Kardiyopulmoner resüsitasyon etkinliğinin değerlendirilmesi: Metronom ve otomatik gerçek zamanlı geri bildirim cihazının karşılaştırılması

Evaluation of cardiopulmonary resuscitation effectiveness: Comparison of metronome and automatic real-time feedback device

  1. Tez No: 931181
  2. Yazar: ZEYNEP AFŞAR YAKIN
  3. Danışmanlar: PROF. DR. AYHAN ÖZHASENEKLER
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Acil Tıp, Emergency Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: Ankara Bilkent Şehir Hastanesi
  11. Ana Bilim Dalı: Acil Tıp Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 73

Özet

Amaç: Kardiyopulmoner resüsitasyon (KPR) esnasında görsel ve işitsel cihazlar kullanılarak hem kardiyak arrest olgularının yönetiminde hem de sağlık personelinin eğitiminde kaliteli KPR yapılmasında bu cihazların etkinliklerini karşılaştırmaktır. Materyal ve Metot: Çalışmamız; ulusal, tek merkezli, prospektif, kontrollü, deneysel manken çalışmasıdır. Çalışma merkezi, Ankara Bilkent Şehir Hastanesi Acil Tıp Kliniği olup; çalışmaya Ankara Yıldırım Beyazıt Üniversitesi Tıp Fakültesi son sınıf öğrencileri dahil edildi. Çalışmaya, Ankara Yıldırım Beyazıt Üniversitesi Sağlık Bilimleri Etik Kurulu onayı alındıktan sonra başlandı. 101 katılımcı çalışmaya dahil edildi. Birinci aşamada; katılımcılardan yetişkin uyumlu maket üzerinde görsel geri bildirim cihazını görerek 2 dakika kesintisiz göğüs basısı yapmaları istendi. Ekrandaki ölçüm değerlerine göre hız, bası derinliği ve geri dolum hızını kendilerinin ayarlamaları istendi. Birinci aşamadan 1 hafta sonra yapılan ikinci aşamada; katılımcılardan geri bildirim cihazı görülmeden, dakikadaki hızı 110 atıma ayarlanan metronom eşliğinde 2 dakika kesintisiz göğüs basısı yapmaları istendi. Geri bildirim cihazı ve metronom eşliğinde yapılan müdahalelerin dakikadaki bası sayısı, bası derinliği ve geri dolum hızı değerleri ölçüldü. Ölçümler geri bildirim cihazı ile gerçekleştirildi. Her iki aşama sonrasında katılımcılardan Likert Ölçeğinde aşamaları değerlendirmeleri istendi. Ayrıca iki aşama arasında uygulanabilirlik, etkinlik ve kolaylık açısından değerlendirilmeleri istendi. Bulgular: Geri bildirim cihazı ile ortalama dakikadaki bası sayısı 107 bası/dk ve metronom ile 109 bası/dk olarak bulundu, yapılan ölçümler istatistiksel olarak anlamlı kabul edildi (p:0,008), fakat klinik olarak anlamlı fark bulunmadı. Geri bildirim cihazı ile ortalama bası derinliği 5,4 cm ve metronom ile ortalama 5,2 cm olarak bulundu, yapılan ölçümler istatistiksel olarak anlamlı kabul edildi (p:0,017), fakat klinik olarak anlamlı fark bulunmadı. Geri bildirim cihazı ile ortalama geri dolum hızı 330 mm/sn ve metronom ile ortalama geri dolum hızı 333 mm/sn olarak bulundu, yapılan ölçümler istatistiksel olarak anlamlı bulunmadı (p:0,939). Her ne kadar bası derinliğinde görsel geri bildirim cihazının daha etkin olduğu görülse de metronom eşliğinde yapılan KPR'deki dakikadaki bası sayısı (geri bildirim cihazında 79-138 bası/dk, metronomda 91-118 bası/dk), bası derinliği (geri bildirim cihazında 4,1-7,8 cm, metronomda 4,1-6,5 cm) ve geri dolum hızlarının (geri bildirim cihazında 82-532 mm/sn, metronomda 239-470 mm/sn) daha dar bir aralıkta dağılım gösterdiği bulundu. Metronom eşliğinde yapılan KPR'nin hem etkinlik hem kolaylık hem de uygulanabilirlik açısından daha yüksek oranlarla (geri bildirim cihazı için %63,4 ve metronom için %72,3) tercih edildiğini saptandı. Geri bildirim cihazı eşliğinde yapılan KPR'de bası sayısı ile bası derinliği arasında anlamlı negatif korelasyon bulundu. Yine geri bildirim cihazı ile yapılan KPR'de bası derinliği ile geri dolum hızı arasında anlamlı pozitif korelasyon bulundu. Metronom eşliğinde yapılan KPR'de bası derinliği ile geri dolum hızı arasında anlamlı pozitif korelasyon bulundu. Sonuç: Kardiyopulmoner resüsitasyonun etkin ve kaliteli olması, tıp alanında çokça üzerinde durulan ve buna yönelik araştırmaların sürekli olarak devam ettiği bir konudur. Çalışmamızdaki bulgulardan yola çıkarak hem metronom hem de görsel geri bildirim cihazı eşliğinde yapılan KPR'de hesaplanan değerler, önerilen değer aralıklarındadır. Metronom ile yapılan KPR'deki parametreler daha dar bir aralıkta dağılım gösterdiği için metronomun daha etkin KPR'ye olanak tanıdığı, uygulayıcılar açısından metronom daha etkili ve daha konforlu bulunduğu, görsel geri bildirim cihazına ulaşmanın kolay olmaması ve buna karşılık metronom uygulaması edinmenin kolaylığı sebebiyle KPR esnasında metronom kullanılmasının daha uygun olabileceği sonucuna varılmıştır.

