Diz implantı polietilen ınsert yüzeyindeki aşınmanın dizdeki gerçek dinamik yüklemeler, posterior tibial açısı değişimi ve anterior-posterior öteleme ile interior-eksterior dönme etkileri altında sayısal olarak incelenmesi

Computational wear of knee implant polyethylene insert surface under effects of real dynamic loadings, posterior tibial slope variation and anterior-posterior translation with interior-exterior rotation

  1. Tez No: 784676
  2. Yazar: ÇAĞLA ÖCAL
  3. Danışmanlar: DOÇ. DR. ALAETTİN ÖZER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Yozgat Bozok Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 70

Özet

Posterior Tibial eğim açısının, Polietilen (PE) insert üzerindeki maksimum temas basıncı ve aşınma miktarı etkisi yeterince ilgi görmemiştir. Fleksiyon açısı, Anterior-Posterior (AP) öteleme miktarı, Internal-Eksternal (IE) Dönme miktarı ve tibial eğim açısının, Total Diz Artroplastisi (TDA) PE insert üzerindeki maksimum temas basıncı ve aşınması üzerindeki etkilerini belirlemek amacıyla Archard'ın aşınma kanunu ve kadavra kullanılarak doğrulanan yüklemeler altında incelenmiştir. Bu çalışma, sadece kadavra deneyleriyle doğrulanmış yük değil, aynı zamanda 0'dan 90 dereceye değişen dinamik fleksiyon kullanır. Diz implant PE insert üzerindeki aşınma, bir 3 boyutlu (3B) 2.5 numara bağ kesen total diz implant modeli ile birlikte Sonlu Elemanlar Yöntemi (SEY) ve yüklemeler ile 0'dan 90 dereceye değişen AP öteleme ve IE Dönme verileri kullanılarak araştırılmıştır. Diz implant polietilen insert üzerindeki aşınma etkilerini belirlemek için iki farklı analiz yapılmıştır. Birinci tip analizler, femur eksenine göre 0'dan 90 dereceye değişen dinamik fleksiyon açıları altında, diğerleri ise belli açılara göre yüklemeler için zamana bağlı analizlerdir. PE insert üzerindeki temas basıncının Fleksiyon, Fleksiyon + AP öteleme ve IE Dönme için devirle birlikte azaldığı belirlenmiştir. Devir arttıkça her üç durum için elde edilen aşınmanın arttığı açıktır. AP öteleme etkisi nedeniyle PE insert üzerindeki yüklemelerin düşük devirlerde yeterince etkili basınç oluşturamadığı bu nedenle aşınmayı azaltıcı etki yaptığı, buna karşın devir arttıkça aşınmayla birlikte etki artmakta ve yüksek devirlerde aşınmaya katkı sağladığı görülmektedir. IE Dönmesinin insertin aşınması üzerinde AP ötelemesinden çok daha fazla etki yaptığı, özellikle devir sayısı arttıkça insert üzerindeki aşınmayı belirgin bir biçimde azalttığı, bu etkinin de aşınma bölgesinin genişlemesinden kaynaklandığı görülmektedir. Posterior tibial eğim açısı arttıkça, aynı devir için, maksimum temas basıncının hafifçe azaldığı da görülmektedir. Bu çalışma, fleksiyon sırasında yön değiştiren AP ötelemesinin ve açısal değişim yapan IE dönmesinin hem temas basıncı hem de aşınma üzerinde önemli etkisinin olduğunu göstermiştir. Literatürde yapılan daha önceki çalışmalardan farklı olarak devir arttıkça aşınmanın artmaya devam ettiği görülmüştür. Bu durum, yükleme ve fleksiyonla değişen AP ötelemesinin ve IE dönmesinin PE insert üzerindeki aşınma etkilerini şekillendirdiği savını güçlendirmektedir.

