Bilgisayarlı tomografide hasta dozunu azaltmak için kullanılan bizmut koruyucuların hasta dozu ve görüntü kalitesine etkisi
The effect of bismuth shi̇elds used to reduce patient dose in computed tomography on patient dosage and image quality
- Tez No: 703979
- Danışmanlar: DR. ÖĞR. ÜYESİ FÜSUN ÇETİN
- Tez Türü: Yüksek Lisans
- Konular: Radyoloji ve Nükleer Tıp, Radyasyon Onkolojisi, Radiology and Nuclear Medicine, Radiation Oncology
- Anahtar Kelimeler: Bilgisayarlı Tomografi, Bizmut Koruyucu, Doz Ölçümü, Görüntü Kalitesi Ölçümü, Bizmut, Görüntü kalitesi, Radyometri, Tomografi-x ışınlı-bilgisayarlı, Computed Tomography, Bismuth Preservative, Dose Measurement, Image Quality Measurement, Bismuth, Image quality, Radiometry, Tomography-x ray-computed
- Yıl: 2021
- Dil: Türkçe
- Üniversite: İstanbul Aydın Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Son 50 yıllık dönem içerisinde teknolojinin gelişmesi ve bu gelişmenin tıp alanında kullanılmaya başlanması tanı ve tedaviye büyük katkılar sağlamıştır. Radyolojide kullanılan bilgisayarlı tomografi cihazları görüntüleme alanında önemli pay sahibidir. Bu cihazlar ile yapılan çekimlerde hasta dozunu azaltmak için bizmut koruyucular kullanılmaktadır. Doz ve görüntü kalitesine etkisi olan bizmut koruyucuların kullanımı tartışılacaktır. Doz ölçümlerinde manuel ve İteratif Rekonstrüksiyon (IR) tekniğinde sabit kVp ve değişken mAs değerlerinde CTDIvol değerleri karşılaştırılacaktır. Görüntü kalitesi ölçümlerinde ise Cathpan 600 fantomunun üzerine belirli mesafelerde konulacak bizmutun çeşitli pencerelerle oluşturacağı görüntüler değerlendirilecektir. Elde edilen sonuçlar ile bizmut koruyucuların doz ve görüntü kalitesine etkisi ve kullanılmasının önemi vurgulanarak literatüre katkı sağlanacaktır.
Özet (Çeviri)
In the last 50 years, the development of technology and the use of this development in the field of medicine have made great contributions to diagnosis and treatment. Computed tomography devices used in radiology have an important share in the field of imaging. Bismuth shieldings are used to reduce the patient dose in the shots made with these devices. The use of bismuth shieldings that affect dose and image quality will be discussed. In dose measurements, CTDIvol values will be compared at constant kVp and variable mAs values in manual and Iterative Reconstruction (IR) techniques. In the image quality measurements, the bismuth placed on the Cathpan 600 phantom at certain distances images created will be evaluated. The results will contribute to the literature by emphasizing the effect of bismuth shieldings on dose and image quality and the importance of their use.
Benzer Tezler
- Bilgisayarlı tomografi çekimlerinde hasta dozunu azaltmak için kullanılan bizmut koruyucuların dna hasarı üzerine etkisi
The effect of bismuth shields on DNA damage, used for reducing patient dose at computed tomography
YAVUZ YILDIZ
Tıpta Uzmanlık
Türkçe
2013
Radyoloji ve Nükleer TıpÇanakkale Onsekiz Mart ÜniversitesiRadyoloji Ana Bilim Dalı
YRD. DOÇ. DR. OZAN KARATAĞ
- Diesel motorları yakıt püskürtme sistemlerinin dinamik simülasyonu
Başlık çevirisi yok
İRFAN KARAGÖZ
Yüksek Lisans
Türkçe
1986
Makine MühendisliğiUludağ ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. OĞUZ BORAT
- Ağızlık açma mekanizmalarının tasarımı
Başlık çevirisi yok
RECEP EREN
Yüksek Lisans
Türkçe
1987
Tekstil ve Tekstil MühendisliğiUludağ ÜniversitesiTekstil Mühendisliği Ana Bilim Dalı
DOÇ. DR. HALİL R. ALPAY
- Doğuştan kalça çıkıklı hastalarda kalça patolojilerinin bilgisayarlı tomografi ile değerlendirilmesi
Başlık çevirisi yok
NECDET ŞÜKRÜ ALTUN
Tıpta Uzmanlık
Türkçe
1987
Ortopedi ve TravmatolojiGazi ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF.DR. ORHAN ASLANOĞLU
- Kuyruk modelleri ve analizi üzerine bir uygulama
Başlık çevirisi yok
DİDEM ÖZPULAT
Yüksek Lisans
Türkçe
1985
İstatistikEge ÜniversitesiBilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı
DOÇ. DR. FİKRET İKİZ