Geri Dön

Hasarlanmış rotator manşet ve osteotendinöz bileşkeye subakromial kortikosteroid enjeksiyonu etkilerinin histolojik ve biyomekanik değerlendirilmesi: Deneysel hayvan modeli çalışması

Subacromial corticosteroid effects on the damaged rotator cuff osteotendinous junction: histological and biomechanical evaluation (Experimental animal model study)

  1. Tez No: 663085
  2. Yazar: HİKMET ŞAHİN
  3. Danışmanlar: ÖĞR. GÖR. YAVUZ AKALIN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 60

Özet

Giriş: Omuz ağrısı olan hastalarda subakromial kortikosteroid enjeksiyonu tanı ve tedavi seçeneklerinden biridir. Çalışmamızın amacı rotator manşet yırtığı oluşturulan ve onarılan sıçanlarda farklı dozlarda kullanılan kortikosteroid enjeksiyonlarının, onarılan rotator manşet bölgesi ve osteotendinöz bileşke üzerine olumlu ve olumsuz etkilerini araştırmaktadır. Gereç ve Yöntem: Güç analizi göz önünde bulundurularak toplam denek sayısı 48 olarak belirlendi. Denekler kontrol, tek doz steroid uygulanan ve dört doz steroid uygulanan olmak üzere 3 gruba ayrıldı. Gruplar biyomekanik ve histolojik çalışma için 2 alt gruba daha ayrıldı. Deneklerin supraspinatus tendonları yapışma yerinden lansetle tam kat kesilip tekrar onarıldı. Kontrol grubu için salin, tek doz grubu için tek sefer 0.6 ml/kg dozunda metilprednizolon, çok doz grubu içinse 4 hafta boyunca haftada 1 kez 0.6 ml/kg dozunda metilprednizolon enjeksiyonu subakromial alana uygulandı. Hareketleri serbest bırakılan denekler 4 hafta sonra sakrifiye edilerek; supraspinatus tendonu, skapula ve humerus tamamıyla çıkarıldı. Biyomekanik ve histolojik değerlendirme yapıldı. Biyomekanik test için skapula ve humerustan sabitlenen materyal mukavemet cihazında (instron) supraspinatus tendonu onarılan bölgeden kopana kadar 100 mm/dk sabit hızla çekildi. Veriler elektronik ortamda kaydedildi. Mikroskop görüntüleri 2 gözlemci tarafından hücre şekli ve apoptotik hücre miktarı açısından değerlendirilip 1 ile 4 arasında puanlandı (1 = daha fazla hücre sayısı ve yuvarlak şekil, 4 = daha az hücre ve iğsi şekil). Daha yüksek puan iyileşmenin daha iyi olduğunu gösteriyordu. Gözlemcilerin puanlamalarının ortalaması alındı. Bulgular: Histolojik değerlendirmede hücre şekli açısından gruplar arasında farklılık anlamlı bulunmadı (p=0.129). Apoptotik hücre miktarında ise gruplar arasında fark anlamlı bulundu (p=0.028). Apoptotik hücre miktarına bakıldığında; kontrol ve tek doz grubu arasındaki fark istatistiksel olarak anlamlı çıktı (p=0.015), kontrol ve çok doz grubu için fark istatistiksel olarak anlamlı çıktı (p=0.028), tek doz ve çok doz grubu için fark istatistiksel olarak anlamlı çıkmadı (p=1). Biyomekanik değerlendirmede maksimum gerilme açısından gruplar arasındaki farklılık anlamlı bulunmadı (p=0.305). Biyomekanik değerlendirmede kopma yükü açısından da gruplar arasındaki farklılık anlamlı bulunmadı (p=0.305). Biyomekanik paramatreler değerlendirilirken son olarak üç grup arasında enerji emilimi farklılıkları değerlendirildi ve gruplar arasındaki fark anlamlı bulundu (p=0.001). Tendonun kopması için gerekli enerji emilimi miktarına bakıldığında; kontrol ve tek doz grubu için fark istatistiksel olarak anlamlı çıktı (p=0.021), kontrol ve çok doz grubu için fark istatistiksel olarak anlamlı çıktı (p

Özet (Çeviri)

