Effect of scatter correction on quantitative cardiac perfusionspect studies: A Monte Carlo study

Saçılma düzeltmesinin kantitatif kardiyak perfüzyon spect çalışmalarına etkisi: Bir Monte Carlo çalışması

  1. Tez No: 964676
  2. Yazar: MOUNIA EL BAB
  3. Danışmanlar: Prof. Dr. ALBERT GÜVENİŞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Biyo-Medikal Mühendislik Enstitüsü
  11. Ana Bilim Dalı: Nükleer Tıp Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 123

Özet

Bu tez, simülasyona dayalı bir yaklaşımla kantitatif miyokard perfüzyon SPECT görüntülemede saçılma düzeltme (SC) tekniklerinin görüntü kalitesi üzerindeki etkisini incelemektedir. SIMIND Monte Carlo programı ve 4D XCAT fantomu kullanılarak, kalp döngüsünün farklı evrelerini temsil eden sekiz dinamik çerçeve için projeksiyon verileri oluşturulmuştur. Çalışmada, yaygın olarak kullanılan iki saçılma düzeltme yöntemi sistematik olarak değerlendirilmiştir: İkili Enerji Penceresi (DEW, k = 0.5) ve Üçlü Enerji Penceresi (TEW); bu yöntemler, farklı fotopeak pencere genişliklerinde (2, 4 ve 6 keV) ve konfigürasyonlarında (örtüşen ve örtüşmeyen) uygulanmıştır. Görüntüler, OSEM algoritması ile CASTOR yazılımı kullanılarak, üç farklı yeniden yapılandırma koşulunda elde edilmiştir: düzeltmesiz (UC), yalnızca saçılma düzeltmeli (SC) ve hem attenüasyon hem saçılma düzeltmeli (ACSC). Attenüasyon haritaları SIMIND tarafından elde edilmiştir. Kantitatif görüntü analizi dört metrik üzerine odaklanmıştır: sinyal-gürültü oranı (SNR), kontrast-gürültü oranı (CNR), defekt kontrastı ve arka planla göreli gürültü (RNB). Verilerin normal dağılmaması nedeniyle istatistiksel analizlerde parametrik olmayan testler (Friedman ve Wilcoxon işaretli sıra testleri) kullanılmıştır. Sonuçlar, ACSC'nin tüm konfigürasyonlar boyunca CNR, SNR ve defekt kontrastında en yüksek değerlere ulaştığını ve SC ile UC'ye kıyasla üstünlüğünü doğruladığını göstermektedir. Özellikle, yalnızca SC uygulandığında görüntü gürültüsünün azaldığı, ancak UC'ye kıyasla defekt kontrastının da düştüğü gözlemlenmiştir; bu durum, attenüasyon düzeltmesi olmadan uygulandığında bir denge kaybı olabileceğini göstermektedir. Fotopeak pencere genişliği ve örtüşme konfigürasyonlarının görüntü kalitesi metrikleri üzerindeki etkisi minimal olup, istatistiksel olarak anlamlı bir iyileşme gözlenmemiştir. Ayrıca, DEW ve TEW yöntemleri arasındaki karşılaştırmalar çoğu görüntü kalitesi metriğinde anlamlı farklar göstermemiştir; bu da her iki yöntemin benzer performans sağladığını göstermektedir.

Özet (Çeviri)

This thesis explores the effect of scatter correction (SC) techniques on image quality in quantitative myocardial perfusion SPECT imaging through a simulation-based approach. Using the SIMIND Monte Carlo program and the 4D XCAT phantom, projection data were generated for eight dynamic frames representing different phases of the cardiac cycle. The study systematically evaluated two common scatter correction methods: Dual Energy Window (DEW, with k = 0.5) and Triple Energy Window (TEW), applied across various photopeak window widths (2, 4, and 6 keV) and configurations (overlapped and non-overlapped). Images were reconstructed using the CASTOR software with the OSEM algorithm, including three reconstruction conditions: uncorrected (UC), scatter corrected (SC), and both attenuation and scatter corrected (ACSC), with attenuation maps derived from SIMIND. Quantitative image analysis focused on four metrics: signalto-noise ratio (SNR), contrast-to-noise ratio (CNR), defect contrast, and relative noise to background (RNB). Non-parametric statistical tests (Friedman and Wilcoxon signedrank tests) were used due to non-normal data distributions. Results demonstrated that ACSC consistently achieved the highest values in CNR, SNR, and defect contrast across all configurations, confirming its superiority over SC and UC. Notably, SC alone reduced image noise but also led to lower defect contrast compared to UC, indicating a potential trade-off when applied without attenuation correction. The influence of photopeak window width and overlap configuration on image quality metrics was minimal, with no statistically significant improvements observed. Furthermore, comparison between DEW and TEW methods revealed no significant differences in most image quality metrics, suggesting both methods yield comparable performance.

Benzer Tezler

  1. Comparative analysis of OSEM parameters for cardiac SPECT imaging across multiple camera brands: A monte carlo study

    Çoklu kamera markaları arasında kardiyak SPECT görüntülemesi için OSEM parametrelerinin karşılaştırmalı analizi: Bir monte carlo çalışması

    GHASSAN E. I. ABOJAYAB

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Mühendislik BilimleriBoğaziçi Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    Prof. Dr. ALBERT GÜVENİŞ

  2. Nükleer görüntülemede spektral analize dayalı compton saçılması düzeltme yöntemleri

    Compton scatter correction methods based on spectral analysis in nuclear imaging

    KAMİL KÖSEOĞLU

    Doktora

    Türkçe

    Türkçe

    2001

    Nükleer MühendislikEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    DOÇ.DR. GÜNSELİ YAPRAK

  3. Improving the quantification accuracy of Tc-99m mibi dual-phase parathyroid SPECT/ct: Amonte carlo simulation study

    Tc-99m mıbı iki aşamalı paratroit SPECT/ct'nin kuantitatif doğruluğunun artırılması: Bir monte carlo simülasyon çalışması

    BAHADIR AYTAÇ

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    Radyoloji ve Nükleer TıpBoğaziçi Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    PROF. DR. ALBERT GÜVENİŞ

  4. İnternal radyonüklid tedavisinde organ doz hesaplama parametrelerinin optimizasyonu

    Optimization of organ dose calculation parameters in internal radionuclide treatment

    BİLAL KOVAN

    Doktora

    Türkçe

    Türkçe

    2021

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. BAYRAM DEMİR

    PROF. DR. CÜNEYT TÜRKMEN