Geri Dön

Ultrases uygulamasının kabuklu yumurtanın depolama stabilitesine etkisi

The effect of ultrasound application on the storage stability of shell eggs

  1. Tez No: 757988
  2. Yazar: GÖZDE YILDIRIM
  3. Danışmanlar: PROF. DR. CENGİZ CANER, DOÇ. DR. MUHAMMED YÜCEER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Gıda Mühendisliği, Food Engineering
  6. Anahtar Kelimeler: Yumurta, ultrasonikasyon, stabilite, kalite kriterleri, Kalite özellikleri, Kararlılık, Yumurtalar, Egg, ultrasonication, stability, and quality criteria, Quality properties, Eggs
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Çanakkale Onsekiz Mart Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Gıda Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Değerli bir protein ve besin kaynağı olan taze yumurtalar sınırlı raf ömrüne sahiptir. Ultrason ve ozon gibi termal-olmayan teknikler, uzun raf-ömrü ve minimum işlenmiş gıdaların üretilmesinde dikkat çekmektedir. Bu araştırmanın amacı, farklı güçteki ultrasonikasyon proseslerinin (80W, 160W ve 360W) taze yumurtanın depolama stabilitesinin uzatılmasında kalite kriterleri üzerindeki (albümin ve yumurta sarısı pH, Haugh ünitesi, yumurta sarısı indeksi, kuru madde ve RWC) etkinliğini araştırmaktır. Taze yumurtaların, yumurta sarısı indeksi (YI) depolamada kontrolde, 0,42'den 0,27'ye düşerken, 360W, 160W ve 80W güçteki ultrases uygulamalarında sırasıyla 0,32, 0,33 ve 0,33'e düşmüştür. Haugh birimi(HU) 4 haftalık depolama sonrası 79,30'dan kontrol örneğinde 40,66'ya düşerken, 47,39 HU (360W), 46,73 (160W) ve 47,07 (80W) düşmüştür. Stabilite, başlangıç değeri 31'den (kontrol) 25-18 (ultrasonikasyon) depolama sonunda 6,5 (kontrol) 13-14'e (ultrasonikasyon) düşmüştür. Albümin pH değerleri depolama sonunda 8.67-8.84'ten (başlangıç) 9,54'e (kontrol) 9,43-9,41'e (ultrasonikasyon) ulaşmıştır. Yumurta sarısının pH değerleri 6.07'ye (kontrol) depolama sonunda 6,35 (kontrol) 6,27 (80W), 6,25 (160W) ve 6,23'e (360W) artmıştır. Albüminin kuru madde, 14.23'ten (başlangıç) depolama sonunda 16.43 (kontrol)-16,5 (360W), 16,62 (160W) ve 16,90 (80W)'a yükselmiştir. Yumurta sarısının kuru madde değerleri depolama sonunda 48.75'ten (başlangıç) 44.78'e (kontrol) -46,48 (360W), 46,26 (160W) ve 45.92'ye (80W) düşmüştür. RWC değerleri (başlangıç 932-845), depolama sonunda 725 (kontrol), 860 (360W), 847 (160W) ve 855 (80W) düşmüştür. En düşük kabuk mukavemeti, ultrasonik kavitasyon nedeniyle 360W- ultrasonikasyon yumurtalarında (4.1 (kgf)-top) gözlenmiştir. Bu çalışmadan, taze yumurtaların fonksiyonel özelliklerini (pH, HU, YI, DM ve RWC) muhafaza eden ultrasonikasyonun, gücüne bağlı olarak stabilitesini korumuştur. Yüksek ultrason (360 W) kabuk mukavemetini azaltan mikro çatlaklara yol açmıştır. Bu çalışma, taze yumurtaların depolama stabilitesinin, özellikle 80W ve 160W, kabuk mukavemetine olumsuz bir etki olmaksızın en az 1 hafta uzatıldığını göstermiştir. Ultrasonikasyon, taze yumurtaların uzun süreli depolama stabilitesinin artırılmasında uygulanabilir ve etkili bir prosestir.

