Ortogonal radyasyon alanları içeren baş-boyun tümörlerinin, asimetrik kolime edilmiş CO-60 ve 4MV (X) ışınları ile tedavisinde set-up hatalarının birleşim bölgesine etkisi

The Effect of set-up mistakes at the adjacent field junctions in the treatment of head and neck tumors with orthogonal radiation fields at C=-60 which collimated asymmetrically 4 MV X-ray beams

  1. Tez No: 86443
  2. Yazar: HALİL KÜÇÜCÜK
  3. Danışmanlar: DOÇ. DR. HATİCE BİLGE
  4. Tez Türü: Yüksek Lisans
  5. Konular: Onkoloji, Radyoloji ve Nükleer Tıp, Oncology, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Fotokemoterapi, Kafa ve boyun neoplazmları, Radyoterapi, Photochemotherapy, Head and neck neoplasms, Radiotherapy
  7. Yıl: 1999
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Temel Onkoloji Ana Bilim Dalı
  12. Bilim Dalı: Tıbbi Radyofizik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Nazofarenks, tonsil, dilkökü, ağız tabanı gibi baş boyun kanserlerinin radyoterapisinde ortogonal radyasyon alanları kullanılmaktadır. Ortogonal radyasyon alanlarını ışınlarken farklı teknikler kullamlmaktadır.Co-60 cihazında kullanılan yarı blok tekniği ve lineer hızlandırıcılarda kullanılan asimetrik kolimatör tekniği bu tekniklerden ikisidir. Bu iki tekniktede amaç diğer tekniklerde de olduğu gibi alan birleşim bölgesinde üst üste binme(overlap) ve aralık ka!ması(gap)durumunda oluşacak sıcak ve soğuk noktaları önleyip homojen doz dağılımı elde etmektir. Bu çalışmada, Co-60 cihazıyla yapılan ışınlamalarda yarı blok, 4MV lineer hızlandırıcı ile yapılan ışınlamalarda cihazın asimetrik kolimatörü kullanılmıştır.Her iki cihazla yapılan ışınlamarda birleşim bölgesinde alanlar arasındaki aralık (gap) ve üst üste binme(overlap) durumunda d=1, 2, 3 ve 4.5 cm derinliklerde doz homojenitesi, katı-su fantomu kullanılarak film dozimetrisi yöntemiyle belirlenmiştir. Her iki cihazla yapılan ışınlamalarda elde edilen doz profilleri karşılaştırıldığında alan kenarları arasında oluşan 2 mm'lik aralığın her iki cihaz için doz homojenitesini bozmadığı görülmüştür. Birleşim bölgesindeki alan kenarları arasındaki aralık arttıkça doz homojenitesi bozulmuştur. Alanların 2 mm üst üste binmesi durumunda her iki aletle yapılan ışınlamalarda doz farklılığı %10' un biraz üzerindedir.4, 6, 8 ve 10 mm üst üste binmelerde 4MV lineer hızlandırıcının asimetrik kolimatörüyle yapılan ışınlamalarda elde edilen farklılık Co-60 cihazı ile yapılan ışınlamalarda elde edilen doz farklılığına göre daha fazla olduğu saptanmıştır. 48

Özet (Çeviri)

SUMMARY Orthogonal irradiation fields are used in radiotherapy of head and neck carcinoma as nasopharenx, base of tonque, tonsilla, oral cavity carcinoma. There are different techniques for irradiation of orthogonal fields. Half block technique for Co-60 machines and asymmetric collimator technique for linear accelerators are two of these. In these techniques the aim is to avoid the potential problems of hot spots and cold spots that has been because of overlap or gap at the adjacent fields and to obtain homogenous accurate dose distributions. In this study, half block in Co-60 machine and asymmetric collimator in 4 MV linear accelerator were used. Dose homogenity at d= 1, 2, 3, 4.5 cm deep in the situation of overlap and gap between the adjacent fields with half block technique and asymmetric collimator technique were compared. Film dosimetry tecnique was used in Co-60 machine and 4 MV linear accelerator. The solid-water phantom were used for film dosimetry. Dose profiles obtained from both irradiation techniques were compared for each machine and it was seen that 2 mm gap between the two adjacent fields was not changed the dose homogenity. When the gap between the adjacent fields was increased than the dose homogenity was changed. Two milimeter overlap between the adjacent fields changed the dose homogenity more than % 10 in each machine. At 4, 6, 8, 10 mm overlap the dose difference delivered from the irradiation with 4 MV linear accelerator machine was more than the difference delivered with Co-60 machine. 49

Benzer Tezler

  1. Radiation-induced effects on N-type metal oxide semiconductor field effect transistor devices: Modeling, simulation and optimization

    N-tipi metal oksit yarı iletken alan etkili tranzistorlar üzerinde radyasyon kaynaklı etkiler: Modelleme, simülasyon ve optimizasyon

    SADIK İLİK

    Yüksek Lisans

    İngilizce

    İngilizce

    2019

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektro-Optik Sistem Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MUSTAFA BERKE YELTEN

  2. Pulsar magnetospheres and intra - pulse variability by plasmoid formation

    Atarca manyetosferleri ve plazmoid oluşumu kaynaklı atım - arası değişkenliği

    İBRAHİM CEYHUN ANDAÇ

    Doktora

    İngilizce

    İngilizce

    2024

    Fizik ve Fizik Mühendisliğiİstanbul Teknik Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    PROF. DR. KAZIM YAVUZ EKŞİ

  3. Baş ve boyun radyoterapisinde konvansiyonel ve asimetrik ortogonal planlamalarda larinks dozlarının karşılaştırılması.

    Comparsion doses to the larynx conventional and asymmetric orthogonal planning in head and neck radiotherapy.

    ERHAN DİŞÇİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2008

    Onkolojiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    DOÇ. DR. İSMAİL ÖZBAY

  4. Improvement of electrical and photocatalytic properties of boron-doped ZnO nanorods and synthesis design optimization by taguchi approach

    Bor-katkılı ZnO nanorodlarinin elektriksel ve fotokatalitik özelliklerinin geliştirilmesi̇ ve taguchi yaklaşımı ile sentez tasarımının optimizasyonu

    ERAY TABAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Biyomühendislikİstanbul Teknik Üniversitesi

    Nanobilim ve Nanomühendislik Ana Bilim Dalı

    DOÇ. DR. BİRGÜL BENLİ

  5. Bitişik alan IMRT planlamasında iki farklı kolimatör ( x ve y ) yönünün birleşim bölgesindeki doz dağılımına etkisinin araştırılması

    The investigation of the effects of two different collimator direction (X and Y) on conjunction region dose distribution in adjacent fields IMRT planning.

    AYDIN ÇAKIR

    Doktora

    Türkçe

    Türkçe

    2010

    Onkolojiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE