Geri Dön

Radyoterapide volümetrik modüle edilmiş ark tedavisi planlarının optimizasyonunda 'photon optimizer' algoritmasının 'aperture shape controller' özelliğinin kullanımının etkileri

The effects of using the aperture shape controller feature of photon optimizer algorithm in optimization of volumetric modulated ARC therapy plans in radiotherapy

  1. Tez No: 641109
  2. Yazar: BAŞAK GÖKSEL
  3. Danışmanlar: PROF. DR. AYŞE NUR DEMİRAL, DR. ÖĞR. ÜYESİ HAKAN EPİK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Physics and Physics Engineering, Oncology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 149

Özet

Amaç: Çalışmamızda baş-boyun, akciğer ve prostat kanserli hastaların Volümetrik Modüle edilmiş Ark Tedavisi (VMAT) RT planlarında,“Photon Optimizer”(PO) algoritması ile optimizasyonda“Aperture Shape Controller”(ASC) özelliğinin kullanılmasının tedavi plan kalitesi (TPK), tedavi verme etkinliği (TVE) ve hesaplanan ve verilen doz dağılımı arasındaki uyum (QA) üzerine etkisinin incelenmesi amaçlandı. Hipotez: ASC kullanımının kullanılmamasına göre TPK, TVE ve QA açısından daha üstün olacağıdır. Gereç-Yöntem: Definitif RT planı yapılmış olan toplam 36 (akciğer, baş-boyun ve prostat kanserli 12'şer) hasta çalışma grubu olarak seçildi. Tamamı VMAT tekniğiyle yeniden tedavi planları hazırlanıp, PO algoritması ile optimize edildi. Her bir olguda, ASC özelliğinin 3 farklı düzeyi (1. kapalı, 2. orta, 3. çok yüksek) seçilerek optimizasyon yapıldı.“ArcCheck”ile her hastada her bir plana özgü Kalite Güvenirliği (QA) değerlendirilmesi yapıldı. TPK (Homojenite İndeksi(HI), OAR doz-volüm parametreleri(DVP)), TVE (Ortalama Açıklık Aralığı(AA), Modülasyon Karmaşıklık Skoru(MCS), toplam Monitor Unit(MU)) ve QA yönünden ASC düzeylerinin ikili karşılaştırmaları“Wilcoxon Signed-Rank”testiyle yapıldı. Bulgular: TPK: Baş-boyun ve prostat kanserinde tüm PTV'ler için HI yönünden en homojen doz dağılımı ASC Kapalı olduğunda sağlanmaktadır. OAR: Beyin sapı, sağ koklea, toplam parotis, sağ parotis, sol ve sağ optik sinir, akciğer, barsak, sol femur başı ve mesane DVP'nde ASC düzeyi değiştiğinde anlamlı farklar ortaya çıkmıştır. TVE: Baş-boyun kanserinde sadece MCS, akciğer ve prostat kanserinde ise AA, MCS ve toplam MU değerlerinde ASC düzeyi değiştiğinde anlamlı fark bulunmuştur. QA: Tüm olgularda ASC düzeyi değişimiyle anlamlı fark gözlenmiştir.2 Sonuç: Baş-boyun, akciğer ve prostat kanserli hastaların VMAT planlanmasında, ASC kullanımında çok yüksek düzey ile kapalı+orta düzeye kıyasla TVE ve QA açısından olumlu sonuçlar elde edilmektedir.

Özet (Çeviri)

Aim: In this study, it was aimed to investigate the effect of using“Aperture Shape Controller”(ASC) feature in the optimization with“Photon Optimizer”(PO) algorithm in“Volumetric Modulated Arc Therapy”(VMAT) RT plans of head and neck, lung, and prostate cancer patients in terms of treatment plan quality (TPQ), treatment delivery efficiency (TDE), and agreement between calculated and delivered dose distribution (QA). Hypothesis: The use of ASC feature in optimization will be superior in terms of TPQ, TDE, and QA. Material-Method: A total of 36 patients (each 12 with head and neck, lung, and prostate cancer) with a definitive RT plan were selected as the study group. Treatment plans were reprepared with full VMAT technique and optimized with the PO algorithm. In each case, optimization was performed by selecting 3 different levels of ASC feature (1. off, 2. medium, 3. very high). In order to test the dosimetric acceptability of each RT plan prepared, patient-specific Quality Assurance (QA) was evaluated with“ArcCheck”. Comparisons of different ASC levels were performed using“Wilcoxon Signed-Rank”test (two related samples test) in terms of TPQ (Homogeneity Index (HI), OAR dose-volume parameters (DVP)), TDE (Average Open Aperture (AA), Modulation Complexity Score (MCS), Total Monitor Unit (MU)), and QA. Results: TPQ: The most homogeneous dose distribution in terms of HI for all PTVs in head and neck and prostate cancer is provided when the ASC level was off. OAR: As the ASC level was changed, significant differences were observed in the DVPs of brainstem, right cochlea, total parotid, right parotid, left and right optic nerve, lung, intestine, left femoral head and bladder. TDE: There was a significant difference only in MCS in head and neck cancer while in AA, MCS and total MU values in lung and prostate cancers.4 Conclusion: In the VMAT planning of patients with head and neck, lung and prostate cancer, the use of very high level of ASC is more favorable compared to the closed + medium level in terms of TDE and QA.

Benzer Tezler

  1. Nazofarenks kanserli hastaların radyoterapisinde helikal tomoterapi ve volümetrik ark tedavi tekniklerinin dozimetrik karşılaştırılması

    Dosimetric comparison of helical tomotherapy and volumetric arc therapy techniques in radiotherapy of patients with nasopharynx cancer

    FATMA CERİT AVCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Fizik ve Fizik Mühendisliğiİstanbul Aydın Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FÜSUN ÇETİN

    DR. ÖĞR. ÜYESİ AYDIN ÇAKIR

  2. Farklı anatomik bölgelerin radyoterapi tedavisinde hibrit tedavi tekniğinin optimizasyonu

    Optimization of hybrid treatment technique in radiotherapy treatment of different anatomic regions

    YÜCEL SAĞLAM

    Doktora

    Türkçe

    Türkçe

    2018

    BiyomühendislikYıldız Teknik Üniversitesi

    Biyomühendislik Ana Bilim Dalı

    DOÇ. DR. AYHAN BİNGÖLBALİ

  3. Menenjiom hastalarının stereotaktik radyaoterapi (SRT) tekniği ile iki farklı algoritma kullanarak yapılan tedavi planlarının dozimetrik karşılaştırılması

    Dozimetric comparison of treatment plans using two different algorithms with stereotactic radiation therapy (SRT) technique of meningiom's patients

    ESEN YILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Onkolojiİstanbul Aydın Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ KAMİL TEMİZYÜREK

  4. Evaluation of the localization accuracy of the PTV in SBRT applications using vmat technique for mobile tumours through retrospective analysis of 4D CBCT images

    Hareketli tümörler için 4D CBTC görüntülerinin retrospektif analizi ile VMAT tekniğini kullanarak SBRT uygulamalarında ptv'nin lokalizasyon doğruluğunun değerlendirilmesi

    JÜLİDE CANBULDU

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Fizik ve Fizik MühendisliğiYeditepe Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    PROF. DR. ŞERİFE İPEK KARAASLAN

    DR. ÖĞR. ÜYESİ CEMİLE CEYLAN

  5. Radyasyon onkolojisi anabilim dalında hastaya özgün yoğunluk ayarlı radyoterapi plan doğrulama verilerinin retrospektif analizi ve değerlendirilmesi

    Retrospective analysis and evaluation of patient-specific intensity-moduled radiotherapy plan verification data in the radiation oncology department

    LÜTFÜ ŞAHİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Radyasyon OnkolojisiAkdeniz Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. NINA TUNÇEL