Geri Dön

Farklı ışık kaynakları ile aktive edilen beyazlatma ajanının klinik etkinliğinin değerlendirilmesi

Effect of different light sources on the clinical efficacy of light activated bleaching treatments

  1. Tez No: 609533
  2. Yazar: AYBÜKE USLU
  3. Danışmanlar: PROF. DR. AYŞE RÜYA YAZICI
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 147

Özet

Uslu, A. Farklı Işık Kaynakları ile Aktive Edilen Beyazlatma Ajanının Klinik Etkinliğinin Değerlendirilmesi. Hacettepe Üniversitesi, Diş Hekimliği Fakültesi, Restoratif Diş Tedavisi Anabilim Dalı, Uzmanlık Tezi, Ankara, 2019. Bu randomize klinik çalışmanın amacı, %35 hidrojen peroksit içeren beyazlatma ajanını Diyot lazer veya LED ışık kaynağı ile aktive ederek oluşan renk değişimini, diş hassasiyetini, diş yüzeyinde oluşan sıcaklık değişimini ve dişeti irritasyonunu bölünmüş çene modelinde 9 aylık takipte incelemektir. Çalışmaya çürüksüz ve restorasyon bulunmayan anterior dişlere sahip 35 katılımcı dahil edilmiştir. Bölünmüş çene modelinde %35 lik HP içeren (Whiteness HP, FGM) beyazlatma ajanı kullanılarak, sağ/sol alt-üst çene arklarının bir tarafı Diyot lazer (Epic X, Biolase) ile diğer tarafı ise LED (Radii Plus, SDI) ışık kaynağı ile aktive edilmiştir. Tüm beyazlatma işlemi süresinde kanin dişlerin bukkal yüzeyinden sıcaklık ölçer (DT-3891G K tipi/ J tipi Termometre datalogger, CEM Instruments) cihazı ile meydana gelen sıcaklık değişimi kaydedilmiştir. Diş hassasiyeti VAS (Görsel Analog Skala) ile beyazlatma işlemi öncesinde, sırasında, sonrasında, 48 saat, 1 hafta, 1, 6 ve 9 ay zaman dilimlerinde değerlendirilmiştir. Renk değişimi için subjektif (Vita Klasik Renk Skalası ve Vita 3D Master Beyazlatma Skalası) ve objektif (Vita Easy Shade spektrofotometre) renk değerlendirme yöntemleri kullanılmıştır. Beyazlatma işlemi öncesinde, sonrasında, 48 saat, 1 hafta, 1, 6 ve 9 ay zaman dilimlerinde renk ve dişeti irritasyonu değerlendirmeleri yapılmıştır. Renk değişimi ΔE ve ΔSGU verileri kullanılarak tekrarlı ölçümlerde varyans analizi, çoklu karşılaştırmalarda ise Bonferroni testi ile; sıcaklık değişimi bağımlı gruplarda t-testi ile; diş hassasiyeti Friedman testi kullanılarak istatistiksel analiz yapılmıştır. Her bir zaman diliminde iki ışık kaynağı (Diyot lazer/LED) karşılaştırılırken Wilcoxon testi kullanılmıştır (p0,05). Objektif renk değerlendirilmesinde, 6 aylık kontroller haricinde tüm kontrollerde ortalama ΔE değerleri açısından Diyot lazer ve LED ışık kaynakları arasında fark görülmemiştir (p>0,05). Altı aylık spektrofotometrik değerlendirmede Diyot lazer ile istatistiksel olarak anlamlı daha yüksek ΔE değerleri elde edilmiştir (p0,05). Bu in vivo çalışmanın sınırlamaları dahilinde, Diyot lazer ve LED ışık kaynakları arasında renk değişimi, diş hassasiyeti ve dişeti irritasyonu açısından fark görülmemiştir (p>0,05). Diyot lazer ile diş yüzeyinde oluşan sıcaklık farkı ve maksimum sıcaklık değerleri daha yüksek gözlenirken, ortalama sıcaklık LED ışık kaynağı ile daha yüksek bulunmuştur (p

Özet (Çeviri)

