Farklı malzeme ve tekniklerin implant üstü ölçü hassasiyetine etkisinin konik ışınlı bilgisayarlı tomografi ile incelenmesi
Evaluation of the effect of different materials and techniques on implant impression accuracy by cone beam computed tomography
- Tez No: 728094
- Danışmanlar: DOÇ. DR. IŞIL SARIKAYA
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental implantasyon, Dental implantlar, Dental protez-implant destekli, Konik ışınlı bilgisayarlı tomografi, Poliviniller, Ölçüm teknikleri, Dental implantation, Dental implants, Dental prosthesis-implant supported, Cone-beam computed tomography, Polyvinyls, Measurement techniques
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Tokat Gaziosmanpaşa Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı farklı malzeme ve tekniklerin, alınan ölçülerin mesafe ve açı parametreleri karşılaştırılarak ölçü hassasiyetine etkisini değerlendirmektir Gereç ve yöntem: Ölçüler, birbirine paralel yerleştirilmiş 4 implant bulunan akrilik alt çene modeli üzerinden polivinil siloksan (PVS) ve polivinil siloksan eter (PVSE) ölçü materyalleri kullanılarak açık kaşık (AK) ve kapalı kaşık (KK) teknikleri ile alınmıştır. Elde edilen ölçüler konik ışınlı bilgisayarlı tomografi ile taranmış ve OnDemand3D programı ile görüntülenerek ölçümler yapılmıştır. Analoglar ve postlar arasında doğrusal mesafeler ve analog-post komplekslerinin birbirlerine göre açılanmaları ölçülmüştür. Elde edilen veriler referans model görüntüsüyle karşılaştırılmıştır. Normal dağılım göstermeyen değişkenlerin ikili karşılaştırmalarında Mann-Whitney U testi, çoklu grup karşılaştırmalarında Kruskal-Wallis-H testi kullanılmıştır. Bulgular: Analoglar ve postlar arası doğrusal mesafe ölçümlerinde gruplar arası anlamlı düzeyde fark bulunamamıştır. Açısal sapma değerlerinde AK-PVS grubu KK-PVS ve KK-PVSE değerlerine göre anlamlı fark göstermiştir (p<0.05). En az açısal sapma AK-PVS grubunda görülürken (0,195° ± 0,145°), en fazla açısal sapma KK-PVSE de görülmüştür (0,407° ± 0,507°). İmplantlar arası mesafeyle ölçü doğruluğu arasında bir ilişki görülmemiştir. Sonuç: Açık kaşık tekniği, kapalı kaşık tekniğine göre, PVS ölçü materyali PVSE'ye göre daha iyi sonuçlar vermiştir. Açık kaşık ölçü tekniği her iki ölçü materyali için benzer v sonuçlar verirken, kapalı kaşık kullanılan ölçülerde PVS ölçü materyali daha doğru ölçü vermiştir.
Özet (Çeviri)
Aim: The aim of this study is to evaluate the effect of different materials and techniques on the measurement accuracy by comparing the distance and angle parameters of the impressions. Material and Method: Impressions were taken using polyvinyl siloxane (PVS) and polyvinyl siloxane ether (PVSE) impression materials using open tray (AK) and closed tray (KK) techniques on an acrylic mandible model with 4 implants placed parallel to each other. Impressions were scanned with cone-beam computed tomography and displayed with OnDemand3D program and measurements were made. Linear distances between analogs and posts and angulations of analog-post complexes relative to each other were measured. The obtained data were compared with the reference model image. Mann-Whitney U test was used for pairwise comparisons of non-normally distributed variables, and Kruskal-Wallis-H test was used for multi-group comparisons. Results: There was no significant difference between the groups in linear distance measurements between analogs and posts. In angular deviation values, AK-PVS group showed a significant difference compared to KK-PVS and KK-PVSE values (p<0.05). The lowest angular deviation was observed in the AK-PVS group (0.195° ± 0.145°), while the highest angular deviation was observed in the KK-PVSE (0.407° ± 0.507°). There was no correlation between the distance between the implants and the measurement accuracy. vii Conclusions: The open tray PVS showed better results than the closed tray PVS and, close tray PVSE. While the open tray impression technique showed similar results for both impression materials, the PVS impression material gave more accurate impressions in the impressions using closed trays.
Benzer Tezler
- Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi
Kinetic study and detesmination of thermodnamic parameters of some esters
İBRAHİM TAŞ
- İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar
Başlık çevirisi yok
BAHAR TÜRKYILMAZ
- Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri
The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia
HALUK TOKUÇOĞLU
- Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri
Başlık çevirisi yok
GÖNÜL VAROL