An evaluation on the effect of the MIR appliance on the force resistance and stability of mini screws of different lengths and diameters

MIR apareyinin farklı uzunluk ve çaptaki minividaların kuvvet direnci ve stabilitesine olan etkisinin değerlendirilmesi

  1. Tez No: 714218
  2. Yazar: ILGAZ ÖZER
  3. Danışmanlar: PROF. DR. DİDEM NALBANTGİL
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Minivida, MİR aparatı, stabilite, kuvvet direnci, vida çapı, vida uzunluğu, Mini screw, MIR appliance, stability, force resistance, screw diameter, screw length
  7. Yıl: 2022
  8. Dil: İngilizce
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 95

Özet

Çalışmamızın amacı, in vitro ortamda MIR apareyinin farklı uzunluk ve çaptaki minividalarla beraber kullanıldıklarında kuvvet direnci ve stabilizasyona olan etkisinin araştırılmasıdır. Çalışmamızda 1,4 mm çapında 6 mm uzunluğunda 20 adet, 1,4 mm çapında 8 mm uzunluğunda 20 adet, 1,6 mm çapında 6 mm uzunluğunda 20 adet, 1,6 mm çapında 8 mm uzunluğunda 20 adet, 1,8 mm çapında 6 mm uzunluğunda 20 adet, 1,8 mm çapında 8 mm uzunluğunda 20 adet olmak üzere toplam 120 adet TM (Trimed, Ankara, Türkiye) minivida kullanılmıştır. Bu araştırmada, konik yapıda olan TM minividalar tercih edilmiştir. TM minividalar, ''Self- drilling'' özelliğe sahiptir ve titanyumdan üretilmişlerdir. MİR uygulanmayan diğer grup ise kontrol grubu olarak kullanılmıştır. Minividalar, laboratuvar ortamında, sığır kalça kemiğinden elde edilen örneklere tork ölçer tornavida (N2DPSK, Nakamura MFG Co Ltd, Tokyo, Japan) ile uygulanmış ve maksimum uygulama torku (MUT) değerleri ölçülmüştür. Daha sonra, Instron test cihazı ile minivida uzun eksenine dik yönde kuvvet uygulanarak, 0,6 mm yer değiştirene kadar gösterdikleri direnç değerleri kaydedilmiştir. Kuvvet testi uygulanmış minividaların mobilitelerinin değerlendirilmesini takiben minividalar tork ölçer tornavida ile maksimum çıkarma torku (MÇT) ölçülerek kemikten çıkarılmıştır. Yapılan istatistiksel analizde MİR aparatı kullanılan minividalarda uygulama torkları artmıştır ve bu artış istenen seviyeleri aşmamıştır. Çıkarma torklarında da anlamlılık seviyesinde olmayan bir artış kaydedilmiştir. Bu sonuçlar, MİR aparatının özellikle daha küçük çaplı minividaların kuvvet direncini ve stabilitesini belli ölçülerde arttırmada etkili olduğunu ortaya koymaktadır. Yapılan araştırma sonucunda MİR aparatı, minivida primer stabilitesi ve kuvvet direncini arttırmasından dolayı özellikle kortikal kemiğin ince olduğu veya daha küçük çaplı minivida tercih edildiği vakalarda iyi bir seçenek olarak tavsiye edilmektedir.

Özet (Çeviri)

The present study aims to investigate the effect of the mini-implant ring (MIR) appliance on force resistance and stabilization when used in vitro with mini screws of different lengths and diameters. A total of 120 TM (Trimed, Ankara, Turkey) mini screws, including 20 pieces of 1.4 mm diameter and 6 mm length, 20 pieces of 1.4 mm diameter and 8 mm length, 20 pieces of 1.6 mm diameter and 6 mm length, 20 pieces of 1.6 mm diameter and 8 mm length, 20 pieces of 1.8 mm diameter and 6 mm length, and 20 pieces of 1.8 mm diameter and 8 mm length were used for the study. Titanium TM mini screws with a conical structure and“self-drilling”feature were preferred in the study. The other group in which the MIR was not applied was used as the control group. Mini screws were applied to samples obtained from bovine hip bones, in the laboratory using a torque screwdriver (N2DPSK, Nakamura MFG Co Ltd, Tokyo, Japan) and maximum application torque (MAT) values were measured. Then, by applying force perpendicular to the long axis of the mini screw with an Instron tester, the resistance values of the mini screws up to a 0.6 mm displacement were recorded. Following the evaluation of the mobility of the force-tested mini screws, the mini screws were removed from the bone by measuring their maximum extraction torques (MET) with a torque meter screwdriver. The statistical analysis showed that application torques increased in mini screws to which the MIR appliance was applied, and this increase did not exceed desired levels. A nonsignificant increase in extraction torques was also recorded. These results show that the MIR apparatus is effective in increasing the force resistance and stability particularly of smaller diameter mini screws to a certain extent. As a result of the research, the MIR apparatus is recommended as a good option, especially in cases where the cortical bone is thin or a smaller diameter mini screw is preferred, since it increases the primary stability and force resistance of the mini screw.

Benzer Tezler

  1. Erscheinungsform des Islam im Baburname

    Başlık çevirisi yok

    MESUT AVCI

    Doktora

    Almanca

    Almanca

    2015

    DinFreie Universität Berlin

    PROF. DR. CLAUS SCHONIG

    PROF. DR. BARBARA KELLNER-HEINKELE

  2. Kemoterapi alan hastaların apopitozis markılerı, tümör belirteçleri, mikro RNA düzeyleri ile klinik, laboratuar ve radyolojik görüntüleme verileri açısından değerlendirilmesi

    Assessment of apoptosis markers, tumor markers, microRNA levels, clinical, laboratory and radiological imaging data of patients taking chemotherapy patients

    FEHMİ KAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    OnkolojiHarran Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ İDRİS KIRHAN

  3. Pankreatik duktal adenokarsinoma hücrelerinde miRNA'nın, otofaji üzerinde düzenleyici etkisinin değerlendirilmesi

    The evaluation of regulatory effect of mirna on autophagy in pancreatic ductal adenocarcinoma cells

    HAFİZE ELİF SÖNMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Tıbbi BiyolojiSüleyman Demirel Üniversitesi

    Tıbbi Biyoloji Ana Bilim Dalı

    DOÇ. DR. NİLGÜN GÜRBÜZ

  4. Üretra darlığı modelinde PRP'nin tedavi edici etkisinin değerlendirilmesi

    Evaluation of the therapeutic effect of PRP in the urethral stricture model

    GÖKHAN TEMELTAŞ

    Doktora

    Türkçe

    Türkçe

    2021

    Histoloji ve EmbriyolojiManisa Celal Bayar Üniversitesi

    Histoloji ve Embriyoloji Ana Bilim Dalı

    PROF. DR. MAHMUT KEMAL ÖZBİLGİN

  5. Nöroendokrin özellikler gösteren primer invaziv meme karsinomlarında, nöroendokrin diferansiasyon yaygınlığının mikroRNA 21 ve mikroRNA let7f ekspresyonu yanı sıra klinikopatolojik parametreler ile ilişkisi

    The association of extent of neuroendocrine differentiation with microRNA 21 and microRNA let7f expression and the clinicopathological parameters in primary invasive breast carcinomas with neuroendocrine features

    GAMZE USUL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2020

    PatolojiSağlık Bilimleri Üniversitesi

    Patoloji Ana Bilim Dalı

    DOÇ. DR. ESRA CANAN KELTEN TALU