Geri Dön

Sıkıştırılmış mühendislik dolgusu üzerindeki yüzeysel temellerin performansına hücresel dolgu uygulamasının etkisinin model deneylerle araştırılması

Investigation of the effect of geocell application to the performance of shallow foundations on compacted engineering fills with model experiments

  1. Tez No: 751806
  2. Yazar: GÖZDE TÜFEKÇİBAŞI ERDOĞAN
  3. Danışmanlar: PROF. DR. YÜKSEL YILMAZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Mühendislik Bilimleri, Civil Engineering, Engineering Sciences
  6. Anahtar Kelimeler: Dolgu, Kum, Oturma, Zemin güçlendirme, Zemin iyileştirme, Çakıl, Filling, Sand, Settlemet, Soil reinforcement, Soil improvement, Gravel
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Geoteknik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, laboratuvar ortamında; sınır şartları belirlenmiş tank içerisinde, hücre yüksekliği (100 mm) sabit tutularak farklı hücre açıklıklarını ve hücre kalınlıklarını kapsayan hücresel dolgu malzemelerinin (Geocell-33-1,5; Geocell-40-1,5; Geocell-60-1,0; Geocell-60-2,0) farklı derinliklerdeki kum veya çakıl tabakalara yerleştirilip sıkıştırılmasıyla oluşturulan model mühendislik dolgularında, dairesel plaka altında yük oturma ilişkileri incelenmiştir. Geocell hücrenin, kum içerikli mühendislik dolgularına katkılarının miktarını değerlendirmek için 14 adet model deney ve çakıl içerikli mühendislik dolgularına etkisini değerlendirmek için 8 adet model deney yapılmıştır. Beklendiği gibi artan rölatif sıkılığın hem kum hem de çakıl numunelerinde yük-oturma davranışını etkileyen en önemli değişken olduğu gözlemlenmiştir. Çakıl zeminlerde, geocellin 1.tabakaya yerleştirilmesi ve rölatif sıkılığın %44'den %66'ya çıkarılması ile temelin taşıma gücünde 1,59 kat artış ve geocellin 2.tabakaya yerleştirilmesi ve rölatif sıkılığın %46'dan ve %66'ya çıkarılması ile temelin taşıma gücünde 1,27 kat artış gözlemlenmiştir. Geocell malzemesinin temel altı zeminde varlığı, deney koşullarının Geocell donatı yerleştirme derinliğinin; 0-2/3D (model temel çapı) aralığında değişmesi durumunda yük-oturma davranışında önemli bir değişiklik görülmemiştir. Aynı koşullarda, farklı yükleme hızlarında yapılan sınırlı sayıda deneylere göre, yükleme hızının donatılı kum zemindeki yük-oturma davranışına belirgin bir etkisi olmadığı görülmüştür.

Özet (Çeviri)

In this study, in the laboratory environment; in the tank with defined boundary conditions, load-settlement relationships under the circular plate were investigated in model engineering fills, which were formed by placing and compacting cellular filling materials (Geocell-33- 1,5; Geocell-40-1,5; Geocell-60-1,0; Geocell-60-2,0) covering different cell openings and cell thicknesses, while keeping the cell height (100 mm) constant, on sand or gravel layers at different depths. 14 model experiments were conducted to evaluate the contribution of the geocell to the sand-containing engineering fills and 8 model experiments were conducted to evaluate the effects of the gravel-containing engineering fills. As expected, increasing relative compactness was observed to be the most important variable affecting load settlement behavior in both sand and gravel samples. In gravel soils, by placing the geocell in the 1st layer and increasing the relative density from 44% to 66%, the bearing capacity of the foundation increased by 1.59 times and the geocell was placed in the 2nd layer and the relative density was increased from 46% to 66%, the bearing capacity of the foundation increased by 1.59 times was observed. Presence of the Geocell material in the sub-foundation in the test conditions, the Geocell reinforcement placement depth; no significant change was observed in the load-settlement behavior when it changed in the range of 0-2/3D (model foundation diameter). According to a limited number of experiments performed under the same conditions at different loading rates, it has been observed that the loading speed does not have a significant effect on the load-settlement behavior of the reinforced sand soil.

Benzer Tezler

  1. Edirne-Kınalı Otoyolunda meydana gelen üst yapı çatlakları üzerine bir analiz

    Başlık çevirisi yok

    SEZGİN KILIÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    İnşaat MühendisliğiYıldız Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. ORAL TÜMAY

  2. Arazide kontrollü dolgu çalışmaları ile zemin taşıma gücünün arttırılması

    Soil improvement with controlled insitu fill works

    MÜRSEL AKAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    İnşaat MühendisliğiKocaeli Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. AYDIN KAVAK

  3. Yapay sinir ağları yaklaşımı ile kompaksiyon parametrelerinin tahmini

    Estimation of compaction parameters by means of artificial neural networks approaches

    YAŞAR TANER SOYCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2008

    İnşaat MühendisliğiNiğde Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. OSMAN SİVRİKAYA

  4. Regresyon yaklaşımlarla kompaksiyon parametrelerinin belirlenmesi

    Determination of compaction parameters by mens of regression approaches

    ALPER ÖLMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2007

    İnşaat MühendisliğiNiğde Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Y.DOÇ.DR. OSMAN SİVRİKAYA

  5. An experimental investigation of thermal, hydraulic and chemical effects on the erosion of compacted bentonite

    Sıkıştırılmış bentonitin erozyonu üzerindeki termal, hidrolik ve kimyasal etkilerin deneysel olarak incelenmesi

    SÜLEYMAN BÜLBÜL

    Doktora

    İngilizce

    İngilizce

    2023

    İnşaat MühendisliğiUnıversıty Of Manchester Instıtute Of Scıence And Technology (umıst)

    Geoteknik Ana Bilim Dalı

    DR. Ahmad Syed Mohd Syed