Geri Dön

Şeffaf plaklarla mini vida destekli kanin distalizasyonu uygulamalarında uzunluğu ve yapısı farklı kuvvet kollarının etkisinin sonlu elemanlar analizi ile değerlendirilmesi

Evaluation of the effect of different length and structure of force arms in miniscrew assisted canine distalization applications on clear aligner by finite element analysis

  1. Tez No: 752157
  2. Yazar: AYŞEGÜL İNAN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ MERVE GONCA
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Şeffaf plak, kuvvet kolu, kanin distalizasyon, karbon fiiber ile güçlendirilmiş kompozit, sonlu elemanlar analizi, Clear aligner, force arm, canine distalization, carbon fiber reincluded composite, finite element analysis
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Recep Tayyip Erdoğan Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Ortodonti Bilim Dalı
  13. Sayfa Sayısı: 110

Özet

Amacımız şeffaf plaklarla kanin distalizasyonunun tedavisinde farklı yapıda ve değişken uzunluktaki kuvvet kollarının kullanımının diş hareketlerine, periodontal dokuya, şeffaf plağa, kuvvet koluna, mini vidaya etkisini 3 boyutlu(3D) sonlu elemanlar analizi (SEA) ile değerlendirmektir. 1. küçük azı dişi çekilmiş, kanin dişin maksillar düzlemle 90° açısı olan, düzgün hizalı dişlere sahip erişkin bir hastaya ait dental tomografi (BT) verileri kullanılarak 3D üst çene modeli oluşturulmuştur. 3D üst çene modeli, BT verisinden 3D Slicer (BWH, MA, USA) yazılımı aracılığı ile elde edilmiştir. Katı modelleri analiz ortamına uyarlamak için ALTAIR Evolve yazılımı (ALTAIR, Troy, MI, ABD) aracılığıyla tersine mühendislik ve üç boyutlu CAD faaliyetleri kullanıldı. Optimize ağ örgüsünün gerçekleştirilmesi için ALTAIR Hypermesh (ALTAIR, Troy, MI, USA) yazılımı kullanıldı. Nastran tabanlı ALTAIR Optistruct (ALTAIR, Troy, MI, USA) implicit SEA modellerinin çözümünde kullanıldı. Çalışmamızda toplam 14 model oluşturulmuştur. İki modelde sadece 0,1 mm ve 0,2 mm şeffaf plak aktivasyonu uygulanmış, kuvvet kolu kullanılmamıştır. İki farklı plak aktivasyonuna (0,1 veya 0,2 mm), üç farklı kuvvet kolu uzunluğuna (12, 13 veya 14 mm) ve iki kuvvet kolu malzemesine (paslanmaz çelik, karbon fiber ile güçlendirilmiş kompozit) göre 12 model oluşturulmuştur. Tüm modellerde en fazla periodontal stres kanin dişin çevresinde görülmüştür. En fazla çekme stresi model 13 ve model 14'te kanin dişin mesio-bukkalinde izlenmiştir. Şeffaf plak aktivasyonu ve kuvvet koluyla distal yönlü kuvvet uygulanan modellerde kanin kronunda distale devrilme azalmış, palatinale devrilme artmıştır. En fazla distale ve palatinale devrilme 2. grupta model 13 ve 14'de; 1. grupta model 6 ve model 7'de görülmüştür. Ön keser dişlerde palatinal yönde en az devrilme model 6 ve model 7'de görülmüştür. Dişlerde yer değiştirmenin fazla olduğu bölgelere karşılık gelen plak bölgelerinde de deformasyonun fazla olduğu gözlenmiştir. Bu bölgeler kanin, kanine komşu çekim yeri ve lateral dişi kaplayan bölgelerdir. Aynı uzunluğa fakat farklı materyale sahip kuvvet kolları kanin diş hareketinde benzer sonuçlar göstermiştir. Fakat karbon fiber ile güçlendirilmiş kompozit (KFGK) yapısındaki kuvvet kolunda, paslanmaz çelik kuvvet koluna (PÇ) göre daha az stres oluşmuş, stres diş etine daha yakın konumlanmıştır. Kuvvet kollarındaki en yüksek Von Mises stres değeri model 13'te görülmüştür. Tüm modellerde mini vida üzerinde en yüksek Von Mises stresi boyun bölgesindeydi. Vidanın yerleştiği alveolar kemikte çekme stresinin en fazla olduğu bölge 2. grupta 1.gruba göre hem oklüzyona daha yakın hem daha mesialde konumlanmıştır. En fazla çekme stresi model 13 ve model 14'te izlenmiştir. Çalışmamızdaki sonuçlara göre şeffaf plaklarda kuvvet kolu uygulaması dişlerin sagital eksende paralel hareketin sağlanmasına yardımcı olmakta fakat transvers düzlemdeki devrilme miktarında artışa neden olmaktadır. Kuvvet kolu uzunluğunun artışı hem plak deformasyonu hem periodontal doku stresini arttırmaktadır. KFGK, PÇ ile kıyaslandığında diş hareketlerinde benzer sonuçlar göstermiş ayrıca iç yapısında daha az stres birikimi barındırmıştır. Ayrıca stres bölgesinin ataşmandan daha uzakta konumlanması ataşmanın daha az deformasyona uğramasına neden olabileceğinden PÇ'ye altenatif olarak kulllanılabileceği yönünde umut vaat etmektedir. Ancak bu alandaki tek çalışma olduğundan diğer çalışmalarla birlikte daha geniş bir perspektifte değerlendirilmesi gerekmektedir.

