İki kanallı analog elektrookülogram (EOG) veri alma devresi tasarımı ve uygulaması
Two channel analogue electrooculogram (EOG) data acquisition circuit design and implementation
- Tez No: 747659
- Danışmanlar: DR. ÖĞR. ÜYESİ SELİM ARAS
- Tez Türü: Yüksek Lisans
- Konular: Biyomühendislik, Elektrik ve Elektronik Mühendisliği, Bioengineering, Electrical and Electronics Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Ondokuz Mayıs Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 59
Özet
EOG gözün korneası ile retinası arasındaki potansiyel farkı ölçmeye yarayan elektrfizyolojik bir yöntemdir. Gözlerini kolaylıkla hareket ettirebilen hastalarda Elektrookülografi (EOG) sinyallerinin kullanılması diğer biyoelektrik sinyallere göre daha kolaydır. Bu çalışmada gözün hareketleriyle oluşan EOG sinyallerini ölçebilen özgün bir veri alma devresi tasarımı ve İBA'da kullanılmak üzere bir iletişim arayüzü tasarımı sunulmuştur. Sistem yatay ve dikey göz hareketlerini algılayacak şekilde 2 kanallı olarak tasarlanmıştır. Gözün çevresine ve alın bölgesine yerleştirilen 5 adet elektrot ile EOG sinyalleri algılanabilmektedir. Elde edilen sinyaller kuvvetlendirme, filtreleme ve son olarak gerilim seviye kaydırma biriminden geçerek gerçek zamanlı olarak mikrodenetleyiciye aktarılmaktadır. Alınan ve işlenen EOG sinyalleri Matlab uygulamasında gerçek zamanlı olarak görüntülenmiş ve yazılım ile oluşturulan iletişim arayüzünün kontrolü sağlanmıştır. Sistem kullanımından önce, tasarlanan devre üzerinden kullanıcılara uygun kazanç ayarı ve ön kalibrasyon yapılarak iletişim arayüzünün kontrolünü sağlayacak göz hareketlerinin sınıflandırması yapılmıştır. İletişim arayüzünün menü sınırında kaymalara izin verilerek komut seçimi maksimum dört adım olacak şekilde tasarım yapılmıştır. Araştırmada elde edilen sonuçlara göre sistem dört yöne bakma hareketini ortalama %97'lik bir başarım ile, göz kırpma hareketini ise ortalama %92'lik başarı ile tespit etmiştir. 5 gönüllü denek ile yapılan denemeler de ise iletişim arayüzü kullanımı sırasında bir seçim adımı ortalama 3,87 saniyede gerçekleşmektedir.
Özet (Çeviri)
EOG is an electrophysiological method for measuring the potential difference between the cornea and retina of the eye. Electrooculography (EOG) signals are easier to use than other bioelectric signals in patients who can easily move their eyes. In this study, a unique data acquisition circuit design that can measure EOG signals generated by eye movements and a communication interface design to be used in IBA are presented. The system is designed with 2 channels to detect horizontal and vertical eye movements. EOG signals can be detected with 5 electrodes placed around the eye and forehead. The obtained signals are transferred to the microcontroller in real time by passing through amplification, filtering and finally the voltage level shifting unit. The received and processed EOG signals were displayed in real time in the Matlab application and the control of the communication interface created with the software was provided. Before using the system, the appropriate gain adjustment and pre-calibration were made on the designed circuit, and the eye movements that would control the communication interface were classified. By allowing shifts in the menu border of the communication interface, the command selection is designed with a maximum of four steps. According to the results obtained in the research, the system detected the movement of looking in four directions with an average success of 97%, and the blinking movement with an average success of 92%. In trials with 5 volunteers, a selection step takes an average of 3.87 seconds while using the communication interface.
Benzer Tezler
- Si-Ge HBT bicmos teknolojisinde 6 bit 2 kanallı ayrık zamanlı ADC tasarımı
A 6-bit two-channel TI ADC in Si-Ge HBT bicmos technology
VUSALA ABBASOVA
Yüksek Lisans
Türkçe
2023
Elektrik ve Elektronik MühendisliğiKocaeli ÜniversitesiElektronik ve Haberleşme Mühendisliği Ana Bilim Dalı
PROF. DR. ALİ TANGEL
- A 6-bit time-interleaved asynchronous successive approximation register analog-to-digital converter with 1-bit redundancy in 90nm technology
90nm teknolojisinde ekstra 1-bit yedek bilgi ile 6-bit asenkron ayrık zamanlı ardışık yaklaşımlı örneksel sayısal çevirici
ARMAN GALİOĞLU
Yüksek Lisans
İngilizce
2017
Elektrik ve Elektronik MühendisliğiSabancı ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
PROF. DR. YAŞAR GÜRBÜZ
- Upgrading the hardware and preparation of software for a microprocessor based energy flow measuring device for steam
Mikroişlemciye dayalı bir buhar erkesi ölçüm aygıtı için donanımın iyileştirilmesi ve yazılımın hazırlanması
OĞUZ ALİ ŞENER
Yüksek Lisans
İngilizce
1990
Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
PROF. DR. ERSİN TULUNAY
- Virtual instrumentation for basic electrical and electronics laboratory
Temel elektrik ve elektronik laboratuvarları için sanal enstrumantasyon
MÜBERRA ŞİMŞEK
Yüksek Lisans
İngilizce
1998
Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
PROF. DR. MURAT AŞKAR
- Microprocessor based functional tester
Başlık çevirisi yok
ABDULLAH NADAR
Yüksek Lisans
İngilizce
1988
Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik ÜniversitesiDOÇ. DR. HASAN GÜRAN