Özet (Çeviri)

Aim: To compare the effectiveness of visual and auditory devices in performing quality CPR during cardiopulmonary resuscitation (CPR), both in the management of cardiac arrest cases and in the training of healthcare personnel. Materials and Methods: Our study is a national, single-center, prospective, controlled, experimental manikin study. The study center is Ankara Bilkent City Hospital Emergency Medicine Clinic; Ankara Yıldırım Beyazıt University Faculty of Medicine senior students were included in the study. The study was started after the approval of Ankara Yıldırım Beyazıt University Health Sciences Ethics Committee. 101 participants were included in the study. In the first stage; participants were asked to perform chest compressions continuously for 2 minutes on an adult-compatible manikin while seeing the visual feedback device. They were asked to adjust the speed, compression depth and refill rate themselves according to the measurement values ​​on the screen. In the second stage, which was carried out 1 week after the first stage; participants were asked to perform chest compressions continuously for 2 minutes without seeing the feedback device, accompanied by a metronome whose speed was set to 110 beats per minute. The compressions per minute, compression depth and refill rate values ​​of the interventions performed with the feedback device and metronome were measured. The measurements were made with the feedback device. After both stages, participants were asked to evaluate the stages on the Likert Scale. They were also asked to choose between the two stages in terms of applicability, effectiveness and convenience. Results: The average compressions per minute with the feedback device were found to be 107 compressions/min and 109 compressions/min with the metronome, the measurements were considered statistically significant (p:0.008), but no clinically significant difference was found. The average compression depth with the feedback device was found to be 5.4 cm and 5.2 cm with the metronome, the measurements were considered statistically significant (p:0.017), but no clinically significant difference was found. The average refill speed with the feedback device was found to be 330 mm/s and the average refill speed with the metronome was found to be 333 mm/s, the measurements were not found statistically significant (p:0.939). Although the visual feedback device was found to be more effective in terms of compression depth, the number of compressions per minute (79-138 compressions/min in the feedback device, 91-118 compressions/min in the metronome), compression depth (4.1-7.8 cm in the feedback device, 4.1-6.5 cm in the metronome) and refill rates (82-532 mm/sec in the feedback device, 239-470 mm/sec in the metronome) in CPR performed with a metronome were found to have a narrower distribution. It was found that CPR performed with a metronome was preferred with higher rates (63.4% for the feedback device and 72.3% for the metronome) in terms of both effectiveness, convenience and applicability. A significant negative correlation was found between the number of compressions and compression depth in CPR performed with a feedback device. Again, a significant positive correlation was found between compression depth and refill rate in CPR performed with a feedback device. A significant positive correlation was found between compression depth and refill rate in metronome-guided CPR. Conclusion: The effectiveness and quality of cardiopulmonary resuscitation is a subject that is frequently emphasized in the medical field and research on this subject is constantly ongoing. Based on the findings in our study, the values ​​calculated in CPR performed with both a metronome and a visual feedback device are within the recommended value ranges. It was concluded that the metronome allows for more effective CPR since the parameters in CPR performed with a metronome are distributed in a narrower range, the metronome is found to be more effective and more comfortable for practitioners, and the use of a metronome during CPR may be more appropriate due to the difficulty of accessing a visual feedback device and the ease of obtaining a metronome application.

