Geri Dön

Farklı doz algoritmalarıyla bilgisayarlı tomografi çekimlerinde operatör odasında radyasyon dozlarının ölçülmesi ve çalışanlarının dozlarının karşılaştırılması

Measurement of radiation doses in the operator's room and comparison of the doses of the employees in computed tomography shoots with different dose algorithms

  1. Tez No: 791118
  2. Yazar: MURAT YAĞMUR
  3. Danışmanlar: DOÇ. DR. AHMET YALÇIN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Bilgisayarlı tomografi, düşük doz, operatör odası, radyasyon maruziyeti, standart doz, yüksek doz, Computed tomography, high dose, low dose, operator room, radiation exposure, standard dose
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 74

Özet

Amaç: Yüksek doz, normal doz ve düşük doz algoritmaları kullanılarak yapılan BT ile görüntüleme esnasında operatör odasındaki radyasyon dozlarının anlık ölçülmesi ve aynı zamanda radyasyon çalışanlarının maruz kaldığı radyasyon dozlarının ölçülerek bu dozların karşılaştırılmasıdır. Materyal ve Metot: Bu çalışma Atatürk Üniversitesi Eğitim Ve Araştırma hastanesinde Ağustos 2022 -Eylül 2022 tarihleri arasındaki farklı doz algoritmaları kullanılarak 130 hasta üzerinde yapılan Toraks BT çekimleri esnasındaki farklı 3 noktada manuel doz ölçerle yapılan doz ölçüm verilerinin, cihazdan alınan doz verilerinin ve şahsi dozimetre verilerinin karşılaştırılmasıyla gerçekleşti. Çalışmada BT cihazı, manuel doz ölçer ve şahsi dozimetre kullanıldı. Alınan ölçümler sonucu istatistiksel analiz yapılarak sonuca ulaşıldı. Bulgular: Çalışma popülasyonunun yaş ortalaması 57,6 ± 19,3 dür ve 130 hastanın 73'ü erkektir. (%55,7). Üç grupta operatör odası penceresi önü, kapı açılışı ve operatör odası içinde ölçülen ortam radyasyon dozu, yüksek doz grubunda istatistiksel olarak anlamlı derecede daha yüksek radyasyon dozları gözlemlenirken, düşük doz ve standart doz grupları arasında anlamlı bir fark görülmedi. Son aşamada personel dozimetrelerinin verileri toplandı. Kişisel dozimetre verileri incelendiğinde toplanan verilerin gruplar arasında anlamlı bir fark göstermediği görüldü. Sonuç: Çalışmamızda elde ettiğimiz bulgular ışığında, yüksek doz algoritması ile yapılan görüntüleme esnasında operatör odasında yapılan ölçümlerde standart ve düşük doz algoritmalı görüntüleme esnasındaki ölçümlere ve incelemelere göre daha yüksek radyasyon bulunduğunu ve radyasyon varlığının daha uzun süre devam ettiğin sonucuna ulaştık.

Özet (Çeviri)

Aim: Our aim is to assess dose of ambient radiation in the operator room during CT imaging with high-dose, normal-dose and low-dose algorithms, as well as the measurement and comparison of radiation doses of technicians. Material and Method This study was conducted on 130 patients presented in CT unit of Ataturk University Research Hospital between August 2022 and September 2023. All radiation dose measurements were performed with manual receiver in three separate locations and in different time intervals during the Thorax CT imaging which performed using different dose algorithms. Radiation doses measured at these locations and time intervals then compared to personal dosimeters for three different dose algorithms. Results: The mean age of the study population was 57.6 ± 19.3 years, and 73 of the 130 patients were male. (55.7%). The ambient radiation dose measured in front of the operator room window, door opening and inside the operator room in the three groups showed that statistically significantly higher radiation doses were observed in the high dose group whereas there was no significant difference between the low dose and standard dose groups. Comparison of radiation dose measured by personnel dosimeter revealed no significant differences between the groups. Conclusion: : In our study we have found that the measurements performed in the operator room during imaging with the high-dose algorithm resulted higher radiations doses, compared to the measurements during standard and low-dose algorithm. We have also found that the presence of radiation lasted longer in examinations with high dose algorithm.

Benzer Tezler

  1. Yoğunluk ayarlı prostat radyoterapi planlarının farklı tedavi planlama algoritmaları ile dozimetrik karşılaştırılması

    Dosimetric comparison of intensity modulated prostate radiotherapy plans with different treatment planning algorithms

    AHMET ŞAHİN

    Doktora

    Türkçe

    Türkçe

    2022

    Fizik ve Fizik MühendisliğiSelçuk Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. NİHAL BÜYÜKÇİZMECİ

  2. 3 farklı algoritmada hesaplanan akciğer SBRT planlarının dozimetrik karşılaştırılması

    Dosimetric comparision of lung SBRT plans calculated in 3 different algoritms

    İSMAİL ANATÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Sağlık EğitimiAnkara Yıldırım Beyazıt Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. GÜVEN ÇANKAYA

  3. Farklı platformlarda hazırlanan SRS tedavi planlarının dozimetrik doğruluğunun araştırılması

    Investigation of dosimetric accuracy of SRS treatment plans in different platforms

    GÜLHAN ÇAVDAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Onkolojiİstanbul Medipol Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    DOÇ. DR. HİLAL ACAR DEMİR

  4. Tedavi planlama sistemlerindeki inhomojenite düzeltme faktörlerinin akciğer dokusundaki doz dağılımına olan etkilerinin dozimetrik olarak incelenmesi

    The dosimetric evaluation of the effects of inhomogeneity correction factors in the treatment planning system on dose distribution in the lung tissue

    NÜKHET KÜRKÇÜ

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    OnkolojiTrakya Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. ZAFER KOÇAK

  5. İnhomojen dokularda analitik anizotropik ve pencil beam convolution algoritmalarıyla hesaplanan dozların karşılaştırılması

    Comparison of doses calculated by anisotropic analytical algorithm and pencil beam convolution in the inhomogeneous tissues

    ESRA KÜÇÜKMORKOÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    OnkolojiAcıbadem Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. MELAHAT GARİPAĞAOĞLU