Geri Dön

Farklı materyaller ile restore edilmiş farklı bağlantı sistemlerine sahip konometrik tek kron restorasyonlarda stres dağılımının 3 boyutlu sonlu elemanlar analizi ile değerlendirilmesi

Evaluation of stress distribution in conometric single crownrestorations with different connection systems restored with different materials using3d finite element analysis

  1. Tez No: 852462
  2. Yazar: SİNEM VURAL
  3. Danışmanlar: DOÇ. DR. BUKET EVREN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: İmplant, konometrik, sonlu elemanlar analizi, Implant, conometric, finite element analysis
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: 111

Özet

Amaç: Bu çalışmanın amacı fonksiyonel yükler altında konometrik bağlantı sistemine sahip implant üstü konometrik tek kuron restorasyonlarında monolitik translüsent zirkonya seramik (TZI) ve monolitik lityum disilikat cam seramik (LDS) restoratif materyallerinin implant komponentlerindeki ve çevre kemik dokulardaki stres dağılımlarına olan etkisinin üç boyutlu sonlu elemanlar analizi ile değerlendirilmesidir. Gereç ve Yöntem: Maksiller sağ ikinci premolar bölgesine yerleştirilen farklı bağlantı sistemlerine sahip üç implant (AstraTech, Ankylos, Xive Dentsply Implants, İsveç) üzerine uygulanan konometrik abutment ve kep (Conometeric abutment EV ve Conometeric Final Cap, Dentsply Implants, İsveç) ile iki farklı tam seramik materyalinden üretilmiş restorasyonlarda; vertikal ve oblik yükler aklında implant komponentlerinde ve implantı çevreleyen kortikal ve spongiyoz kemik dokusunda ve kuronlarda oluşan stres dağılımları üç boyutlu sonlu elemanlar stres analizi ile değerlendirildi. İstatistiksel değerlendirmede bağımsız örneklem t ve tek yönlü Anova testleri kullanıldı. Bulgular: Belirlenen kritik lokasyonlarda en yüksek stres değerleri LDS materyali için internal düz bağlantıda implant abutment ara yüzeyinde 565,44 MPa olarak oblik 100 N aşamasında meydana gelmiştir. Vidaya ait en yüksek stres değeri bulguları ise morse taper bağlantıda vida geçiş bölgesinde 518, 96 MPa'dır. Kemiğe ait en yüksek değerler ise internal düz bağlantıya sahip grup için oblik 100N kuvvet simülasyonunda kortikal maksimum 65,52/kortikal minimum -66,28 MPa'dır. Kep yüzeyindeki en yüksek stres internal düz bağlantıya sahip grupta oblik yükleme anında LDS materyalinde gözlenmiştir. Sonuç: İnternal düz bağlantıya sahip grupta kemik yüzeyindeki stres değerlerinin daha yüksek olması ileri dönem kemik yıkımı ihtimalini artması açısından dezavantajıdır. Konik bağlantıya sahip grupta herhangi bir lokasyonda çok yüksek değerler gözlenmemesi ileri dönem başarısı açısından daha umut vaad edicidir.

Özet (Çeviri)

Objective: The aim of the study is to compare the effect of monolithic translucent zirconia ceramic (TZI) and lithium disilicate glass ceramic (LDS) restorative materials on stress distributions in implant components and surrounding bone tissues in implant-supported conometric single crown restorations with a tapered connection system by using 3D finite element analysis. Material and Method: Restorations produced with two different all-ceramic materials using conometric abutment and cap (Conometeric abutment EV, Conometeric Final Cap, Dentsply Implants, Sweden) on three different implant systems (AstraTech, Ankyloss, Xive, Dentsply Implants, Sweden) were placed in maxillary right second premolar region. 3D finite element analysis was used to examine the distribution of stress in the implant components, in cortical and cancellous bone tissue surrounding implant, and on crowns under vertical and oblique loading. Independent sample t and one-way ANOVA tests were used for the statistical evaluation. Results: In oblique simulation, maximum stress distribution in implant and its components occurred at internal flat connection implant abutment contact (565,44). MPa. Screw's peak stress values were determined to be 518, 96 in transition zone for morse taper conneciton. Cortical maximum and minimum principal stress values were 65,52 MPa/-66,28 MPa, for internal connection. LDS exhibited greatest surface stress on cap for internal connection. Conclusion: The fact that the stress values on the bone surface are higher in the third group with internal flat connection is a disadvantage in terms of increasing the possibility of bone destruction. High values are not observed in any location in conical connection is more promising terms of future success.

Benzer Tezler

  1. Farklı materyaller ile restore edilmiş farklı bağlantı açılarına sahip implant-dayanak sistemlerinin mikro-aralıklarının çiğneme simülatörü ile yaşlandırma sonrası karşılaştırılması

    Micro-GAP comparison of implant-abutment systems with different connection angles restored with different materials after aging with chewing simulator

    TUĞÇE ÇETİN BİLGİÇ

    Doktora

    Türkçe

    Türkçe

    2023

    Diş HekimliğiMarmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. YILMAZ UMUT ASLAN

  2. Farklı adeziv sistemlerin bağlanma dayanımlarının, mikrosızıntılarının ve rezin-dentin bağlanma arayüzeylerinin pulpa odası duvarında değerlendirilmesi

    Evaluation of bond strength, microleakage and resin-dentin interfaces of different adhesive systems on the pulp chamber walls

    BORA ÖZTÜRK

    Doktora

    Türkçe

    Türkçe

    2002

    Diş HekimliğiSelçuk Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF.DR. FÜSUN ÖZER

  3. Farklı post materyalleri ile restore edilmiş apikal lezyonlu dişlerin dayanak olduğu protetik restorasyonların çiğneme kuvveti altında ortaya çıkan yapısal gerilme dağılımlarının sonlu elemanlar analizi ile incelenmesi

    Investigation of structural stress distributions under chewing force of prosthetic restorations on teeth with apical lesions restored with different post materials by finite element analysis

    AYŞE TÜRKYÖN KARACAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiAkdeniz Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ÖMER KIRMALI

  4. Süt molar dişlerde farklı matriks sistemleri ile restore edilen sınıf 2 kompomer ve kompozit rezin restorasyonların arayüz kontakt noktası sıkılığı ve marjinal taşkınlık açısından in-vitro değerlendirilmesi

    In-vitro evaluation of class 2 compomer and composite resin restorations restored with different matrix systems on primary molar teeth in terms of proximal contact tightness and marginal overhang

    GAMZE NAZLI YANAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiGazi Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    PROF. DR. CENGİZ HALUK BODUR

  5. Open sandwıch tekniği ile farklı restoratif malzemeler kullanılarak restore edilmiş dişlerdeki mikrosızıntı değerlerinin in-vitro koşullarda incelenmesi

    In-vitro evaluation of microleakage in open sandwich technique restored with different restorative materials.

    ANIL ÇETİN

    Doktora

    Türkçe

    Türkçe

    2008

    Diş HekimliğiMarmara Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF. DR. F. BÜLENT TOPBAŞI