Bilgisayarlı tomografide hasta dozunu azaltmak için kullanılan bizmut koruyucuların hasta dozu ve görüntü kalitesine etkisi

The effect of bismuth shi̇elds used to reduce patient dose in computed tomography on patient dosage and image quality

  1. Tez No: 703979
  2. Yazar: YUSUF LEVENT ERTOKTAŞ
  3. Danışmanlar: DR. ÖĞR. ÜYESİ FÜSUN ÇETİN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radyasyon Onkolojisi, Radiology and Nuclear Medicine, Radiation Oncology
  6. Anahtar Kelimeler: Bilgisayarlı Tomografi, Bizmut Koruyucu, Doz Ölçümü, Görüntü Kalitesi Ölçümü, Bizmut, Görüntü kalitesi, Radyometri, Tomografi-x ışınlı-bilgisayarlı, Computed Tomography, Bismuth Preservative, Dose Measurement, Image Quality Measurement, Bismuth, Image quality, Radiometry, Tomography-x ray-computed
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: İstanbul Aydın Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Son 50 yıllık dönem içerisinde teknolojinin gelişmesi ve bu gelişmenin tıp alanında kullanılmaya başlanması tanı ve tedaviye büyük katkılar sağlamıştır. Radyolojide kullanılan bilgisayarlı tomografi cihazları görüntüleme alanında önemli pay sahibidir. Bu cihazlar ile yapılan çekimlerde hasta dozunu azaltmak için bizmut koruyucular kullanılmaktadır. Doz ve görüntü kalitesine etkisi olan bizmut koruyucuların kullanımı tartışılacaktır. Doz ölçümlerinde manuel ve İteratif Rekonstrüksiyon (IR) tekniğinde sabit kVp ve değişken mAs değerlerinde CTDIvol değerleri karşılaştırılacaktır. Görüntü kalitesi ölçümlerinde ise Cathpan 600 fantomunun üzerine belirli mesafelerde konulacak bizmutun çeşitli pencerelerle oluşturacağı görüntüler değerlendirilecektir. Elde edilen sonuçlar ile bizmut koruyucuların doz ve görüntü kalitesine etkisi ve kullanılmasının önemi vurgulanarak literatüre katkı sağlanacaktır.

Özet (Çeviri)

In the last 50 years, the development of technology and the use of this development in the field of medicine have made great contributions to diagnosis and treatment. Computed tomography devices used in radiology have an important share in the field of imaging. Bismuth shieldings are used to reduce the patient dose in the shots made with these devices. The use of bismuth shieldings that affect dose and image quality will be discussed. In dose measurements, CTDIvol values will be compared at constant kVp and variable mAs values in manual and Iterative Reconstruction (IR) techniques. In the image quality measurements, the bismuth placed on the Cathpan 600 phantom at certain distances images created will be evaluated. The results will contribute to the literature by emphasizing the effect of bismuth shieldings on dose and image quality and the importance of their use.

Benzer Tezler

  1. Bilgisayarlı tomografi çekimlerinde hasta dozunu azaltmak için kullanılan bizmut koruyucuların dna hasarı üzerine etkisi

    The effect of bismuth shields on DNA damage, used for reducing patient dose at computed tomography

    YAVUZ YILDIZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Radyoloji ve Nükleer TıpÇanakkale Onsekiz Mart Üniversitesi

    Radyoloji Ana Bilim Dalı

    YRD. DOÇ. DR. OZAN KARATAĞ

  2. Diesel motorları yakıt püskürtme sistemlerinin dinamik simülasyonu

    Başlık çevirisi yok

    İRFAN KARAGÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. OĞUZ BORAT

  3. Ağızlık açma mekanizmalarının tasarımı

    Başlık çevirisi yok

    RECEP EREN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Tekstil ve Tekstil MühendisliğiUludağ Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HALİL R. ALPAY

  4. Doğuştan kalça çıkıklı hastalarda kalça patolojilerinin bilgisayarlı tomografi ile değerlendirilmesi

    Başlık çevirisi yok

    NECDET ŞÜKRÜ ALTUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Ortopedi ve TravmatolojiGazi Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF.DR. ORHAN ASLANOĞLU

  5. Kuyruk modelleri ve analizi üzerine bir uygulama

    Başlık çevirisi yok

    DİDEM ÖZPULAT

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    İstatistikEge Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    DOÇ. DR. FİKRET İKİZ