Geri Dön

Eklemeli üretim yönteminde kullanılan CO-CR içerikli alaşımların tekrar kullanımının metal-seramik bağlantı dayanımı ve mikro yapıya etkisinin değerlendirilmesi

The effect of CO-CR powder reuse by additive manufacturing method on metal-ceramic bond strength and microstructure

  1. Tez No: 715393
  2. Yazar: ISLAM GULUZADE
  3. Danışmanlar: DR. ÖĞR. ÜYESİ HAYDAR ALBAYRAK
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Erciyes Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 134

Özet

Günümüzde diş laboratuvarlarında Seçici Lazer Ergitme (SLE) yönteminde Co-Cr-W tozu elendikten sonra tekrardan kullanılmaktadır. Bu çalışmanın amacı, bir SLE yönteminde kullanılan Co-Cr-W alaşım tozunun tekrar kullanımının Metal-Seramik (MS) bağlantı dayanımı ve mikro yapıya etkisinin değerlendirilmesidir. Bu çalışmada döküm (Grup D), SLE ile hiç kullanılmamış tozdan (Grup LS-1) ve 25 defa kullanılmış tozdan (Grup LS-2) toplamda 75 adet metal altyapı üretilmiştir. Döküm çekirdeği, hiç kullanılmamış ve 25 defa kullanılmış Co-Cr tozu bir Alan Emisyonlu Taramalı Elektron Mikroskobunda (FE-SEM) ve X Işını Difraktometresinde (XRD) incelendi. Bunlardan 45 adet numune 25mmx3mmx0,5mm boyutlarında (ISO 9693) ve 30 adet 20mmx20mmx1mm boyutlarında üretilmiştir. Her gruptan 13 metal altyapının orta bölgesine (8mmx3mmx1,1mm) porselen işlenmiş ve 10 tanesinin MS bağlantı dayanımı ISO 9693 standartlarına göre belirlenmiştir. Geri kalan porselen işlenmiş 3 numune Enerji Dağılım Spektrometresi (EDS) çizgi ve alan analizleri ile karakterize edildi. Porselen işlenmemiş 2 metal altyapı hem metal mikroskobunda hem de FE-SEM incelendi. Her gruptan 20mmx20mmx1mm boyutlarındaki 10'ar numune ayna parlaklığına ulaştırıldıktan sonra XRD ile incelendi. Her bir numunenin Yüz Merkezli Kübik (YMK) faz yüzdesi XRD verileri kullanılarak hesaplandı. 25 defa kullanılmış Co-Cr-W tozunun tanecik boyutu(14,1 µm) hiç kullanılmamış tozdan (12,24 µm) daha yüksekti ve mikro yapılarında YMK fazı baskındı. Tek yönlü varyans analizi (α=0,05) sonuçlarına göre gruplar (D=29,95 MPa; LS-1=31,32 MPa; LS-2=29,89 MPa) arasında MS bağlantı dayanımı açısından istatistiksel olarak anlamlı bir fark gözlenmemiştir (P>0,05). Gruplar arasında YMK faz yüzdeleri (D=62,11; LS-1=70,82; LS-2=68,43) açısından istatistiksel olarak anlamlı fark gözlemlenmiştir (P

Özet (Çeviri)

Today, Co-Cr-W powder is reused after sieving in the Selective Laser Melting (SLM) method in dental laboratories. The aim of this study is to evaluate the effect of reuse of Co-Cr-W alloy powder used in an SLM method on Metal-Ceramic (MC) bond strength and microstructure. In this study, a total of 75 metal substructures were produced from casting (Group D), SLM and virgin powder (Group LS-1) and 25 times recycled powder (Group LS-2). The castable ingot, virgin and 25-times-recycled Co-Cr powder were examined in a Field Emission Scanning Electron Microscope (FE-SEM) and X-Ray Diffractometer (XRD). While 45 of the specimens had dimensions of 25mmx3mmx0.5mm, 30 of the specimens were produced with dimensions of 20mmx20mmx1mm. The ceramic was applied to the central region (8mmx3mmx1.1mm) of 1 side of 13 metal substructures from each group, and the MS bond strength of 10 of them was determined according to ISO 9693 standards. The remaining 3 porcelain-applied specimens were characterized by Energy Distribution Spectrometer (EDS) line-scan and field analysis. The remaining two metal frameworks in each group without the porcelain application were examined by using the metal microscope and FE-SEM. Ten specimens from each group with dimensions of 20mmx20mmx1mm were examined by XRD after polished to a mirror finished. Face Centric Cubic (FCC) phase percent of each specimen was calculated using XRD data. The particle size (14.1 µm) of the 25 times recycled Co-Cr-W powder was higher than the virgin powder (12.24 µm) and the FCC phase content was dominant the microstructure of these powders. According to the results of one-way analysis of variance (α=0.05), no statistically significant difference was observed between the groups (D=29.95MPa; LS-1=31.32MPa; LS-2=29.89MPa) considering of MC bond strength (P >0.05). A statistically significant difference was observed between the groups in considering of FCC phase percentages (D=62.11; LS-1=70.82; LS-2=68.43) (P

Benzer Tezler

  1. Kobalt esaslı alaşımların eklemeli imalat ile üretimi ve özelliklerinin incelenmesi

    Manufacturing of cobalt-based alloys by additive manufacturing and investigation of thei̇r properties

    FARUK MISIRLIOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Mühendislik BilimleriErciyes Üniversitesi

    Endüstriyel Tasarım Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FATMA NAZLI SARI

  2. Eklemeli üretim yönteminde kullanılan lazer cihazı gücünün, metal porselen bağlantı dayanımı ve metalin mikro yapısına etkisinin değerlendirilmesi

    Evaluation of the effect of laser power used in the additive manufacturing method on metal porcelain bond strength and micro structure of metal

    HÜSEYİN OZAN TEMİZKANLI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiErciyes Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HAYDAR ALBAYRAK

  3. Co-Cr alaşımının eklemeli imalat ve basınç destekli sinterleme ile üretimi ve karakterizasyonu

    Production and characterization of Co-Cr alloy by additive manufacturing and pressure-assisted sintering

    MERTCAN KIRAÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Metalurji MühendisliğiKocaeli Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    DOÇ. DR. RIDVAN YAMANOĞLU

    DR. ÖĞR. ÜYESİ GÖKHAN ÖZER

  4. Farklı lazer gücü ve tarama hızlarında slm ile üretilen metal altyapıların porselen bağlantı dayanımlarının incelenmesi

    Investigation of the porcelain bond strength of metal frameworks manufactured by slm with different laser power and scanning speed

    BETÜL KARAHASAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiSivas Cumhuriyet Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. DERYA ÖZDEMİR DOĞAN

  5. Eklemeli imalatla üretilmiş titanyum altyapıların kırılma dayanımlarının ve marjinal uyumlarının in vitro olarak değerlendirilmesi

    In vitro evaluation of fracture strength and marginal fit of titanium substructures produced by additive manufacturing

    SEVİLCAN PERÇİN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiAfyonkarahisar Sağlık Bilimleri Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ NERGİZ UZ