Geri Dön

Kısa ve ekstra kısa dental implant destekli kantilever ve pontik dizaynına sahip sabit protezlerin farklı altyapı materyallerine göre sonlu elemanlar stres analizi ile incelenmesi

Finite element analysis of stress on short and extra short dental implant supported fixed prosthesis with cantilever and pontic design according to different superstructure materials

  1. Tez No: 702086
  2. Yazar: NURCAN KAYA
  3. Danışmanlar: DR. ÖĞR. ÜYESİ SERDAR KILIÇ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Kocaeli Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 207

Özet

Atrofik kretlerde cerrahi augmentasyon yöntemlerinin dezavantajlarının üstesinden gelebilmek amacıyla kısa ve ekstra kısa implantların kullanımı alternatif olarak görülmektedir. Bunun yanında aşırı kemik kayıplarında implantların optimum şekilde konumlandırılması ya da istenilen sayıda implantın yerleştirilebilmesinin mümkün olmadığı durumlarda pontik ya da kantilever tasarımları tercih edilebilmektedir. Aynı zamanda farklı protez materyallerinin dokularda, implant ve protetik yapıda farklı etkilerinin olması dolayısıyla kısa ve ekstra kısa implant seçeneğinde önemle değerlendirilmesi gereken faktörlerdir. Çalışmamızın amacı kısa ve ekstra kısa implantlarda pontik ve kantilever protez tasarımları ile farklı protez materyallerinin fonksiyonel kuvvetler altında kemik, implant ve üst yapı üzerindeki etkisinin incelenmesi ve karşılaştırılmasıdır. Çalışmamızda posterior mandibular bölgede 4 mm ekstra kısa ve 8 mm kısa implantlarla desteklenen üç üyeli pontik ve kantilever protez tasarımları, Cr-Co altyapı üzeri feldspatik porselen ve monolitik Zr protez materyalleri kullanılarak 8 ayrı planlama modeli oluşturuldu. Vertikal ve oblik kuvvetler sonlu elemanlar stres analizi ile değerlendirildi. Kantilever varlığında tüm yapılarda daha yüksek stresler meydana geldi. 4 mm Ekstra kısa implantlarda kortikal kemik, spongioz kemik ve implantlarda daha yüksek stres değerleri kaydedildi. Kortikal kemikte, spongioz kemikte ve dayanak bağlantı vidalarında oblik kuvvetlerde stresler artış gösterdi. Monolitik Zr protez materyalinde protetik yapıda daha yüksek stres değerleri tespit edildi. İki farklı protez materyal alternatiflerinde de implant, implant parçaları ve periimplant kemik dokuda benzer stres değerleri oluşmasına rağmen monolitik Zr protez materyaline sahip modellerde bu yapılarda az da olsa daha düşük stresler gözlendi. 4 mm Ekstra kısa ve 8 mm kısa implant destekli kantilever protez tasarımı yerine cerrahi olarak kemik elde etme yöntemleri ile pontik protez tasarımı daha uygun bulundu.

Özet (Çeviri)

In order to overcome the disadvantages of surgical augmentation methods in atrophic alveolar ridges, the use of short and extra-short implants is seen as an alternative. In addition, pontic or cantilever designs can be preferred in cases where it is not possible to position the implants optimally in excessive bone loss or to place the desired number of implants. Moreover, different prosthetic materials have different effects on tissues, implant and superstructure, so the prosthetic material is the factors that should be evaluated in the short and extra-short implant option. The aim of our study is to examine and compare the effects of pontic and cantilever prosthesis designs and different prosthetic materials on bone, implant and superstructure under functional forces in short and extra-short implants. In our study, 8 different planning models were created using three-unit pontic and cantilever prosthetic designs supported by 4 mm extra-short and 8 mm short implants in the posterior mandibular region, feldspathic porcelain with Cr-Co framework and monolithic Zr prosthetic materials. Vertical and oblique forces were evaluated with finite element analysis. Principal stress values for cortical and cancellous bone, Von Mises stress values for implant and all structures were compared. Higher stress values recorded in all structures in the presence of cantilever. Stress values increased in cortical bone, cancellous bone and implants in 4 mm extra-short implant models. The stresses in oblique forces increased in cortical bone, cancellous bone and abutment screws. Higher stress values were detected in the superstructure in the monolithic Zr prosthetic material. Although similar stress values occurred in implant, implant parts and periimplant bone tissue in two different prosthetic material alternatives, slightly lower stresses were observed in these structures in models with monolithic Zr. Instead of 4 mm extra-short and 8 mm short implant supported cantilever prosthesis design, surgical bone augmentation methods and pontic prosthesis design were found to be more suitable.

Benzer Tezler

  1. Vertikal defektli anterior maksillaya farklı uygulamalar ile yerleştirilen implantlara gelen yüklerin sonlu eleman analizi ile değerlendirilmesi

    Finite element analysis of dental implants inserted into the vertically defected anterior maxilla with different prosedures

    MELİH ÖZGEN

    Doktora

    Türkçe

    Türkçe

    2011

    Diş Hekimliğiİstanbul Üniversitesi

    Oral İmplantoloji Ana Bilim Dalı

    PROF. DR. SERDAR YALÇIN

  2. Farklı implant boyutlarıyla elde edilen kuron-implant oranlarının peri-implanter kemiğe olan etkisinin sonlu eleman analizi (FEM) ile incelenmesi

    The influence of crown-implant ratio and dental implant parameters (Diameter & Length) on implant and peri-implanter bone: A finite element analysis.

    MEHMET BAYRAKTAR

    Doktora

    Türkçe

    Türkçe

    2011

    Diş Hekimliğiİstanbul Üniversitesi

    Oral İmplantoloji Ana Bilim Dalı

    PROF. DR. SERDAR YALCİN

  3. Atrofik alt çene kemiğine uygulanan subperiosteal ve intraosseöz implantlara gelen kuvvetlerin sonlu elemanlar stres analizi yöntemi ile değerlendirilmesi

    Evaluation of the forces on subperiosteal and intraosseous implants applied to atrophic mandibular bone with finite element stress analysis method

    EKİN EZGİ BARAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiEskişehir Osmangazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. CANAN AKAY

  4. Coating of silver doped titanium by biodegradable pcl to delay antibacterial silver release in dental implants

    Diş implantlarındaki antibakteriyel gümüş salınımını geciktirmek için gümüş katkılı titanyumun biyoçözünür pcl ile kaplanması

    GİZEM ÖZGE KAYAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MOHAMMADREZA NOFAR

  5. Katodik ark elektron metal iyon işlemi ile Ni–Ti sisteminde difüzyona bağlı faz oluşumlarının incelenmesi

    Investigation of diffusion phase formations in Ni–Ti system via cathodic arc electron metal ion treatment

    NAGİHAN SEZGİN

    Doktora

    Türkçe

    Türkçe

    2018

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Malzeme Bilimi ve Mühendisliği Ana Bilim Dalı

    PROF. MUHAMMET KÜRŞAT KAZMANLI