Geri Dön

Tavşan tibiasına yerleştirilen implanta onlay greft materyali olarak uygulanan tetrakalsiyum fosfatın (Grandus b-one enjekte edilebilir biyolojik onarım implantının) osseointegrasyona etkilerininhistomorfometrik değerlendirilmesi

Histomorphometric evaluation of the effects of tetracalcium phosphate (Grandus b-one injectable biological repair implant) on osseointegration, applied as onlay graft material to implant placed in rabbits' tibias

  1. Tez No: 803755
  2. Yazar: KHANIM RZAYEVA
  3. Danışmanlar: PROF. DR. HASAN YELER
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Otojen greftleme, kemik greftler, tetrakalsiyum fosfat, dental implant, osseointegrasyon, Autogenous grafting, bone grafts, tetracalcium phosphate, dental implant, osseointegration
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Sivas Cumhuriyet Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 107

Özet

Çalışmamızdaki amaç, tavşan tibiasında defektli alana yerleştirilen implantın etrafına uygulanan tetrakalsiyum fosfat greftin implant stabilitesi üzerine etkilerinin histomorfometrik incelenmesidir. Çalışmamızda 18 adet Yeni Zelenda Beyaz Tavşanı kullanılmıştır. Tavşanlar kontrol, birinci deney ve ikinci deney grubu olarak 3 gruba ayrılmıştır. Gruplara ayrılan tavşanların her iki tibiasına da aynı işlemler uygulanmıştır. Deney gruplarındakı tavşanların tibialarında bilateral 5 mm defektler oluşturulmuştur. Kontrol gurubundaki tavşanlara (6 tavşan- 12 tibia) 3.0 x 8.5 mm'lik dental implantlar yerleştirildi. Birinci Deney Grubunda (6 tavşan- 12 tibia) 5 mm'lik defekte yerleştirilen 3.0 x 8.5 mm'lik implantın çevresine tetrakalsiyum fosfat uygulandı. İkinci Deney Grubunda (6 tavşan-12 tibia) ise oluşturulan 5 mm'lik defekte yerleştirilen 3.0 x 8.5 mm'lik implantların çevresine defekt bölgesinden çıkarılan otojen kemik grefti çıkarıldıktan sonra kemik öğütücüsünde öğütülerek tekrar tetrakalsiyum fosfatla karıştırılarak defekt bölgesine yerleştirildi. İmplantlar yerleştirildikten hemen sonra Ostell™ ISQ cihazı kullanılarak RFA gerçekleştirildi. İmplantın yerleştirilmesinden 90 gün sonra tavşanlar sakrifiye edilmeden vii önce ISQ değerleri ikinci kez tekrar ölçülmüştür. Daha sonra ölçüm hatalarını azaltmak için ortalamalar hesaplanmıştır. Deney 90 gün sürdükten sonra sonlandırılmıştır. Yapılan çalışmanın histomorfometrik analiz değerlendirilmesi sonucunda gruplara ilişkin Kemik-implant teması (BIC) oranı karşılaştırıldığında gruplar arası farklılık önemsiz bulunmuştur. Gruplar arasında RFA'daki varyasyonlar birinci ve ikinci zaman noktası arasındaki stabilite değerlerine bağlı olarak önemli ölçüde artış göstermiştir. Çalışmamızda kullandığımız TTCP bazlı Grandus® B-One materyalinin ticari olarak son yıllarda kullanıma sunulmuş olan bir ürün olmasında dolayı, literatürde sunulmuş bilimsel çalışmalar kısıtlıdır. Bu nedenle TTCP primer ve sekonder stabillite yönünden karşılaştırıldığı çalışmalar yetersizdir. Daha geniş çaplı bir hayvan çalışması ve daha fazla alt gruplarla yapılan çalışmalarda deneyin anlamlı sonuçlarının artacağı düşünmekteyiz.

