Geri Dön

Farklı CAD/CAM materyallerin renk stabiliteleri ve yüzey özelliklerinin değerlendirilmesi

Evaluation of color stability and surface properties of different CAD/CAM materials

  1. Tez No: 908658
  2. Yazar: AYÇA TOPALOĞLU
  3. Danışmanlar: DOÇ. DR. HAKKI CENKER KÜÇÜKEŞMEN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: CAD/CAM, Rezin seramik, Lityum disilikat seramik, Renk stabilitesi, Yüzey pürüzlülüğü, Mikrosertlik, Temas açısı, CAD/CAM, Resin ceramic, Lithium disilicate ceramic, Color stability, Surface roughness, Microhardness, Contact angle
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Süleyman Demirel Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Gelişen CAD/CAM (Bilgisayar Destekli Tasarım/Bilgisayar Destekli Üretim) teknolojilerinin diş hekimliği alanında kullanımları arttıkça yeni nesil materyaller geliştirilmeye başlanmıştır. Bu geliştirilen materyallerin hedeflerinden birisi de tek seans hasta başı restorasyon üretimini sağlayabilmektir. Bu çalışmanın amacı CAD/CAM sistemlerinde kullanım için geliştirilmiş, kazımadan sonra fırınlama işlemi gerektirmeyen, 3 farklı rezin matriks seramik ve 1 tam kristalize lityum disilikat seramiğin farklı renklendirici solüsyonlarda bekletilmesiyle oluşan renk, yüzey pürüzlülüğü, yüzey sertliği ve temas açısı değerlerinin değişiminin incelenmesidir. Vita Enamic (VITA Zahnfabrik, BadSäckingen, Almanya), Cerasmart270 (GC, Tokyo, Japonya), Shofu Block HC (Shofu, Kyoto, Japonya) ve GC Initial LiSi (GC, Tokyo, Japonya) bloklarından 1,5 mm kalınlığında toplam 120 örnek elde edilmiştir (n=30). Örneklere kendilerine özel mekanik cila setleri kullanılarak polisaj yapılmış ve her grup distile su, kahve ve şarapta bekletilmek üzere 3 alt gruba ayrılmıştır (n=10). Örnekler 30 gün boyunca 37 derece etüvde bekletilmiştir. Başlangıç ve 7, 14, 30. gün renk değerleri D65 ışık kaynağına sahip renk ölçüm kutusu içinde beyaz zemin üzerinde spektrofotometre ile (Vita EasyShade V, Vita Zahnfabrik, Almanya) ölçülmüş ve renk farkı CIEDE2000 formülü kullanılarak hesaplanmıştır. Başlangıç ve 30. gün yüzey pürüzlülüğü ve sertlik değerleri ölçülmüş ayrıca her gruptan rastgele 3 örnek belirlenerek başlangıç ve 30. gün temas açısı değerleri kaydedilmiştir. Veriler, IBM SPSS v23.0 programı ile analiz edilmiştir. Verilerin normal dağılıma uygunluğu Shapiro-Wilk testi ile incelenip, normal dağılıma sahip parametrelerin gruplar arasındaki farkları tek yönlü ANOVA testi ile değerlendirilmiştir. Materyal ve solüsyonlara göre ortalama değerlerin karşılaştırılmasında iki yönlü ANOVA testi, çoklu karşılaştırmalar için Tukey testi uygulanmıştır. Tekrarlayan zamanlarda ölçülen parametrelerin gruplar içindeki değişimi ise tekrarlayan ölçümlerde ANOVA testi ve post hoc testi olarak Tukey testi ile belirlenmiştir. p<0.05 istatistiksel olarak anlamlı kabul edilmiştir. 30 günün sonunda en çok renklenme SH-Şarap grubunda, en az renklenme LiSi- Distile su grubunda görülmüştür. Materyal türü, solüsyon çeşidi ve zamanın renklenme üzerinde anlamlı etkisi olduğu görülmüştür (p<0.05). LiSi- Şarap ve Kahve grupları 30 günün sonunda en yüksek pürüzlülükte bulunmuştur. Yüzey sertliği en az değişen grup LiSi-Distile su grubu olurken en fazla azalan grup VE-Şarap grubu olmuştur. Temas açısı değerleri incelendiğinde en çok değişim LiSi-Şarap grubunda görülmüştür. Sonuç olarak, bu çalışmanın koşulları dahilinde lityum disilikat seramiğin renk stabilitesinin rezin matriks seramiklerden daha iyi olduğu, yüzey sertliği, pürüzlülük ve temas açısı üzerinde solüsyon çeşidi, zaman ve materyal türünün etkili olduğu görülmüştür.

