Dijital radyografideki göğüs incelemelerinde farklı tüp voltajının tüm vücut dozu ve görüntü kalitesine etkisinin araştırılması

Invastigation of different tube voltage effect on effective dose and image quality for chest radiography with a digital radiography system

  1. Tez No: 618692
  2. Yazar: DUYGU YAVUZ
  3. Danışmanlar: DOÇ. DR. EREN ŞAHİNER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: 90

Özet

Görüntü kalitesi tanısal radyolojide önemli bir rol oynamaktadır. Dijital görüntülemenin, görüntüleri sayısal olarak elde etme, işleme ve saklama gibi avantajları vardır. Dijital dedektörlerin geniş dinamik aralığa sahip olması, daha iyi kalitede görüntülerin elde edilmesine olanak sağlarken, hasta dozunda artışa sebep olabilmektedir. Bu nedenle görüntü kalitesi optimizasyonunun, doz ölçümleri ile birlikte yürütülmesi gerekmektedir. ALARA (As Low As Reasonably Achievable) prensibine göre ışınlama, gerekli tanısal bilgileri elde etmek için ayarlanmalıdır ve hastaya verilen radyasyon dozu mümkün olduğu kadar düşük seviyede tutulmalıdır. Bu durum, hasta dozu ve görüntü kalitesi arasında optimizasyon sağlanması gerekliliğini ortaya koymaktadır. Bu tez çalışmasında, göğüs radyografisinde RANDO fantom üzerinde TLD-100H (LiF:Mg,Cu,P) ve TLD-100 (LiF:Mg,Ti) dozimetreler kullanılarak sabit dedektör dozunda ve farklı demet kalitelerinde cilt giriş dozu ve etkin doz hesaplanmıştır. Ayrıca, farklı demet kalitelerinde, hem sabit dedektör dozunda hem de farklı dedektör dozlarında görüntüler alınarak, görüntü kalitesi VI (Vissible Index) ile sayısal olarak değerlendirilmiştir. Deneysel olarak elde edilen cilt giriş dozu sonuçları, TLD-100H'ın, TLD-100'e göre tanısal radyoloji enerji aralığında daha hassas olduğunu göstermiştir Elde edilen sonuçlar PCXMC Monte Carlo tabanlı simülasyon programı ve Eff.Dose programı ile hesaplanarak karşılaştırılmıştır. Doz ölçümlerinde deneysel olarak elde edilen sonuçların referans sınır değerler içerisinde olduğu ve deneysel sonuçlar ile yazılım programlarından elde edilen sonuçların birbiri ile uyumlu olduğu görülmüştür. Buna bağlı olarak hesaplanan etkin doz değerlerinin, farklı demet kaliteleriyle değişimi beklenildiği gibi çıkmıştır. Görüntü kalitesi değerlendirmesinde, sabit bir etkin doz değerinde, azalan tüp voltajı ile görüntü kontrastının arttığı görülmüştür. Ayrıca değişen dozla birlikte VI değeri artış göstermiştir.

Özet (Çeviri)

Image quality have a important role in digital detectors. Dijital imaging has the avantages of digitally acquiring, processing and storing images. Dijital detectors have a wide dynamic range so better quality images can be obtained but this can lead to an increase in patient dose. Therefore, image quality optimization should be carry out in with dose measurements. According to the ALARA (As Low As Reasonably Achievable) principle, irradiation should be adjusted to obtain the necessary diagnostic information and the radiation dose given to the patient should be kept as low as possible. This suggests an ideal optimization between patient dose and image quality. In this thesis, entrance skin dose and effective dose were calculated using TLD-100H (LiF:Mg,Cu,P) and TLD-100 (LiF:Mg,Ti) dosimeters at fixed detector dose and different beam qualities on RANDO phantom. Moreover, image quality evaluations were calculated using the visibility index. According to experimentally obtained entrance skin dose results, TLD-100H is more sensitive than TLD-100 diagnostic radiology in the energy range. The results were compared with PCXMC Monte Carlo simmulation software and Eff.Dose programme. The results obtained are within reference dose limits and experimental results are compatible with the results obtained software programmes. The variation of the calculated effective dose values with different tube voltages is as expected. There is no noticeable difference in the effective dose values for varying tube voltages. In addition, image quality evaluations were made by taking images in different beam quality, both at fixed detector dose and at different detector doses VI value increased with increasing receptor dose and increased image contrast with decreasing tube voltage

Benzer Tezler

  1. Şüpheli pnömokonyoz olgularında, PA akciğer grafilerinin, ekran ve film değerlendirmeleri karşılaştırması

    Comparison of hard copy and soft copy evaluation of chest Z rays in suspicious pneumoconiotic findings

    ENDER EVCİK

    Doktora

    Türkçe

    Türkçe

    2017

    Halk SağlığıAnkara Üniversitesi

    Halk Sağlığı Ana Bilim Dalı

    PROF. DR. BİRGÜL PİYAL

  2. The clinical performance evaluation of tablet, large screen TV and medical grad monitors for teleradiology and general use purposes

    Tablet,büyük ekran TV ve tıbbi grad monitörün teleradiology ve genel kullanım amaçlı klinik performans değerlendirmesi

    ROYA NOURI RIKABAD

    Yüksek Lisans

    İngilizce

    İngilizce

    2015

    BiyoistatistikBoğaziçi Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DOÇ. ALBERT GÜVENİŞ

  3. Assessment of hard tıssue densıty around dental ımplants usıng conventıonal radıographs

    Dental implantlar çevresindeki sert doku densitesinin konvensiyonel radyograflar ile incelenmesi

    WAEL ALSHAIBANI

    Doktora

    İngilizce

    İngilizce

    2010

    Diş HekimliğiGazi Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. DR. NUR MOLLAOĞLU

  4. Doğalgaz ve petrol boru hatlarındaki kaynaklı bağlantıların radyografik kontrollerinde dijital radyografi ile klasik yöntemlerin kıyaslanması

    Comparison of digital radiography and classic methods for radiographic control of welded connections in natural gas and oil pipelines

    İZZET CİHAN AKAT

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Makine MühendisliğiBolu Abant İzzet Baysal Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. GÜRCAN YILDIRIM

  5. Dijital radyografide görüntü kalitesine ve hasta dozuna bağlı olarak optimum grid seçiminin araştırılması

    Investigation of optimum grid selection based on image quality and patient dose digital radiography

    DİLRUBA BABÜROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. TURAN OLĞAR