Özet (Çeviri)

The effect of posterior tibial slope on the maximum contact pressure and wear volume of polyethylene (PE) insert were not given special attention. In order to determine the effects of flexion angle, Anterior-Posterior (AP) translation, Internal-External (IE) rotation and Tibial slope on the max contact pressure and wear of PE insert of Total Knee Artroplasty (TKA) were investigated under loadings which were obtained in cadaver experiments by using Archard's wear law. This study uses not only loads obtained from cadaver experiments but also dynamic flexion starting from 0 to 90 degrees. Wear on knee implant PE insert was investigated using a 2.5 size 3 dimensional (3D) cruciate sacrificing total knee replacement model and Finite Element Method (FEM) under loadings and AP Translation data ranging from 0 to 90 flexion angles validated by cadaver experiments. Two types of analyses were done to measure the wear effect on knee implant PE insert. The first set of analyses included the flexion angles dynamically changing with the knee rotating from 0 to 90 angles according to the femur axis and the transient analyses for loadings changing with a certain angle and duration. It is seen that the contact pressure on the PE insert decreases as the cycle increases for both Flexion and Flexion+AP Translation. It is clear that as the cycle increases, the wear obtained for both cases increases. The loadings acting on the PE insert cannot create sufficient pressure due to the AP Translation effect at low speeds and have an effect to reduce the wear, while the effect increases with the wear as the cycle increases, and the AP Translation now contributes to the wear at high speeds. It is seen that the IE rotation has a much more effect on the wear of the insert than the AP translation, especially as the number of revolutions increases, it significantly reduces the wear on the insert, and this effect is due to the enlargement of the wear zone. It is also seen that as the posterior tibial slope angle increases, the maximum contact pressure values slightly decrease for the same cycle. This study indicated that AP Translation, which changes direction during flexion, and IE Rotation, which doing angular changes, had a significant effect on both contact pressure and wear. Unlike previous similar studies, it was seen that the amount of wear continues to increase as the cycle increases. This situation strengthens the argument that AP translation and IE rotation values that change with loading and flexion shape the wear effects on PE Insert.

Benzer Tezler

  1. 316L paslanmaz çelik üzerinde katodik ark FBB ve oxidasyon yöntemleriyle üretilen zirkonyum oksit kaplamaları özellikleri

    Properties of zirconium oxide coatings on 316-L stainless steels produced by cathodic arc PUD and oxidation techniques

    ERDEM ŞİRELİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA ÜRGEN

  2. Total diz artroplastisi sonrasında gelişen diz instabilitelerinde etkili risk faktörlerinin analizi ve tedavi algoritması

    Başlık çevirisi yok

    ATAKAN TELATAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    Ortopedi ve TravmatolojiSağlık Bilimleri Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF. YUSUF ÖZTÜRKMEN

  3. Unikompartmantal Diz Artroplastisi Uygulanan Hastalarda Klinik ve Radyolojik Sonuçların Değerlendirilmesi ve İmplant Pozisyonunun Klinik Sonuçlara Etkisi

    The Evaluation of Clinical And Radiological Results and The Impact Of Implant Positioning on These Clinical Results of Unicompartmental Knee Arthroplasty

    MUSTAFA ALADAĞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2012

    Ortopedi ve TravmatolojiAnkara Yıldırım Beyazıt Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DR. HAKAN ASLAN

  4. Aseptik gevşeme oluşumunda farklı insert hammaddelerinin etkilerinin hayvan modellemesinde deneysel olarak karşılaştırılması

    Comparing the effects of different insert raw materials on aseptic loosening formation in animal modelling

    CELALEDDİN BİLDİK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2016

    Ortopedi ve TravmatolojiSağlık Bakanlığı

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. BARANSEL SAYGI

  5. Fixed bearing ve mobile bearing inser kullanılan total diz prozeti uygulanmış hastaların klinik ve fonksiyonel sonuç açısından karşılaştırılması

    Comparison of the clinical and functional results of the patients who had undergone total knee replacement using fixed bearing and mobile bearing inserts

    KAMİL ÇAĞRI KÖSE

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2004

    Ortopedi ve TravmatolojiAnkara Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF. DR. İLKER ÇETİN