Dijital pet cihazının radyasyon deteksiyon performansının araştırılması

Investigation of radiation detection performance of digital pet device

  1. Tez No: 953644
  2. Yazar: MERVE CİNOĞLU KARACA
  3. Danışmanlar: DR. ÖĞR. ÜYESİ MUSTAFA ÇAĞLAR
  4. Tez Türü: Doktora
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: İstanbul Medipol Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

PET teknolojisi son yıllarda hızla gelişmektedir. Yeni nesil dijital PET (dPET) sistemleri, dijital okumalı silikon fotomultiplier (SiPM) teknolojisine dayanmaktadır ve gelişmiş görüntü çözünürlüğü sunar. Bu çalışmanın amacı, klinikte kurulu bir dPET ile analog PET-1 ve analog PET-2 sistemlerinin, aynı görüntüleme koşulları altında NEMA PET fantomu kullanılarak elde edilen görüntülerdeki küçük lezyonları (özellikle santimetre altı) saptama performanslarını karşılaştırmaktır. Görüntüleme için standart NEMA IEC vücut fantomu kullanılmış ve 4 mm, 5 mm, 6 mm, 8 mm, 10 mm (santimetre altı) ile 13 mm, 17 mm, 22 mm, 28 mm, 37 mm (santimetre üstü) boyutlarındaki lezyonlar değerlendirilmiştir. Görüntüleme süreleri 1, 2, 3, 4 ve 5 dakika olarak belirlenmiş; arka plan-lezyon oranları 1/4 ve 1/8 olacak şekilde, enjeksiyon aktiviteleri ise 2,33–5,33 kBq/ml arasında uygulanmıştır. Görüntü kalitesinin nicel değerlendirmesinde, her lezyon için dairesel bir ROI belirlenmiş ve ortalama aktivite konsantrasyonlarına (ACortalama) göre Kurtarma Katsayısı (RCortalama) hesaplanmıştır. Sonuçlara göre, SiPM teknolojili dPET'in RCortalama değeri, analog PET-2'ye kıyasla yaklaşık %15 daha yüksektir. Ancak analog PET-1'in her iki sisteme göre belirgin bir performans eksikliği olduğu gözlemlenmiştir. İlk nesil dPET sistemleri, görüntü kalitesini artırsa da santimetre altı lezyonlarda PVE etkisini tamamen ortadan kaldıramamaktadır.

Özet (Çeviri)

PET technology has rapidly advanced in recent years. The new generation of digital PET (dPET) systems is based on digital readout silicon photomultiplier (SiPM) technology and offers improved image resolution. The aim of this study is to compare the performance of a clinical dPET system with two analog PET systems (analog PET-1 and analog PET-2) in detecting small lesions—particularly sub-centimeter ones—using images obtained under identical imaging conditions with a NEMA PET phantom. The standard NEMA IEC body phantom was used for imaging, and lesions of 4 mm, 5 mm, 6 mm, 8 mm, and 10 mm (sub-centimeter), as well as 13 mm, 17 mm, 22 mm, 28 mm, and 37 mm (above one centimeter) were evaluated. Imaging durations were set at 1, 2, 3, 4, and 5 minutes. The background-to-lesion ratios were adjusted to 1/4 and 1/8, and the injection activities ranged between 2.33–5.33 kBq/ml. For the quantitative assessment of image quality, a circular ROI was drawn for each lesion, and the Recovery Coefficient (RCmean) was calculated based on the average activity concentrations (ACmean). According to the results, the SiPM-based dPET system showed approximately 15% higher RCmean values compared to analog PET-2. However, analog PET-1 exhibited a marked performance deficiency compared to both systems. While first-generation dPET systems offer improved image quality, they still cannot completely eliminate the adverse effects of PVE in sub-centimeter lesions.

Benzer Tezler

  1. An Experimental and analytical investigation of cam follower jump phenomenon

    Başlık çevirisi yok

    ŞÖLEN ŞEN

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Makine MühendisliğiOrta Doğu Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MEHMET ÇALIŞKAN

  2. A-D, D-A çeviricileri ve -40 derece ile 100 derece arasında çalışan bir dijital termometre tasarım ve yapımı

    Başlık çevirisi yok

    N.GÜLER FENER

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Fizik ve Fizik MühendisliğiGazi Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ATİLLA ÖZMEN

  3. Digital alan kalp hastalarının ilaç kullanımına uyumu ve uyumu etkileyen faktörler

    The Drug adaptability of heart patients taking digitalis and factors affecting the adaptability

    MÜYESSER ERDEM

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    HemşirelikCumhuriyet Üniversitesi

    Hemşirelik Ana Bilim Dalı

    YRD. DOÇ. DR. YUSUF SARIOĞLU

  4. Dört zamanlı türbaşarj direk püskürtmeli bir dizel motorunun bilgisayar ile sümülasyonu

    Computer aided simulation of a fourstroke turbocharged direct-anjection diesel engine

    MUSTAFA BALCI

    Doktora

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiGazi Üniversitesi

    PROF. DR. OĞUZ BORAT

  5. Programlanabilir yüksek akım düşük voltaj güç kaynağı

    The Programmable high currentlow voltage power supply

    ALİ OKUR

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Elektrik ve Elektronik MühendisliğiGazi Üniversitesi

    DOÇ. DR. ATİLLA ÖZMEN