Bruksizmli bireylerde iki farklı oklüzal splint materyalinin aşınma miktarı ve hasta memnuniyetinin değerlendirilmesi
Evaluation of wear and patient satisfaction between two different occlusal splint materials in individuals with bruxism
- Tez No: 938205
- Danışmanlar: DOÇ. DR. ERKUT KAHRAMANOĞLU
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Bruksizm, stabilizasyon splinti, dijital üretim, konvansiyonel üretim, aşınma, ağrı, Bruxism, stabilization splint, digital manufacturing, conventional manufacturing, wear, pain
- Yıl: 2025
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı, konvansiyonel ve dijital yöntem ile üretilen stabilizasyon splintlerinin iki gruba ayrılarak, bruksizmli bireylerin altı aylık kullanımı sonucunda splintlerdeki aşınma miktarlarını, hasta memnuniyetini ve aylara göre ağrı değişimini değerlendirmektir. Gereç ve Yöntem: Bruksizm tanısı konulan 30 gönüllü çalışmanın dahil edilme kriterlerine uygun olarak seçildi ve rastgele iki gruba ayrıldı. Ağrı skorları vizüel analog skala kullanılarak subjektif olarak raporlandı ve hasta memnuniyet skorları memnuniyet anketi ile değerlendirildi. Oklüzal splint yüzeyinin hacimsel aşınma miktarı Geomagic yazılımı kullanılarak ölçüldü ve veriler SPSS versiyon 25.0 ile analiz edildi. Bulgular: Altı aylık takip sonucunda konvansiyonel yöntem ile üretilen splintlerin hacimsel kaybı (103,53±41,23) dijital yönteme göre anlamlı olarak daha yüksek bulundu. (62,33 ± 26,29) (p = 0,005) Her ay yapılan değerlendirme sonucunda VAS skorları açısından iki splint grubu arasında anlamlı bir fark bulunmadı. Memnuniyet anketi sonuçları değerlendirildiğinde dijital yöntemdeki sonuçlar konvansiyonele göre anlamlı olarak daha yüksek sonuçlandı. (p<0,001) Sonuç: Oklüzal splintlerdeki aşınma oklüzal temasları değiştirebilir ve splintin tedavi edici etkisini bozabilir; bu nedenle, üretim sırasında aşınmaya dayanıklı malzemeler kullanmak önemlidir. Bulgularımız, dijital üretim süreçlerinin uzun vadeli klinik sonuçları ve hasta memnuniyeti üzerindeki olumlu etkisi nedeniyle avantaj sağladığını göstermektedir.
Özet (Çeviri)
Objective: The aim of this study was to evaluate the wear loss of occlusal splints, patient satisfaction, and pain scores in two groups of individuals with bruxism following six months of use of stabilization splints manufactured by conventional and digital methods. Materials and Methods: A total of 30 individuals diagnosed with bruxism were selected following the inclusion criteria and randomly divided into two groups. Pain scores were subjectively reported using a visual analog scale and patient satisfaction scores were evaluated by a satisfaction questionnaire. Volumetric wear loss of the occlusal splint surface was measured using the Geomagic software. Data were analyzed with SPSS version 25.0. Results: The volumetric loss in the conventional method at the six-month follow-up (103,53±41,23) is significantly higher than that of the digital method. (62,33 ± 26,29)(p= 0,005) There was no significant difference between the two splint types regarding VAS scores during the months. According to the results of the satisfaction questionnaire, the results of the digital method are significantly higher than the conventional method (p<0.001). Conclusion: Occlusal splint wear can gradually alter the balance of occlusal contact and potentially reduce its therapeutic effectiveness, highlighting the importance of using wear-resistant materials. Our findings indicate that digital manufacturing processes provide advantages due to their long-term clinical outcomes and positive impact on patient satisfaction.
Benzer Tezler
- Bruksizmli bireylerin tedavisinde okluzal splintin ve okluzal düzenleme yöntemlerinin etkinliğinin klinik ve deneysel olarak değerlendirilmesi
Başlık çevirisi yok
AHMET SARAÇOĞLU
Doktora
Türkçe
1994
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF.DR. BİRGÜL ÖZPINAR
- Çocuklarda süt dişlenmesi döneminde temporomandibuler düzensizliklerin görülme sıklığı, etyolojisi ve teşhis yöntemleri
The prevalence, etiology and diagnosis of temporomandibular disorders in children primary dentition
TİMUÇİN ARI
- Nokturnal bruksizmin M.Pterigoideus Lateralis ile olan ilişkisinin elektromyografik ve klinik semptomlarının splint kullanımı ile değerlendirilmesi
Evaluation of the relationship between nocturnal bruxism and lateral pterygoid muscle activity by using electromyography and evaluation of the effect of splint therapy on clinical symptoms by comparing the symptoms before and after therapy
NEŞE ORAL
Doktora
Türkçe
2002
Diş HekimliğiHacettepe ÜniversitesiPeriodontoloji Ana Bilim Dalı
PROF. DR. HİLMİ KANSU
DOÇ. DR. FİLİZ KEYF
- Ortodontik ankraj elemanı olarak kullanılan SLA yüzeyli implantlara karşı oluşan doku cevabının klinik, radyografik, histomorfometrik ve histolojik olarak incelenmesi
The clinical, radiological, histomorphometric and histologic evaluation of tissue responses against SLA implants used as orthodontic anchors
MUSA ALDIKAÇTI
Doktora
Türkçe
2002
Diş HekimliğiOndokuz Mayıs ÜniversitesiPeriodontoloji Ana Bilim Dalı
DOÇ.DR. GÖKHAN AÇIKGÖZ
- Okluzal disfonksiyon problemlerinde davranışsal tedavi
Behavioral therapy in occlusal dysfunction problems
ÖZER GİRAY
Yüksek Lisans
Türkçe
2004
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF.DR. TAYFUN BİLGİN