Effect of interimplant distances of implants placed by osseodensification and conventional drilling on primary stability and the evaluation of the temperatures produced by these drilling techniques

Osseodensifikasyon ve konvansiyonel drilleme ile yerleştirilen implantların implantlar arası mesafelerinin primer stabilite üzerine etkisi ve bu drilleme tekniklerinin ürettiği sıcaklıkların değerlendirilmesi

  1. Tez No: 960638
  2. Yazar: BENGİSU KÖMÜ
  3. Danışmanlar: DOÇ. DR. FATİH CABBAR
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: İngilizce
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Dental implantlar, diş eksikliklerini gidermek amacıyla çene kemiğine cerrahi olarak yerleştirilerek doğal diş kökünün fonksiyonunu üstlenen biyouyumlu yapılardır. Bir dental implantın başaralı osseointegrasyonu içinse en önemli adım primer stabilitedir. Bu çalışmanın amacı sığır kaburga kemiklerinde iki farklı implant drilleme tekniği olan; osseodensifikasyon ve konvansiyonel frezlerle yapılan irrigasyonsuz drillemelerin kemikte çıkardığı ısının karşılaştırılması ve bu ısının primer stabiliteye ve nekroz olma durumunu incelemektir. Ayrıca bu iki ayrı grup olan osseodensifikasyon ve konvansiyonel teknikle sokete yerleştirilen implantın 9.7 mm uzaklığına yerleştirilen ikinci implantın ilk implantı primer stabilitesini nasıl etkilediği ve bu iki implantın ortasına yerleştirilen yani implantlara 3 mm uzaklığa yerleştirilen üçüncü İmplantın ilk implantı primer stabilite açısından nasıl etkilediğinin değerlendirilmesidir. (3.7x8mm) boyutlarında toplam 60 implant (Venüs; Türkiye), 20 sığır kaburga kemiğine iki farklı gruba bölünerek osseodensifikasyon tekniği (n=30) ve konvansiyonel teknikle (n=30), her bir kemikte 3 soket oluşturulmuştur. Drilleme esnasında irrigasyonsuz 800 rpmle 60 soket oluşturulmuş ve drillerin çıkardığı ısılar kaydedilmiştir. İmplantlar, 40 rpm hızında çalışan bir fizyo-dispenser ile kemik bloklarına yerleştirilmiştir. Rezonans frekans analizi, SmartPeg kullanılarak gerçekleştirilmiştir. Gruplar arasındaki karşılaştırma ısılar için Student t Test ve Anova testleriyle yapılmıştır. Anlamlılık p<0.05 düzeyinde değerlendirilmiştir. Frez çapları karşılaştırıldığındada Densahın düşük çaplı frezinin ısı ortalamasının tüm frezlerden yüksek olduğu, osseodensifikasyon drillerinin (Densah), konvansiyonel drillere göre daha yüksek ısı ortalamasının olduğu görülmüştür. Osseodensifikasyon yöntemiyle yerleştirilen implantların konvansiyonel yöntemle yerleştirilen implantlara göre ISQ değeri anlamlı olarak yüksek bulunmuştur. Konvansiyonel yöntemle de osseodensifikasyon yöntemiyle de yerleştirilen implantlarda interimplant mesafelerinin isq değerine bir etkisi gözlenmememiştir. Sonuçları desteklemek için geniş ölçekli klinik çalışmalara ihtiyaç vardır.

Özet (Çeviri)

Dental implants are biocompatible structures that are surgically placed into the jawbone to replace missing teeth and function as natural tooth roots. The most critical step for the successful osseointegration of a dental implant is achieving primary stability. The aim of this study is to compare the heat generated in bovine rib bones during irrigation-free drilling using two different implant drilling techniques: osseodensification and conventional drills, and to examine their effects on primary stability and the potential for necrosis. Additionally, the study aims to evaluate how the placement of a second implant at a distance of 9.7 mm from the first implant, using both osseodensification and conventional techniques, affects the primary stability of the first implant. Furthermore, the impact of a third implant placed at a distance of 3 mm from the two implants on the primary stability of the first implant will also be assessed. A total of 60 implants (3.7×8 mm) (Venus; Turkey) were placed into 20 bovine rib bones, divided into two groups: osseodensification technique (n=30) and conventional technique (n=30). Three sockets were created in each bone. During drilling, 60 sockets were created at 800 rpm without irrigation, and the heat generated by the drills was recorded. The implants were placed into bone blocks using a physio-dispenser at a speed of 40 rpm. Resonance frequency analysis was performed using a SmartPeg. Student's t-test and ANOVA were used for the comparison of temperatures between groups. A significance level of p<0.05 was considered statistically significant. When drill diameters were compared, it was observed that the low-diameter drill of Densah had a higher mean temperature than all other drills. Additionally, osseodensification drills (Densah) generated higher mean temperatures compared to conventional drills. Implants placed using the osseodensification technique showed significantly higher ISQ values compared to those placed with the conventional technique. It was observed that interimplant distances had no effect on ISQ values in implants placed with either the conventional or osseodensification technique. Larger-scale clinical studies are needed to support these findings.

Benzer Tezler

  1. Alt çene iki implant destekli hareketli protez (overdenture) uygulamalarında, implantlar arası mesafenin, tutuculuğa etkisinin, farklı sürelerde ve farklı tutuculuk özelliklerinde değerlendirilmesi

    Evaluation of retention effects of interimplant distance on two implant supported mandibular removable prostheses (overdenture) by means of different retention properties and time periods

    HACER ERTÜRK AKYEL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SADULLAH ÜÇTAŞLI

  2. Evaluation of the factors affecting the crestal bone level in implants with different designs

    Farklı tasarıma sahip implantlarda krestal kemik seviyesine etki eden faktörlerin değerlendirilmesi

    TÜMER TEKİN

    Doktora

    İngilizce

    İngilizce

    2023

    Diş HekimliğiAltınbaş Üniversitesi

    Periodontoloji Ana Bilim Dalı

    PROF. DR. GÖKSER ÇAKAR

    DOÇ. DR. BAŞAK BIYIKOĞLU

  3. Dijital implant ölçü netliğinin artırılmasına etkili parametrelerin incelenmesi

    Evaluation of the parameters effecting the accuracy of digital implant impressions

    GÖRKEM GÖKSOY

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BİLGE GÖKÇEN RÖHLİG

  4. Tarama gövdesi yüksekliği, implant açısı ve implantlar arası mesafenin dijital ölçü hassasiyetine etkisi

    Evaluation of the effects of implant depth, angle, and inter-implant distance on the accuracy of intraoral scanning

    NESLİHAN DÜZENOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş HekimliğiHacettepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. MEHMET MUHTAROĞULLARI

  5. İmplant yerleşim derinliğinin, posterior diş varlığının ve farklı tarama stratejilerinin dijital ölçü doğruluğu ve hassasiyeti üzerine etkisi

    The impact of implant placement depth, posterior tooth presence and scanning strategies on accuracy and precision of partial edentulism

    BÜŞRA BOZDOĞAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiAydın Adnan Menderes Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ESRA TALAY ÇEVLİK

    DOÇ. DR. MEHMET ESAD GÜVEN