Özet (Çeviri)

Our aim was to evaluate the effects of using different structures and variable lengths of force arms in treatment of canine distalization with clear aligners via 3D finite element analysis (SEA) on tooth movements, periodontal tissue, clear aligner, force arm, miniscrew. A 3-dimensional (3D) model was created using tomography data (CT) of an adult patient with well-aligned teeth, the first premolar tooth extracted, the canine angled 90 degrees with the maxillary plane. The 3D maxillary model was obtained from the CT data via 3D Slicer (BWH, MA, USA) software. Reverse engineering and three-dimensional CAD activities via ALTAIR Evolve software (ALTAIR, Troy, MI, USA) were used to adapt solid models to the analysis environment. ALTAIR Hypermesh (ALTAIR, Troy, MI, USA was used to realize optimized mesh. Nastran-based ALTAIR Optistruct (ALTAIR, Troy, MI, USA) was used to solve implicit finite element models. 14 models were created in our study. In two models, only 0.1 or 0.2mm aligner activation was applied, power arm was not used. Another 12 models were created based on two different aligner activations (0.1 or 0.2 mm), three different power arm lengths (12, 13 or 14 mm) and two power arm materials (stainless steel or carbon fiber reincluded composite). The maximum periodontal stres was observed around the canine in all models. The highest tensile stress was observed in the mesio-buccal of the canine in models 13 and 14. Distal tipping of the canine crown decreased and palatal tipping increased in models with clear aligner activation and distally applied force with the power arm. In the model 13 and model 14 from the 2nd group, in the model 6 and model 7 from the 1st group, the most distal tipping and the most palatal tipping were observed. The least palatal tipping of anterior incisors in the palatal direction was observed in model 6 and model 7It has been observed that the deformation is high in the aligner regions corresponding to the regions where the displacement is high in the teeth. These regions were in the regions covering canine tooth, the extraction site and the lateral tooth. Different power arms of equal length showed similar results in tooth movements. However, less stress occurred in the carbon fiber reinforced composite power arm compared to the stainless steel power arm, and the stress was closer to the gingiva. The highest Von Mises stress in the power arm was seen in model 13. The highest Von Mises stress on the miniscrew in all models was in the neck region. In the alveolar bone where the screw was located the region with the highest tensile stress was located both closer to the occlusion and more mesially in 2nd group compared to 1st group. The highest tensile stress was observed in model 13 and model 14. The highest tensile stres of the screw region was observed in the model 13 and model 14. According to the results of our study, the power arm application in addition to the activation of the clear aligner helps to provide parallel movement of the teeth in the sagittal axis, but causes an increase in the amount of tipping in the transverse plane. Increasing the length of the power arm increases both aligner deformation and periodontal tissue stress. KFGK showed similar results in tooth movements when compared to PÇ, and had less stress in its internal structure. In addition, the fact that the stress region was located further away from the attachment may cause less deformation of the attachment, thus promising that it can be used as an alternative to PÇ. However, since it is the only study in this field, it should be evaluated in a wider perspective together with other studies.

Benzer Tezler

  1. Şeffaf plak ile yapılan minivida destekli en masse retraksiyon uygulamalarında farklı tasarımların etkisinin sonlu elemanlar analizi ile karşılaştırılması

    Comparison of the effect of different designs on en masse retraction applications with clear aligners using finite element analysis

    ELA EUSMANAGA

    Doktora

    Türkçe

    Türkçe

    2023

    Diş Hekimliğiİstanbul Aydın Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. AYLİN PAŞAOĞLU BOZKURT

  2. İskeletsel sınıf III hastalarda şeffaf plaklar ile ortognatik cerrahi uygulamalarının dişsel, iskeletsel, yumuşak doku ve kemik biyobelirteç değişimlerinin incelenmesi

    Evaluation of dental, skeletal, and soft tissue changesof orthognathic surgery with clear aligners inskeletal class III patients

    HÜMEYRA ÜNSAL

    Doktora

    Türkçe

    Türkçe

    2022

    Diş HekimliğiBezm-i Alem Vakıf Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. GÖKMEN KURT

  3. Minivida destekli ve şeffaf plak yöntemi ile elde edilen üst büyük azı distalizasyonun tedavi sonuçlarının karşılaştırılması

    Comparison of the upper first molar distalization treatment results obtained by miniscrew-assisted and clear aligner method

    EBRU İLHAN KOÇAK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiKırıkkale Üniversitesi

    Ortodonti Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ BERAT SERDAR AKDENİZ

  4. Şeffaf plaklarla maksiller keser retraksiyonunda farklı ankraj modellerinin sonlu eleman analizi ile incelenmesi

    Investigation of different anchorage models with finite element analysis in maxillary incisor retraction with clear aligners

    ABDULKADİR AKBAŞ

    Doktora

    Türkçe

    Türkçe

    2023

    Diş HekimliğiGazi Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. REFİA LALE TANER

  5. Şeffaf plaklarla tedavi edilen dental sınıf II vakalarda konvansiyonel ataşmanların farklı açısal değerlerde yerleştirilmesinin maksillar molar distalizasyonu üzerine etkinliğinin değerlendirilmesi

    Evaluation of the effectiveness of placing conventional attachments at different angular values ​​on maxillary molar distalization in dental class II cases treated with Clear Aligners

    RUKİYE ELİAÇIK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiAnkara Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. AYŞE TUBA ALTUĞ DEMİRALP