The concordance of preoperative digital cephalometric simulation with postoperative outcomes in orthognathic surgery patients
Ortognatik cerrahi hastalarında preoperatif dijital sefalometrik simülasyonun postoperatif sonuçlarla uyumu
- Tez No: 680046
- Danışmanlar: PROF. DR. ZEYNEP AHÜ ACAR
- Tez Türü: Yüksek Lisans
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Ortognatik Cerrahi, Sefalometrik Simülasyon, Dijital ortodonti, Benzetim, Bilgisayar yazılımları, Ortodonti, Ortognatik cerrahi işlemler, Postoperatif dönem, Preoperatif dönem, Sefalometri, Orthognathic surgery, Cephalometric Simulation, Digital orthodontic, Simulation, Computer softwares, Orthodontics, Orthognathic surgical procedures, Postoperative period, Preoperative period, Cephalometry
- Yıl: 2021
- Dil: İngilizce
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
AMAÇ: NemoCeph ortodontik yazılımı tarafından üretilen bilgisayarlı ortognatik tahminleri cerrahi olarak tedavi edilen ortodontik hastalarda gerçek tedavi sonuçlarıyla karşılaştırmaktır. GEREÇ VE YÖNTEMLER: 30 ortognatik cerrahi hastasının ameliyattan 1-4 ay sonra elde edilen postoperatif sefalometrik radyografileri NemoCeph ortodontik yazılımı kullanılarak çizilmiş ve preoperatif olarak üretilen simülasyon ölçümleriyle karşılaştırılmıştır. Kullanılan parametreler SNA açısı, SNB açısı, SN-Go-Me açısı, SN-PP açısı, ANS-Me / N-Me oranı ve Ar-Go / N-Me oranıydı. Tahmin edilen ölçümler ile gerçek postoperatif ölçümler arasındaki uyumu değerlendirmek için Bland & Altman plot analizi yapılmıştır. BULGULAR: Tahmini ve gerçek ölçümler arasındaki ortalama farklar (x) ve bunların standart sapmaları (SD) aşağıdaki gibidir: SNA: x= 0.766 , SD=3.6, SNB: x=0.6667, SD=2.22, SN-Go-Me: x =0.9333, SD=3.96, Sn-PP: x=1.267, SD=2.74, ANS-Me/N- Me: x=0.3733 SD=2.21, Ar-Go/N-Me: x=0.89, SD=3.92. Ar-Go/N-Me oranı ve Sn- PP hariç, tüm parametrelerde iki ölçüm arasındaki farklar, SNA, Ar-Go/N-Me ve ANS-Me içi ortalamanın altında ve üstünde iki standart sapma içinde dağımıştır. SNA, Ar-Go/N-Me , ve ANS-Me/N-Me her birinin bir aykırı değeri, SN-Go-Me'nin üç aykırı değeri ve SN-PP'nin üç aykırı değeri varder, SNB'nin hiç değeri yoktu. SONUÇ: NemoCeph ortodontik yazılımı kullanılarak oluşturulan tahmini preoperatif sefalometrik ölçümler, cerrahi olarak tedavi edilen ortognatik hastalarda gerçek postoperatif sonuçlarla kabul edilebilir bir uyum göstermıştır. Sagital ölçümlerde uyum dikey olanlara göre daha yüksektir.
Özet (Çeviri)
AIM: To compare computerized orthognathic predictions produced by NemoCeph software with the actual outcomes in orthognathic surgery patients. MATERIAL and METHOD: We used postoperative cephalometric radiographs of 30 orthognathic surgery patients, obtained 1-4 months after surgery, that were traced using NemoCeph orthodontic software, the measurements were compared to the predicted measurements preoperative measures. The parameters used were SNA angle, SNB angle, SN-Go-Me angle, SN-PP angle, ANS-Me/N-Me ratio and Ar-Go/N-Me ratio. Bland & Altman test was used to evaluate the agreement between the simulated measurements and the actual postoperative measurements . RESULTS: The mean differences (x) and their standard deviations(SD) between the predicted and actual measurements were as follows: SNA: x= 0.766 , SD=3.6, SNB: x=0.6667, SD=2.22, SN-Go-Me: x=0.9333, SD=3.96, Sn-PP: x=1.267, SD=2.74, ANS-Me/N-Me: x=0.3733 SD=2.21, Ar-Go/N-Me: x=0.89, SD=3.92 . Except for Ar- Go/N-Me ratio and Sn-PP, the differences between the two measurements in all parameters were distributed within two standard deviations below and above the mean with SNA , Ar-Go/N-Me , and ANS-Me/N-Me each had one outlier, SNB had no outlier, SN-Go-Me and SN-PP each had three outliers . CONCLUSION: The predicted preoperative cephalometric measurements generated using NemoCeph orthodontic software showed acceptable concordance with the actual postoperative outcomes in surgically treated orthognathic patients. Concordance in sagittal measurements was higher compared to vertical ones.
Benzer Tezler
- Crowe tip 4 displastik koksartrozlarda artroplasti öncesi şablonlamanın doğruluğunun değerlendirilmesi
The accuracy of preoperative digital templating for crowe type 4 coxarthrosis arthroplasty secondary to developmental hip dysplasia
AHMET DANACI
Tıpta Uzmanlık
Türkçe
2020
Sağlık Bilimleri ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
Yükleniyor...
- Endometrium kanserinde preoperatif endometrial örnekleme, intraoperatif frozen materyali ve nihai patolojinin karşılaştırılması, frozen ve nihai patoloji arasındaki uyumu etkileyen faktörlerin araştırılması
Comparison of preoperative endometrial sampling, intraoperative frozen material, and final pathology in endometrial cancer, investigation of factors affecting the agreement between frozen and final pathology
VOLKAN ALAN
Tıpta Uzmanlık
Türkçe
2025
Sağlık Bilimleri ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
Yükleniyor...
- Kronik otitis medialı hastalarda cerrahi öncesi temporal kemik bilgisayrlı tomografi bulguları ile intraoperatif bulguların karşılaştırılması
The correlation of preoperative temporal bone computed tomography findings with intraoperative findings in chronic otitis media patients
HABİBULLAH HABİB
- Endometrium kanserinde preoperatif biyopsi sonucunun postoperatif histopatolojik grade ve evre ile ilişkisinin araştırılması
Investigation of the relationship between preoperative biopsy result and postoperative histopathologic grade and stage in endometrial cancer
ENİSE ŞEKER
Tıpta Uzmanlık
Türkçe
2019
Sağlık Bilimleri ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
Yükleniyor...
- 2010-2020 yılları arasında kliniğimizde primer hiperparatiroidi nedeniyle opere ettiğimiz hastalarda lokasyon belirlemede preoperatif yapılan görüntüleme yöntemlerinin rolü
The role of preoperative imaging methods in determining the location of patients operated for primary hyperparathyroidism in our clinic between 2010 and 2020
UMUT SERCAN ESER