Geri Dön

Yüksek sıcaklık sonrası suyla yeniden kürlemenin hibrit lif takviyeli betonun eğilme davranışı ve mekanik özellikleri üzerine etkisi

Effect of water re-curing after high temperature on flexural behavior and mechanical properties of hybrid fiber reinforced concrete

  1. Tez No: 920549
  2. Yazar: YUNUS URTEKİN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ ZİNNUR ÇELİK
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Yapı Malzemeleri Bilim Dalı
  13. Sayfa Sayısı: 94

Özet

Amaç: Bu araştırma, farklı tür ve oranlarda çelik, bazalt ve polipropilen lif içeren beton karışımların oda sıcaklığında, yüksek sıcaklık ve su ile yeniden kürleme sonrası mekanik özelliklerindeki değişimi belirlemek amacıyla yapılmıştır. Yöntem: Lifsiz beton (kontrol) ve dört farklı lif kompozisyonu üzerinde yüksek sıcaklık ve yeniden su kürü uygulanmış; ilk karışımda sadece çelik lifler kullanılmış, diğer iki karışımda ise çelik lifler yerine %25 ve %50 oranlarında bazalt lifler ikame edilmiştir. Ayrıca beşinci karışımda bazalt lif, çelik ve bazalt hibrit lif takviyeli karışımla karşılaştırma yapmak için polipropilen lif ile değiştirilmiştir. Beton numunelerinde kullanılan lif hacmi, tüm karışımlarda beton hacminin %0.80'i olarak sabitlenmiştir. Karışımlardaki çimento içeriği 450 kg/m3 ve su/çimento oranı 0.42 olarak belirlenmiştir. Beton karışımlarında lif kullanımından dolayı azalan çökme değerlerini iyileştirmek amacıyla süperakışkanlaştırıcı eklenmiştir. Çalışmada hazırlanan karışımlar, 400 °C, 600 °C ve 800 °C sıcaklıklara maruz bırakıldı. Yüksek sıcaklık sonrası numunelerin yarısı mekanik testlere tabi tutulurken diğer yarısı 28 gün boyunca suyla yeniden kürlemeye bırakılmıştır. Bu kapsamda, hazırlanan lifli ve lifsiz karışımlar oda sıcaklığında, yüksek sıcaklık ve suyla yeniden kürleme sonrası ultrasonik atılımlı dalga hızı (UADH), basınç dayanımı, eğilme dayanımı, eğilme davranışı, yük taşıma ve tokluk değerlerini belirlemek için teste tabi tutulmuşlardır. Bulgular ve sonuç: Çalışmanın sonucunda; ortam sıcaklığında, lif kullanılan karışımların UADH değerleri referans karışımına kıyasla hafifçe düştüğü gözlemlendi. Oda sıcaklığında %0,40 bazalt elyaf içeriğine sahip karışım hariç tüm serilerde basınç dayanımında artış elde edilmiştir. Bu durum bazalt elyaf içeriğinin artırılmasının basınç dayanımı üzerindeki olumsuz etkisini göstermiştir. Lif kullanımı özellikle eğilme dayanımı, yük taşıma kapasitesi ve tokluk açısından önemli iyileştirmelere neden olmuştur. Numuneler yüksek sıcaklığa maruz kaldıkça, özellikle 600°C ve üzeri sıcaklıklarda mekanik özelliklerinde dikkate değer düşüşler gözlenmiştir. Suyla tekrar kürleme, ısıtmadan sonra termal olarak hasar görmüş lifli ve lifsiz betonların performansının geri kazanılmasında önemli bir etkiye sahip olduğu tespit edilmiştir. Bu geri kazanım özellikle 600°C ve üzeri sıcaklıklarda daha belirgin olduğu görülmüştür. Eğilme dayanımı açısından, 600°C'ye maruz bırakıldıktan sonra yeniden kürleme, referans numune başlangıç dayanımının %58.32'sine, %0.80 oranında çelik lif kullanılan karışımın ise %71.86'sına ulaşmıştır. Bu değerler, tekrar kürlenmeden önce sırasıyla %30.11 ve %41.08 idi. 800 °C'den sonra suyla tekrar kürleme, tüm karışımların geri kazanım oranlarını birbirine yaklaştırmıştır.