Özet (Çeviri)

As a valuable source of protein and nutrients, the shelf life of fresh eggs is limited. With non-thermal techniques such as ultrasound and ozone, it attracts attention in the enhancing of shelf-life and minimally processed foods. The purpose of this study, ultrasonication process (80W, 160W and 360W) storage stability in improving quality attributes of fresh eggs (yolk and albumen ph, Haugh unit, yolk index, dry matter and RWC) is to investigate the effectiveness. The egg yolk index (YI) of the fresh eggs used in the study showed changes during storage. This change decreased from 0.42 to 0.27 for control, while it decreased by 0.32, 0.33 and 0.33 for 360W, 160W and 80W applications. The values of Haugh unit (HU), one of the parameters used in the study, showed a high change after 4 weeks of storage. The HU value decreased from 79.30 to 40.66 (control), 47.39HU (360W), 46.73 (160W) and 47.07 (80W). The stability values decreased from the initial value of 31 (control) 25-18 (ultrasonication) to 6.5 (control) 13-14 (ultrasonication) at the end of storage. Albumin pH values increased from 8.67-8.84(initial) to 9.54(control) 9.43-9.41(ultrasonication) at the end of storage. The pH values of egg yolk increased to 6.07-(initial)- 6.35 (control) 6.27 (80W), 6.25 (160W) and 6.23 (360W) at the end of storage. The dry matter of albumin increased from 14.23 (initial) to 16.43(control) -16.5(360W), 16.62(160W) and 16.90(80W) at the end of storage. Dry matter values of egg yolk decreased from 48.75(initial) to 44.78(control) -46.48(360W), 46.26(160W) and 45.92(80W) at the end of storage. RWC values (initial 932-845) were decreased to 725(control), 860(360W), 847(160W) and 855(80W) at the end of storage. The lowest shell strength, due to ultrasonic cavitation 360W-in ultrasonication eggs (4.1(kgf)-top) has been observed. From this study, it was reveal that the functional properties of fresh eggs (pH, HU, YI, DM and RWC) were preserved depending on the ultrasonication power used. High ultrasound (300W) caused micro cracks that reduced shell strength. This study showed that the storage stability of fresh eggs, especially 80W and 160W, was extended for at least 1 week without any adverse effect on shell strength. Ultrasonication can be a feasible and effective process for increasing the long-term storage stability of fresh eggs.

Benzer Tezler

  1. Elektro-osmozun katkılı ve katkısız portland çimento harçlarına etkisi

    Effect of electro-osmosis on portland cement mortars with admixture and non-admixture

    FİKRET TÜRKER

    Doktora

    Türkçe

    Türkçe

    1985

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  2. Ultrases geçiş süresi yönteminin betona uygulanması

    Application of ultrasonic pulse transit time method on concrete

    BİLGE SİYAHİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Anadolu Üniversitesi

    Yükleniyor...

  3. Volkanik cüruf yarı hafif betonların mekanik özelliklerinin kompozit malzeme kuralları ile incelenmesi

    Analysis of mechanical properties of volcanic slag semi-lightweight concrete by the rules of composite metarials

    HÜSNÜ DÖNMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    Gazi Üniversitesi

    Yapı Eğitimi Ana Bilim Dalı

    Yükleniyor...

  4. Ultrases ile katı, sıvı ve gaz ortamların fiziksel özelliklerinin incelenmesi

    Başlık çevirisi yok

    MEHMET PEKER

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    Anadolu Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  5. Determination of lead and nickel in air particulate materials

    Başlık çevirisi yok

    MOHAMMAD ALİ ANWARİ

    Yüksek Lisans

    İngilizce

    İngilizce

    1990

    Orta Doğu Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  6. Fetal ağırlığın ultrasonografi ile tahmini ve fetal büyüme parametreleri ile fetal ağırlık arasındaki ilişki

    Başlık çevirisi yok

    SADIK ÖZEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1990

    İstanbul Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    Yükleniyor...