Sağlıklı bireylerde servikal propriosepsiyon ölçümünde, AOS proppoint® cihazının geçerlilik ve güvenilirliğinin araştırılması

For measuring cervical proprioception in healthy individualsinvestigation of the validity and reliability of AOS proppoint® device

  1. Tez No: 638436
  2. Yazar: AYGÜL KÖSEOĞLU
  3. Danışmanlar: DR. ÖĞR. ÜYESİ DİLBER KARAGÖZOĞLU, DOÇ. DR. EBRU KAYA MUTLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizyoterapi ve Rehabilitasyon, Physiotherapy and Rehabilitation
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Bahçeşehir Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizyoterapi ve Rehabilitasyon Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 102

Özet

Çalışmamızın amacı tasarlamış olduğumuz lazer aparatlı AOS PropPoint® cihazının, servikal eklem pozisyon hissi (E.P.H.) değerlendirilmesinde geçerli ve güvenilir bir yöntem olup olmadığının araştırılması ve servikal propriosepsiyon değerlendirilmesin standardize edilmiş bir lazerli ekipmanın literatüre ve kliniklere kazandırılmasıdır. Çalışmaya 86 sağlıklı (57 kadın, 29 erkek) katılımcı dahil edildi. AOS PropPoint® cihazının güvenilirliği için test-tekrar-test (intra-rater güvenilirlik) yöntemi ve değerlendiriciler arası güvenilirlik (inter-rater güvenilirlik) yöntemi kullanıldı. Cihazın güvenilirlik analizi için sınıf-içi korelasyon katsayısı (Intra-class Correlation Coefficient (ICC)) kullanıldı. Testin hassasiyeti standart ölçüm hatası (Standard Error of Measurement (SEM)) ve algılanabilir minimum değişikliği (Minimal Detectable Change (MDC)) ile ölçüldü. Cihazın geçerliliğinin araştırılmasında ise servikal propriosepsiyon değerlendirilmesinde altın standart olarak kabul edilen Cervical Range of Motion (CROM) cihazının ölçüm sonuçları ile arasındaki korelasyon incelendi. Gönüllü katılımcıların servikal eklem propriosepsiyonları, Cervical Range of Motion (CROM) cihazı ve AOS PropPoint® cihazı kullanılarak eklem pozisyon hissi hatası testi (E.P.H.H.T.) ile değerlendirildi. AOS PropPoint® cihazı ile yapılan ölçümler frontal ve horizontal düzlem platformlarında iki ayrı hedef tahtası ile değerlendirildi. Cihazın horizontal platformdaki servikal E.P.H. ölçümünün orta derecede güvenilir ve yüksek derecede geçerli bir yöntem olduğu bulunurken (r=0,82-0,84; ICC=0,67-0,73); frontal düzlemdeki ölçümlerinin orta derecede güvenilir ve düşük derecede geçerli bir yöntem olduğu bulundu (ICC= 0,59-0,50; r=0,22-0,21). Cihazın değerlendiriciler arasındaki güvenilirliğinin ise iyi derecede olduğu bulundu (ICC=0,89-0,80). Elde edilen sonuçlara göre; AOS PropPoint® cihazının servikal eklem propriosepsiyon ölçümlerinde geçerli ve güvenilir bir yöntem olduğu bulundu.

Özet (Çeviri)

The aim of our study is to investigate the AOS PropPoint® device with laser apparatus we designed is a valid and reliable method for evaluating cervical joint position sensation (C.J.S.) and to gain a standardized laser equipment to the literature and clinics by evaluating cervical proprioception. 86 healthy (57 women, 29 men) participants were included in the study. For the reliability of the AOS PropPoint® device, retest (intra-rater reliability) method and inter-rater reliability method were used. In-class correlation coefficient (ICC) was used for reliability analysis of the device. The sensitivity of the test was measured with the standard error of measurement (SEM) and the minimum detectable change (MDC). In the investigation of the validity of the device, the correlation between the results of the Cervical Range of Motion (CROM) device, which is accepted as the gold standard in the evaluation of cervical proprioception, was examined. The cervical joint proprioceptions of the volunteer participants were evaluated using the Cervical Range of Motion (CROM) device and the AOS PropPoint® device using the cervical joint position error test (J.P.E.T.). Measurements made with AOS PropPoint® device were evaluated on frontal and horizontal plane platforms with two separate target boards. While the device is found to be a moderately reliable and highly valid method of measuring servical C.J.S. in the horizontal platform (r = 0.82-0.84; ICC = 0.67-0.73); measurements in the frontal plane were found to be a moderately reliable and low valid method (ICC = 0.59-0.50; r = 0.22-0.21). Interrater reliability of device was found to be good (ICC = 0.89-0.80). According to the results obtained; AOS PropPoint® device was found to be a valid and reliable method for cervical joint proprioception measurements.

Benzer Tezler

  1. The effects of connective tissue manipulation on balance and proprioception among healthy individuals

    Sağlıklı bireylerde konnektif doku masajının denge ve propriyosepsiyon üzerine etkisi

    ÇİÇEK DUMAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Fizyoterapi ve RehabilitasyonYeditepe Üniversitesi

    Fizyoterapi ve Rehabilitasyon Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FEYZA ŞULE BADILLI DEMİRBAŞ

  2. Kronik boyun ağrısının propriyosepsiyon ve skapular diskinezi üzerine etkileri

    The effect of proprioception and scapular diskinesis in chronic neck pain

    CEYDA ALYAZ HOTAMIŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Fizyoterapi ve Rehabilitasyonİstanbul Medipol Üniversitesi

    Fizyoterapi ve Rehabilitasyon Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ SERPİL ÇOLAK

  3. Farklı yaş gruplarında servikal eklem pozisyon hatası, denge ve reaksiyon zamanının incelenmesi

    Investigation of cervical joint position error, balance and reaction time in different age groups

    MUHAMMED SAİD ULUPINAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Fizyoterapi ve RehabilitasyonBolu Abant İzzet Baysal Üniversitesi

    Fizik Tedavi ve Rehabilitasyon Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ AYŞE NERİMAN NARİN

    DOÇ. DR. AYLA GÜNAL

  4. Sağlıklı bireylerde servikal ve torakal bölgeye uygulanan kayropraktik manipülasyonun otonom sinir sistemi ve solunum parametreleri üzerine anlık etkisinin karşılaştırılması

    A comparison of the immediate effect of chiropractic manipulation applied to the cervical and thoracic region on autonomic nervous system and respiratory parameters in healthy individuals

    TURAN YILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Fiziksel Tıp ve RehabilitasyonBahçeşehir Üniversitesi

    Fizyoterapi ve Rehabilitasyon Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HANDE BAŞAT

  5. Sağlıklı bireylerde servikal ve sakroiliak ekleme uygulanan kayropraktik HVLA manipülasyonunun pedobarografik analize ve otonom sinir sistemine olan anlık etkisinin karşılaştırılması

    Comparison of the immediate effect of chiropractic HVLA manipulation of the cervical and sacroiliac joints on pedobarographic analysis and autonomic nervous system in HEALTHY individuals

    HAYRİYE TURGUT

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Fizyoterapi ve RehabilitasyonBahçeşehir Üniversitesi

    Fizyoterapi ve Rehabilitasyon Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ SEFA HAKTAN HATIK