Özet (Çeviri)

As the use of developing CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) technologies in dentistry increases, new generation materials have begun to be developed. One of the goals of these developed materials is to provide single-visit chairside restoration production. The aim of this study was to investigate changes in color, surface roughness, surface hardness, and contact angle of three different resin matrix ceramics and one fully crystallized lithium disilicate ceramic, all designed for use in CAD/CAM systems without the need for post-milling firing. A total of 120 samples, each 1,5 mm thick, were obtained from Vita Enamic (VITA Zahnfabrik, Bad Säckingen, Germany), Cerasmart270 (GC, Tokyo, Japan), Shofu Block HC (Shofu, Kyoto, Japan), and GC Initial LiSi (GC, Tokyo, Japan) blocks (n=30 per material). The samples were polished with special mechanical polishing sets, then divided into three subgroups to be immersed in either distilled water, coffee and wine (n=10 per subgroup). The samples were stored in an oven at 37°C for 30 days. Color measurements were taken initially and at days 7, 14, and 30 using a spectrophotometer (Vita EasyShade V, Vita Zahnfabrik, Germany) on a white background in a D65 light source color measurement box. The color difference was calculated using the CIEDE2000 formula. Surface roughness and hardness values were measured initially and after 30 days, and three random samples from each group were selected to record initial and 30-day contact angle values. Data were analyzed with IBM SPSS v23.0. Normal distribution conformity was assessed with the Shapiro-Wilk test, and group differences for normally distributed parameters were evaluated with a one-way ANOVA test. Mean comparisons across materials and solutions were done with a two-way ANOVA, and multiple comparisons were assessed with Tukey's test. Changes over time within each group were determined using repeated-measures ANOVA, with Tukey's test for post hoc analysis. A significance level of p<0.05 was used. At the end of 30 days, the highest discoloration was seen in the SH-Wine group, while the LiSi-Distilled water group showed the lowest discoloration. Material type, solution type, and time were found to have a significant effect on discoloration (p<0.05). The highest surface roughness was observed in the LiSi-wine and coffee groups after 30 days. The LiSi-Distilled water group showed the least decrease in surface hardness, while the VE-Wine group showed the most significant decrease. When examining contact angle values, the highest change was observed in the LiSi-Wine group. In conclusion, lithium disilicate ceramics demonstrated better color stability than resin matrix ceramics under the conditions of this study, and solution type, time, and material type significantly impacted surface hardness, roughness and contact angle.

Benzer Tezler

  1. Evaluation of mechanical and optical properties of different CAD-CAM materials after gastric acid exposure

    Farklı CAD-CAM materyallerinin gastrik aside maruz bırakılmasının ardından mekanik ve optik özelliklerinin değerlendirilmesi

    ELİFNAZ ÖZEN

    Doktora

    İngilizce

    İngilizce

    2021

    Diş HekimliğiYeditepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. PINAR KURSOĞLU

  2. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  3. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    ÜrolojiGazi Üniversitesi

    Üroloji Ana Bilim Dalı

  4. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Besin Hijyeni ve Teknolojisiİstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    DOÇ. DR. TÜRKAN KUTLUAY