Background: Subacromial corticosteroid injection is one of the diagnostic and treatment options for patients with shoulder pain. The aim of our study was to investigate the positive and negative results of the rotator cuff tears and corticosteroid injections used at different doses in repaired rotator cuff area and osteotendinous junction in rats. Materials and Methods: Considering the power analysis, the total number of subjects was determined as 48. The subjects were divided into 3 groups as control, single dose of steroid and four doses of steroid. The groups were further divided into 2 subgroups for biomechanical and histological studies. Supraspinatus tendons of the subjects were cut in full thickness with a lancet at the tendon insertion site and repaired again. Saline for the control group, methylprednisolone at a dose of 0.6 ml / kg once for the single dose group, and methylprednisolone at a dose of 0.6 ml / kg once a week for 4 weeks for the multi dose group were administered to the subacromial area. The subjects whose movements were unrestricted were sacrificed after 4 weeks; The supraspinatus tendon, scapula and humerus were completely removed. Biomechanical and histological evaluation was done. For biomechanical testing, the material fixed from the scapula and humerus was pulled with a strength device (instron) at a constant speed of 100 mm / min until the supraspinatus tendon detached from the repaired area. The data were recorded electronically. Microscope images were evaluated by 2 observers for cell shape and amount of apoptotic cells and scored between 1 and 4 (1 = more cell number and round shape, 4 = fewer cells and spindle shape).The higher score showed better recovery. The scores of the observers were averaged. Results: In histological evaluation, there was no significant difference between the groups in terms of cell shape (p = 0.129). There was a significant difference between the groups in the amount of apoptotic cells (p = 0.028). At the amount of apoptotic cells; The difference between the control and single dose groups was statistically significant (p = 0.015), the difference was statistically significant for the control and multiple dose groups (p = 0.028), the difference was not statistically significant for the single dose and multiple dose groups (p = 1 ). In the biomechanical evaluation, the difference between the groups in terms of maximum stress was not significant (p = 0.305). Also, the difference between the groups in terms of breaking load was not significant (p = 0.305). While evaluating the biomechanical parameters, the energy absorption differences between the three groups were evaluated and the difference between the groups was found to be significant (p = 0.001). When looking through the amount of energy absorption required for the tendon to rupture; the difference was statistically significant for the control and single dose groups (p = 0.021), the difference was statistically significant for the control and multiple dose groups (p

Benzer Tezler

  1. Trombositten zengin plazmanın (PRP) yaşa bağlı olarak rotator manşet tendonu iyileşmesi üzerindeki etkileri: Ratlarda histolojik ve biyomekanik çalışma.

    Effects of platelet-rich plasma (PRP) on age-related rotator cuff tendon healing: A hi̇stologi̇cal and biomechanical study in rats.

    SHAMIL SAFARALIYEV

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Ortopedi ve TravmatolojiDokuz Eylül Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. ONUR BAŞÇI

  2. Ters omuz artroplastisinin orta dönem radyolojik ve fonksiyonel sonuçlarını etkileyen prognostik faktörler

    The prognostic factors which affect on the radiologic and functional midterm results in the reverse shoulder arthroplasty

    MECHMET CHODZA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    Ortopedi ve Travmatolojiİstanbul Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. ALİ ERŞEN

  3. Chiral metamaterial and high-contrast grating based polarization selective devices

    Kiral metamalzeme ve yüksek kontrast ızgara tabanlı polarizasyon seçici yapılar

    MEHMET MUTLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2013

    Elektrik ve Elektronik Mühendisliğiİhsan Doğramacı Bilkent Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. EKMEL ÖZBAY

  4. Obstetrik brakiyal plkeus felçli hastalarda, omuza yönelik girişimlerin etkilerinin manyetik rezonans görüntüleme ile incelenmesi

    Evaluation of the effects of the surgical procedures on obstetrical brachial plexus patients' shoulder problems with magnetic resonance imaging

    ERCAN HASSA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2012

    Ortopedi ve TravmatolojiHacettepe Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF. DR. ABDULLAH GÜRSEL LEBLEBİCİOĞLU

  5. Aspergillus niger'den pektinaz eldesi

    Pectinase production from Aspergillus niger

    BARIŞ KAYMAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    BiyolojiHacettepe Üniversitesi

    Biyoloji Ana Bilim Dalı

    PROF.DR. NİLÜFER AKSÖZ