gazının kireçtaşı çözeltisine transferinde en önemli adımın difüzyon olmasına rağmen, çözeltide oluşan reaksiyon hızlarının da etkili olduğunu göstermektedir. Çözelti debisinin (L) baca gazı debisine (G) oranı arttığında, kükürt dioksit giderim modelinden elde edilen verim tahminlerinde artış elde edilmiştir. Benzer durum FGD ünitelerinden elde edilen işletme giderim verimleri için de geçerlidir. L/G oranına bağlı olarak elde edilen model ve işletme giderim verimleri arasındaki en yüksek fark %4,1'dir. Ayrıca kükürt dioksit giderim modelinden Tesis I ve Tesis II'deki FGD ünitelerinde en uygun L/G çalışma oranları sırasıyla 15,5 ve 13,3 olarak elde edilmiştir. Bu oranların FGD ünitelerinde işletmede uygulanan L/G oranları ile eşleştiği belirlenmiştir. Bu sonuçlar kükürt dioksit giderim modelinin çalışılan dört FGD ünitesinden elde edilen işletme verileri ile uyumlu olduğunu göstermektedir. Damlacık çapı sıvı-gaz arasındaki arayüzey alanını belirleyen önemli bir parametredir. Damlacık çapındaki artış sıvı-gaz temas alanında azalışa neden olacağından kükürt dioksit giderim veriminde azalma tahmin edilmektedir. Kükürt dioksit giderim modelinden elde edilen sonuçlar damlacık çapı 1600 µm'den 2000 µm'ye artırıldığında giderim veriminde yaklaşık %3 oranında düşüş olduğunu göstermiştir. FGD ünitelerinden elde edilen işletme verileri incelendiğinde, absorpsiyon kolonundaki sıcaklık ve pH değerleri arttığında kükürt dioksit giderim veriminin arttığı gözlenmiştir. Ancak geliştirilen kükürt dioksit giderim modeli FGD ünitesinde sabit sıcaklık ve pH için geçerli olduğundan bu parametrelerdeki değişimlerin giderim verimine olumlu etkisi belirlenememiştir.

Özet (Çeviri)

In this study, the efficiency of desulphurisation from flue gas was aimed to be determined with limestone solution in flue gas desulphurisation unit (FGD) at thermal power plants. First, the modeling studies on sulfur dioxide removal efficiency in the literature have been examined in detail and a model based on two film theory and mass transfer laws have been chosen. The total gas mass transfer coefficient, liquid-gas interface area, flue gas flow rate, solution flow rate, absorber volume and temperature are the parameters, which affect removal efficiency in the sulfur dioxide removal model. In addition, the validity of the sulfur dioxide removal model was evaluated by analyzing the operating data of the four FGD units of Plant I and Plant II thermal power plants located at Zonguldak. In FGD units, the mass transfer coefficient is mainly dependent on the fluid-gas contact area and flow dynamics, as well as the physical environment conditions. When the mass transfer improvement factor is 5, the closest model estimations were obtained to the operational removal efficiencies. This result shows that even though diffusion is the most important step in the transfer of sulfur dioxide gas to the limestone solution, the reaction rates formed in the solution are also effective. When the ratio of solution flow rate (L) to flue gas flow rate (G) is increased, the removal efficiency estimates obtained from the sulfur dioxide removal model also increase. The same conclusion was also observed in the analysis of the operational removal efficiencies obtained from FGD units. Depending on the L/G ratio, the highest difference between the model and operational removal efficiencies is 4.1%. In addition, the optimum L/G working ratios were obtained from the sulfur dioxide removal model as 15.5 and 13.3, respectively, in the FGD units in Plant I and Plant II. It was observed that these L/G ratios were applied in FGD units. These results show that the sulfur dioxide removal model is consistent with the operating data obtained from the four FGD units studied. The droplet diameter is an important parameter that determines the interface area between liquid and gas. Since the increase in droplet diameter will cause a decrease in the liquid-gas contact area, a decrease in sulfur dioxide removal efficiency is predicted. The sulfur dioxide removal model results shows approximately 3% decreases in removal efficiency as the droplet diameter increased from 1600 to 2000 µm. The analysis of the operating data of FGD units shows that increases in temperature and pH cause increases in sulfur dioxide removal efficiency. However, since the developed sulfur dioxide removal model is valid for constant temperature and pH in FGD unit, the effect of variations in these parameters on removal efficiency could not be determined.

Benzer Tezler

  1. Farklı endüstriyel atıklardan sentezlenen hidroksiapatitin adsorban olarak kullanılmasıyla atık sulardan ağır metal geri kazanımı

    Heavy metal recovery from waste waters using hydroxyapatite which syhnthesized from different industrial wastes as an adsorbent

    SILA KIZILTAŞ DEMİR

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Kimya MühendisliğiYıldız Teknik Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. NURCAN TUĞRUL

  2. Termik santral atığı yapay alçı-uçucu kül-taban külü esaslı yapı malzemesi geliştirilmesi

    Development of a power plant by-products (FGD gypsum-fly ASH bottom ASH) based construction material

    HALİT YAZICI

    Doktora

    Türkçe

    Türkçe

    2004

    İnşaat MühendisliğiDokuz Eylül Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF.DR. BÜLENT BARADAN

  3. An Experimental investigation on fly ash-Fgd gypsum-lime based bricks

    Uçucu kül-desülfürizasyon alçısı-kireç esaslı tuğlalar hakkında deneysel bir çalışma

    ÖMER ARIÖZ

    Yüksek Lisans

    İngilizce

    İngilizce

    1997

    İnşaat MühendisliğiOrta Doğu Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MUSTAFA TOKYAY

  4. Termik santral bacagazı arıtma tesisi kaynaklı koagulasyon çamurunda florür giderimi

    Reducing of leachable fluoride in coagulation sludge arise from flue gas desulfurization unit of a coal fired power plant

    CEREN DAVUTLUOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2008

    KimyaÇukurova Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. HUNAY EVLİYA

  5. Termik santrallerin zeytin ağaçlarına etkilerinin belirlenmesi

    Thermal power plants, determination of the effects of olive trees

    ÖZGÜR DURSUN

    Doktora

    Türkçe

    Türkçe

    2022

    ZiraatEge Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

    PROF. DR. FATİH ŞEN