Benzer Tezler

  1. Kişisel koruyucu ekipman ile kardiyopulmoner resüsitasyonda göğüs kompresyonu etkinliğinin değerlendirilmesi, manken çalışması

    Evaluation of the effectiveness of chest compression in cardiopulmonary resusitation with personal protective equipment, mannequin study

    SELİNAY KAYMAKÇI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Acil TıpSakarya Üniversitesi

    Acil Tıp Ana Bilim Dalı

    DOÇ. DR. ONUR KARAKAYALI

  2. 6. sınıf Tıp fakültesi öğrencilerinin kardiyopulmoner resüsitasyon eğitiminde simülasyon eğitim modelinin etkinliğinin değerlendirilmesi

    Assesment the effecti̇veness of si̇mulati̇on trai̇ni̇ng model i̇n cardi̇ trai̇ni̇ng for 6th grade medi̇cal faculty students cardi̇opulmonary resusi̇tati̇on

    MEHMET UMUT AKBULUT

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    Eğitim ve ÖğretimMarmara Üniversitesi

    Acil Tıp Ana Bilim Dalı

    PROF. DR. ARZU DENİZBAŞI ALTINOK

    UZMAN ERKMAN SANRI

  3. Çocuklar hayat kurtarıyor: 'Akran eğitimi modeli' ile ortaokul öğrencilerine uygulanan temel yaşam desteği programının etkinliğinin değerlendirilmesi

    Children save lives: Evaluation of the effectiveness of basic life support program for secondary school students with 'peer education model'

    SEVAL CIBIR

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    HemşirelikZonguldak Bülent Ecevit Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MÜGE SEVAL

  4. Bir şehir hastanesinde dahili kliniklerde çalışan hemşirelere Pecha Kucha yöntemi ile yapılan temel yaşam desteği eğitiminin etkinliğinin değerlendirilmesi

    Evaluation of the effectiveness of basic life support training with Pecha Kucha method to nurses working in internal medicine clinics in a city hospital

    DİLEK ÖZDEMİR ÜRKMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    HemşirelikDemiroğlu Bilim Üniversitesi

    Hemşirelik Ana Bilim Dalı

    PROF. DR. ZEHRA DURNA

  5. Kardiyak arrest vakalarında spontan dolaşımın saptanmasında karotis USG ve karotis doppler USG etkinliğinin değerlendirilmesi

    Evaluation of the effectiveness of carotid USG and carotid doppler USG in detecting spontaneous circulation in cardiac arrest cases

    İBRAHİM DİRGEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Acil TıpSağlık Bilimleri Üniversitesi

    Acil Tıp Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ BURCU BAYRAMOĞLU