Yeni nesil led ışık cihazlarının farklı yoğunluk modu ve ışınlama süreleri ile çeşitli ortodontik adeziv sistemlerin metal braketlerin bağlanma dayanımına etkisi
The effect of different intensity modes and curing times of new generation led light-curing units and various orthodontic adhesive systems on the shear bond strength of metal brackets
- Tez No: 941089
- Danışmanlar: PROF. DR. ZELİHA MÜGE BAKA
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Bağlanma dayanımı, Işık cihazı, Ortodontik adeziv, Bond strength, Light device, Orthodontic adhesive
- Yıl: 2025
- Dil: Türkçe
- Üniversite: Selçuk Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmanın amacı, ortodontik tedavi amacıyla çekilmiş premolar dişlere metal braketlerin yapıştırılması sırasında kullanılan çeşitli ortodontik adezivlerin ve LED ışık cihazlarının farklı yoğunluk modu ve sürelerinin braketin bağlanma dayanımı üzerine etkisinin in vitro olarak incelenmesidir. Çalışmaya dahil edilen 160 sağlam üst premolar diş rastgele 10 gruba dağıtılmıştır. Grup I'de Transbond XT, Grup II'de BracePaste kullanılarak braketler yapıştırılmıştır. Her iki grup da kullanılan ışık cihazları ve ışınlama modlarına göre 5'er alt gruba ayrılmıştır. Grup Ia ve IIa; Valo standart güç modu ile 10 saniye, Grup Ib ve IIb; Valo yüksek güç modu ile 8 saniye, Grup Ic ve IIc; Valo ekstra güç modu ile 6 saniye, Grup Id ve IId; Woodpecker normal modu ile 10 saniye, Grup Ie ve IIe; Woodpecker turbo modu ile 6 saniye süreyle ışınlanmıştır. Braketler yapıştırıldıktan sonra universal test cihazında örneklerin makaslama bağlanma dayanımı test edilmiştir. Kopma sonrası braket ve diş yüzeyleri stereo mikroskopta incelenmiş ve artık adeziv indeksine göre puanlanmıştır. Bağlanma dayanımı verilerinin istatistiksel analizi için ikili karşılaştırmalarda Mann-Whitney U testi ve çoklu karşılaştırmalarda Kruskal Wallis H testi uygulanmıştır. ARI skoru verilerinin analizinde Ki-kare testi kullanılmıştır. Valo LED ışık cihazının tüm modlarında Transbond XT ile BracePaste'nin bağlanma dayanımı benzer bulunmuştur (p>0,05). Hem Woodpecker LED ışık cihazının tüm modlarında hem de kullanılan ışık cihazlarından bağımsız olarak, Transbond XT'nin bağlanma dayanımı BracePaste'ye göre anlamlı derecede yüksek bulunmuştur (p<0,05). Grup I'de kullanılan ışınlama modları arasında anlamlı bir fark yoktur (p>0,05). Grup II'de ise Valo yüksek güç modu ile Woodpecker normal modu arasında ve Valo ekstra güç modu ile Woodpecker normal ve turbo modları arasında anlamlı fark bulunmuştur (p<0,05). Kullanılan yapıştırıcıdan bağımsız olarak, Valo ekstra güç modu ile Woodpecker normal modu arasında da anlamlı fark vardır (p<0,05). Tüm gruplarda elde edilen bağlanma dayanımı değerleri klinik olarak kabul edilebilir düzeydedir. En yüksek bağlanma dayanımı Transbond XT yapıştırıcı ve Valo'nun ekstra güç modunda 6 saniye polimerizasyonu ile bulunmuştur. En düşük bağlanma dayanımı ise BracePaste yapıştırıcı ve Woodpecker'ın normal modunda 10 saniye polimerizasyonu ile elde edilmiştir. Bağlanma dayanımını hem ortodontik adezivin tipi hem de LED ışık cihazının türü ve farklı ışınlama modları etkilemektedir.