Özet (Çeviri)

Purpose: This research was carried out to determine the changes in mechanical properties of concrete mixtures containing different types and proportions of steel, basalt and polypropylene fibers after re-curing at room temperature, high temperature and with water. Method: High temperature and water re-curing were applied on non-fiber concrete (control) and four different fiber compositions; only steel fibers were used in the first mixture, and basalt fibers were substituted in the other two mixtures at 25% and 50% ratios instead of steel fibers. In addition, basalt fiber was replaced with polypropylene fiber in the fifth mixture to make a comparison with the steel and basalt hybrid fiber reinforced mixture. The fiber volume used in the concrete samples was fixed as 0.80% of the concrete volume in all mixtures. The cement content in the mixtures was determined as 450 kg/m3 and the water/cement ratio as 0.42. Superplasticizer was added to improve the slump values decreased due to the use of fibers in the concrete mixtures. The mixtures prepared in the study were exposed to temperatures of 400 °C, 600 °C and 800 °C. After the high temperature, half of the samples were subjected to mechanical tests while the other half was left to re-curing with water for 28 days. In this context, the prepared fibrous and non-fibrous mixtures were tested to determine the ultrasonic pulse velocity (UPV), compressive strength, flexural strength, flexural behavior, load carrying and toughness values after ambient temperature, high temperature and water re-curing. Results and conclusion: As a result of the study; it was observed that the UPV values of the mixtures using fibers decreased slightly compared to the reference mixture at ambient temperature. An increase in compressive strength was obtained in all series except for the mixture with 0.40% basalt fiber content at room temperature. This situation showed the negative effect of increasing the basalt fiber content on the compressive strength. The use of fibers caused significant improvements especially in terms of flexural strength, load carrying capacity and toughness. As the samples were exposed to high temperatures, significant decreases were observed in their mechanical properties, especially at temperatures of 600 °C and above. It was determined that re-curing with water had a significant effect on the recovery of the performance of thermally damaged concretes with and without fibers after heating. This recovery was observed to be more pronounced especially at temperatures of 600 °C and above. In terms of flexural strength, re-curing after exposure to 600 °C reached 58.32% of the initial strength of the reference sample and 71.86% of the mixture using 0.80% steel fiber. These values were 30.11% and 41.08%, respectively, before re-curing. Re-curing with water after 800 °C brought the recovery rates of all mixtures closer to each other.

Benzer Tezler

  1. Dispers boyama atık suyunun ozonlama ile geri kazanımı ve tekrar kullanımı

    Decolorisation and reuse of disperse dyeing waste water by ozonation

    ÖZNUR İYİZAMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Tekstil ve Tekstil MühendisliğiUludağ Üniversitesi

    Tekstil Teknolojisi Ana Bilim Dalı

    PROF. DR. HÜSEYİN AKSEL EREN

  2. Profesyonel voleybolcularda antrenman sonrası uygulanan soğuk kompresyonun kas oksijen saturasyonuna ve sıçrama performansına etkisi

    The effect of cold compression on muscle oxygen saturation and jump performance after training in professional volleyball players

    KÜBRA AKAY

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Fizyoterapi ve RehabilitasyonKütahya Sağlık Bilimleri Üniversitesi

    Fizyoterapi ve Rehabilitasyon Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ SEVAL TAMER

  3. Akışla şekillendirme uygulanmış AA7075 kalite alüminyum alaşımının mekanik ve korozyon özelliklerine retrogresyon ve yeniden yaşlandırma işleminin etkisi

    The effect of retrogression and reaging heat treatment on the mechanical and corrosion properties of a flow formed AA7075 aluminum alloy

    EDA URAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    PROF. DR. MURAT BAYDOĞAN

  4. Anaerobic membrane bioreactors for cost-effective municipal water reuse

    Evsel atıksuların anaerobik membran biyoreaktörler ile maliyet etkin olarak yeniden kullanımı

    HALE ÖZGÜN

    Doktora

    İngilizce

    İngilizce

    2015

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. CUMALİ KINACI

    PROF. DR. JULES B. VAN LIER

  5. 8-hidroksikinolin içeren polimer içerikli membranların karakterizasyonu ve metal tutunumu

    Characterization and metal capture of polymer inclusion membranes containing 8-hydroxyquinoline

    ÖGET ÖZMUT KARAKAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    KimyaSakarya Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. AYNUR MANZAK

    DR. ÖĞR. ÜYESİ YASEMİN YILDIZ