Uslu, A. Effect of Different Light Sources on the Clinical Efficacy of Light Activated Bleaching Treatments. Hacettepe University, Faculty of Dentistry, Department of Restorative Dentistry, Specialization Thesis, Ankara, 2019. The aim of this split-mouth, randomized clinical study was to evaluate the effect of LED or Diode laser activated bleaching applications on color change, tooth sensitivity, gingival irritation and temperature variation with 35% hydrogen peroxide bleaching gel after 9 months. Thirty-five patients with anterior teeth without caries and no restoration were included in this study. In a split-mouth design, a bleaching agent containing 35% HP (Whiteness HP, FGM) was used, one side of each jaw was activated by a diode laser (Epic X, Biolase) and the other side was activated by an LED (Radii Plus, SDI) light source. During the bleaching treatments, the temperature variations were recorded using a thermocouple (DT-3891G K type Thermometer datalogger, CEM Instruments) from the buccal surface of canine teeth. Tooth sensitivity was assessed by Visual Analogue Scale (VAS) before the treatment and during, immediately, 48 hours, 1 week, 1, 6 and 9 months after. Color change was evaluated by subjective (Vita Classic and Vita 3D Master Bleachguide) and objective methods (Vita Easy Shade, spectrophotometer) before the treatment and immediately, 48 hours, 1 week, 1, 6 and 9 months after. Color change (ΔE and ΔSGU) was performed by analysis of variance in repeated measurements. Multiple comparisons were evaluated by Bonferroni test. Temperature variation was evaluated by t-test in dependent groups. Tooth sensitivity was analyzed using Friedman test. Wilcoxon test was used to compare two light sources (Diode Laser/ LED) in each time period (p< 0.05). No difference was found between Diode laser and LED light sources in terms of ΔSGU values in subjective color evaluation (p> 0.05). In the objective color evaluation, no difference was found between Diode laser and LED light sources in terms of mean ΔE values in all time periods, except for 6-month recall (p> 0.05). In the 6-month spectrophotometric evaluation, significantly higher ΔE values were obtained with Diode laser (p 0.05). Within the limitations of this in vivo study, there was no difference between the Diode laser and LED light sources for activating the current bleaching agent in terms of color change, tooth sensitivity, and gingival irritation (p> 0.05). While the temperature difference and maximum temperature values on the tooth surface were higher with Diode laser, the mean temperature was higher with LED light source (p

Benzer Tezler

  1. Farklı ışık cihazları ve farklı uygulama teknikleri ile polimerize edilen bir posterior kompozitin mikrosertlik, polimerizasyon büzülmesi ve polimerizasyon esnasinda açığa çıkan ısı açısından değerlendirilmesi

    The evaluation of microhardness, polymerization shrinkage and the heat released during polymerization of a posterior composite polymerized with different techniques and different light devices

    CİHAN ÖZ

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiDicle Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    DOÇ. DR. BUKET AYNA

  2. LED and visible light-induced metal free ATRP using reducible dyes in the presence of amines

    İndirgenebilir boyar madde/amin sistemi ile LED ve görünür bölge ışığıyla başlatılmış metal içeriksiz ATRP

    CEREN KÜTAHYA

    Yüksek Lisans

    İngilizce

    İngilizce

    2016

    Kimyaİstanbul Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. YUSUF YAĞCI

  3. Visible light-induced atom transfer radical polymerization

    Görünür bölge atom transfer radikal polimerizasyonu

    MUSTAFA ÇİFTÇİ

    Yüksek Lisans

    İngilizce

    İngilizce

    2012

    Kimyaİstanbul Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. YUSUF YAĞCI

  4. The role of oxidative stress factors in the pathophysiology of Ocular Rosacea, analysis of tears and other materials

    Oküler Rosacea patofizyolojisinde oksidatif stres faktörlerinin rolü, gözyaşı ve diğer materyallerin analizi

    NİLÜFER YEŞİLIRMAK

    Doktora

    İngilizce

    İngilizce

    2023

    BiyokimyaGazi Üniversitesi

    Tıbbi Biyokimya Ana Bilim Dalı

    PROF. DR. NESLİHAN BUKAN

    PROF. DR. JEAN-LOUIS BOURGES

  5. Refugee entrepreneurship and the limits of inclusion: A study of Syrian refugee entrepreneurs' embeddedness in Turkey

    Mülteci girişimciler ve içermenin sınırları: Türkiye'deki Suriyeli girişimcilerin gömülülükleri üzerine bir çalışma

    UĞUR YETKİN

    Doktora

    İngilizce

    İngilizce

    2022

    İşletmeİstanbul Teknik Üniversitesi

    İşletme Ana Bilim Dalı

    DOÇ. DR. DENİZ TUNÇALP