Geri Dön

Farklı katlara yerleştirilen sürtünmeli sönümleyicilerin yapının deprem etkisi altındaki elastik davranışına etkilerinin incelenmesi

Investigation of effects of friction dampers located on different storeys on elastic behaviour of structure under earthquake

  1. Tez No: 752894
  2. Yazar: MERT GÜRBÜZ
  3. Danışmanlar: DR. ÖĞR. ÜYESİ EMİNE AYDIN, DR. ÖĞR. ÜYESİ ELİF BORU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Deprem Mühendisliği, İnşaat Mühendisliği, Earthquake Engineering, Civil Engineering
  6. Anahtar Kelimeler: Damper, Deprem, SAP2000, Sönümleme, Sürtünme, Damper, Earthquake, SAP2000, Damping, Friction
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Sakarya Uygulamalı Bilimler Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Aktif deprem kuşağı üzerinde yer alan ülkemizde depremler sonucu önemli can ve mal kayıpları meydana gelmektedir. Maddi ve manevi kayıpları azaltmak amacıyla birçok farklı inşaa veya güçlendirme yöntemi geliştirilmiştir. Bu yöntemlerden biri de yapılarda sismik sönümleyicilerin kullanılmasıdır. Geleneksel yapı tasarımında yapının depreme karşı dayanıklılığı hesaplanırken yapıda kullanılan malzemelerin elastik davranışlarıyla beraber elastik ötesi davranışları da dikkate alınır. Yapı elemanlarının elastik ötesi davranışları kalıcı şekil değiştirmeleri arttırmaktadır. Tasarımda kalıcı şekil değiştirmelerin sınırlandırılması gerekmektedir. Sismik sönümleyiciler, yapı elemanlarının maruz kalacağı elastik ötesi şekil değiştirmeleri azaltmada etkin olarak kullanılmaktadır. Bu çalışmada sismik sönümleyici çeşitlerinden, sürtünmeli sönümleyicilerin bina deprem davranışına olan etkisi araştırılmıştır. Sürtünmeli sönümleyiciler binanın farklı katlarına yerleştirilerek davranışta meydana gelen değişim incelenmiştir. Bu amaçla iki farklı deneysel çelik bina modeli hazırlanmıştır. Tek açıklıklı modellerden biri tek katlı diğeri ise beş katlıdır. Tek katlı deneysel model, SAP2000 programında sürtünmeli sönümleyicili yapının sonlu eleman modelini doğrulamak amacıyla imal edilmiştir. Beş katlı deneysel model ise farklı katlara yerleştirilen sürtünmeli sönümleyicilerin binanın periyot ve tepe yerdeğiştirmesine olan etkisini göstermek amacıyla imal edilmiştir. Altı farklı deprem kaydı kullanılarak sarsma tablası deneyleri gerçekleştirilmiş ve sonuçlar sonlu eleman modelleriyle doğrulanmıştır. Binanın tepe noktası yerdeğiştirme değerleri karşılaştırılarak sürtünmeli sönümleyicinin en verimli olduğu yer belirlenmeye çalışılmıştır. Yapılan deney ve analizler sonucunda, sönümleyici performansının binaya etki eden depremin bağlı olarak değiştiği, sürtünmeli sönümleyicilerin katlar arası sürekli olması gerekmediği ve alt katlara yerleştirilen sürtünmeli sönümleyicilerin üst katlara yerleştirilen sönümleyicilere kıyasla bina yerdeğiştirmesini azaltmada daha etkin olduğu belirlenmiştir. Kolon kesme kuvvetlerindeki en büyük azalma ve en büyük periyot değişiminin de sürtünmeli sönümleyicilerin alt katlarda kullanıldığı durumlarda olduğu tespit edilmiştir.

Özet (Çeviri)

Significant losses of life and property occur as a result of earthquakes in our country, which is located on the active seismic belt. To decrease material and moral losses, numerous construction and retrofit methods have been developed.One of these method is using seismic damper on structures. In conventional structural design, while resistance of structure against earthquake is calculated, elastic behaviour of structural elements used in buildings are taken into account as well as their inelastic behaviour. Inelastic behaviours on structural elements increases permanent deformations. It is required that permanent deformations must be limited in design. Seismic dampers are used effectively in decreasing inelastic deformations on structural elements. In this study, effects of friction dampers that is a type of seismic dampers on structural earthquake behaviour were investigated. The change in behavior was investigated by placing friction dampers on different storeys of the building. Two distinct steel test models were manufactured for this investigation. Both of these models are single-span but one of them has one storey whereas the other has five storeys. The one-storey test model was manufactured to verify the finite element model of the friction dampers on SAP2000 programme. The five-storey test model was manufactured to demonstrate the effects of friction damper located on different storeys on the period and then top storey displacement of the building. Shake table tests were performed by using six different earthquake records and the results were verified by the finite element model. The most efficacious place of the friction damper was determined by comparing the values of the building's top-storey displacements. As a results of experiments and analyzes, it was determined that the performance of friction dampers change according to characteristics of the earthquake acting on the building, friction dampers don't need to be continuous among storeys and friction dampers placed on lower storeys decrease building displacements more than the dampers placed on upper storeys. It was also determined that maximum decrease on the column shear forces and maximum frequency change occur in the cases where friction dampers are used on lower storeys.

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  2. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  3. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Üroloji Ana Bilim Dalı

    Yükleniyor...

  4. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    Yükleniyor...