Özet (Çeviri)
The aim of this study was to investigate in vitro the effects of various orthodontic adhesives and different intensity modes and durations of LED light devices used during the bonding of metal brackets to extracted premolar teeth for orthodontic treatment on the bond strength of the bracket. The 160 sturdy upper premolar teeth included in the study were randomly distributed into 10 groups. Brackets were bonded using Transbond XT in Group I and BracePaste in Group II. Both groups were divided into 5 subgroups according to the light devices and curing modes used. Groups Ia and IIa were cured with Valo standard power mode for 10 seconds, Groups Ib and IIb were cured with Valo high power mode for 8 seconds, Groups Ic and IIc were cured with Valo extra power mode for 6 seconds, Groups Id and IId were cured with Woodpecker normal mode for 10 seconds, and Groups Ie and IIe were cured with Woodpecker turbo mode for 6 seconds. After the brackets were bonded, the shear bond strength of the samples was tested on the universal testing machine. After breakage, the bracket and tooth surfaces were examined under a stereo microscope and scored according to the adhesive remnant index. For statistical analysis of the bond strength data, the Mann-Whitney U test was applied for pairwise comparisons and the Kruskal Wallis H test was applied for multiple comparisons. Chi-square test was used in the analysis of ARI score data. In all modes of the Valo LED light device, the bond strength of Transbond XT and BracePaste was found to be similar (p>0.05). Both in all modes of the Woodpecker LED light device and regardless of the light devices used, the bond strength of Transbond XT was found to be significantly higher than BracePaste (p<0.05). There was no significant difference between the curing modes used in Group I (p>0.05). In Group II, there was a significant difference between the Valo high power mode and the Woodpecker normal mode and between the Valo extra power mode and the Woodpecker normal and turbo modes (p<0.05). Regardless of the adhesive used, there was also a significant difference between the Valo extra power mode and the Woodpecker normal mode (p<0.05). The bond strength values obtained in all groups were clinically acceptable. The highest bond strength was found with Transbond XT adhesive and Valo in extra power mode with 6 seconds of polymerization. The lowest bond strength was obtained with BracePaste adhesive and Woodpecker in normal mode with 10 seconds of polymerization. Both the type of orthodontic adhesive and the type of LED light device and different curing modes affect the bond strength.
Benzer Tezler
- Akridin esaslı boyaların ortak duyarlaştırıldığı güneş hücrelerinin fotovoltaik özelliklerinin incelenmesi
Investigation of photovoltaic properties of solar cells sensitized by acridine-based dyes
MELİHA GİZEM BEKMEZ
- Işık kaynaklarının farklı kompozit rezinlerin bulk-fill kompozitle tamirinde bağlanma dayanımı üzerine etkisi
Effect of light sources on bond strength of different composite resins repaired with bulk-fill composite
VAHTİ KILIÇ
Diş Hekimliği Uzmanlık
Türkçe
2018
Cumhuriyet ÜniversitesiRestoratif Diş Tedavisi Ana Bilim Dalı
Yükleniyor...
- Farklı ışık cihazları ve farklı uygulama teknikleri ile polimerize edilen bir posterior kompozitin mikrosertlik, polimerizasyon büzülmesi ve polimerizasyon esnasinda açığa çıkan ısı açısından değerlendirilmesi
The evaluation of microhardness, polymerization shrinkage and the heat released during polymerization of a posterior composite polymerized with different techniques and different light devices
CİHAN ÖZ
- Yeni nesil led ışık cihazlarının fotopolimerizasyon etkinliğinin incelenmesi
Evaluation of photopolymerization efficiency of new generation led curing units
MERVE YÜCEL
Diş Hekimliği Uzmanlık
Türkçe
2019
Marmara ÜniversitesiRestoratif Diş Tedavisi Ana Bilim Dalı
Yükleniyor...
- Fabrication and characterization of P3HT-WO3 hybrid thin films and device applications
P3HT-WO3 hibrit ince filmlerin üretimi, karakterizasyonu ve cihaz uygulamaları
FATMA BEYZA YEDİKARDEŞ ER
Doktora
İngilizce
2024
İstanbul Teknik ÜniversitesiNanobilim ve Nanomühendislik Ana Bilim Dalı
Yükleniyor...