Özet (Çeviri)

The aim of our study is to examine the effects of tetracalcium phosphate graft applied around the implant placed in the defected area of the rabbit tibia on the stability of the implant histomorphometrically. In our study, 18 New Zealand white rabbits were used. Rabbits were divided into 3 groups as control group, first experimental group and second experimental group. The same procedures were applied to both tibiae of the rabbits divided into groups. Bilateral 5 mm defects were created in the tibias of the rabbits in the experimental groups. 3.0 x 8.5 mm dental implants were placed in the rabbits in the control group (6 rabbits - 12 tibia). In the first experimental group (6 rabbits - 12 tibia), tetracalcium phosphate was applied around the 3.0 x 8.5 mm implant placed in the 5 mm defect. In the second experimental group (6 rabbits - 12 tibia), the autogenous bone graft extracted from the defect area was removed around the 3.0 x 8.5 mm implants placed in the 5 mm defect created, then it was ground in a bone grinder, mixed with tetracalcium phosphate, and placed in the defect area. ix RFA was performed using the Osstell™ ISQ device immediately after the implants were placed. ISQ values were re-measured a second time before the rabbits were sacrificed 90 days after implant placement. Then the averages were calculated to reduce the measurement errors. The experiment was terminated after 90 days. As a result of the histomorphometric analysis of the study, when the bone-implant contact (BIC) ratios of the groups were compared, it was seen that the difference between the groups was insignificant. Variations in RFA between groups increased significantly depending on the stability values between the first and second time point. Since the TTCP-based Grandus® B-One material we used in our study is a product that has been commercially available in recent years, scientific studies presented in the literature are limited. Therefore, studies comparing TTCP in terms of primary and secondary stability are insufficient. We think that more meaningful results will be obtained in larger animal studies and studies with more subgroups.

Benzer Tezler

  1. Allogreftle beraber lokal olarak uygulanan rifamisin veya sistemik olarak uygulanan çörek otu yağının koronal açıklığı olan dental implantların osseointegrasyonu üzerine etkilerinin deneysel olarak incelenmesi

    An experimental investigation on the effects of locally applied rifamycin or systemically ni̇gella sati̇va oil with allograft for osseointegration in surgically created bone defects around dental implants

    OĞUZHAN MEHMET ELMALI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2016

    Diş HekimliğiCumhuriyet Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. HASAN YELER

  2. Isısal nekroz yardımıyla tavşan tibiasına yerleştirilen dental implantların sökümü

    Başlık çevirisi yok

    MEHMET MERTCAN GENÇ

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. DR. MUSTAFA RAMAZANOĞLU

  3. Dental implantların 2 farklı teknik olan piezocerrahi osteotomi ve novel osseodensifikasyon yöntemiyle yerleştirildikten sonra implantların osseointegrasyonu üzerine etkilerinin değerlendirilmesi: Tavşan tibiasında deneysel çalışma

    Evaluation of the effects of dental implants on the osseointegration of implants after placing with 2 different technique of piezosurgery osteotomy and novel osseodensification method: Experimental study in rabbit tibia

    MURAT ARSLAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiSivas Cumhuriyet Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ TURGAY PEYAMİ HOCAOĞLU

  4. Sistemik ssrı kullanımının dental implant osseoentegrasyonuna etkisinin rezonans frekans analizi, histolojik ve immünohistokimyasal incelenmesi: Tavşan tibiasında deneysel çalışma

    Resonance frequency analysis, histological and immunohistochemical investigation of the effect of systemic ssri use on dental implant osseointegration: Experimental study in rabbit tibia

    OZAN ERGEN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiDicle Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. DR. BEYZA KAYA

  5. İmplant üstü sabit protezlerde, farklı kuron sökümü işlemlerinin implantın osseointegrasyonu üzerine etkilerinin incelenmesi

    Investigation of the effect of different crown removing procedures on the osseointegration of dental implants in implant retained fixed prosthesis

    YASEMEN ÜNAL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2015

    Diş HekimliğiCumhuriyet Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. HAKAN AKIN