Geri Dön

Nalokson hidroklorür'ün elektrokimyasal yöntemler ile analizi

Analysis of naloxone hydrochloride by electrochemical methods

  1. Tez No: 971879
  2. Yazar: REYYAN BEYZA BAYKAN
  3. Danışmanlar: PROF. DR. İNCİLAY SÜSLÜ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Eczacılık ve Farmakoloji, Pharmacy and Pharmacology
  6. Anahtar Kelimeler: Eczacılık, Elektrokimya, Elektrokimyasal analiz, Elektrokimyasal sensörler, Pharmacy, Electrochemistry, Electrochemical analysis, Electrochemical sensors
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Analitik Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Nalokson hidroklorür, opioid antagonistler grubunda yer alan ve özellikle opioid kaynaklı aşırı doz vakalarında oluşan solunum depresyonu tedavisinde tercih edilen farmakolojik olarak etkili bir bileşiktir. Bu çalışmada, farmasötik preparatlardaki nalokson hidroklorür'ün tayini için basit, hızlı, güvenilir ve tamamen valide edilmiş kare dalga voltametrisi yöntemi geliştirilmiştir. Çalışma elektrodu olarak kullanılan karbon pasta elektrot, 0.1 M NaOH ve eriokrom siyahı T çözeltisinde 20 döngü uygulanarak dönüşümlü voltametri yöntemi ile modifiye edilmiştir. Böylece karbon pasta elektrot yüzeyinin duyarlılığı artırılmış ve nalokson hidroklorür'ün elektrokimyasal davranışları incelenmiştir. Deneysel koşulların optimizasyonu kapsamında destek elektrolit tipi, pH, analit derişimi, elektropolimerizasyon işlemi ve cihaz parametreleri (frekans, adım yüksekliği ve puls genliği) sistematik olarak değerlendirilmiştir. En uygun destek elektrolit olarak pH'sı 7.0 olan Britton-Robinson tamponu seçilmiştir. Nalokson hidroklorür'ün yükseltgenme tepkimesinin tersinirliği ve pik akımının tipi dönüşümlü voltametri ile araştırılmıştır. Geliştirilen yöntemin seçicilik, doğrusallık, duyarlılık, kesinlik, doğruluk, tutarlılık, sağlamlık ve kararlılık gibi validasyon parametrelerinin değerlendirilmesiyle geçerliliği kanıtlanmıştır. Elde edilen pik akımı, nalokson hidroklorür derişimiyle doğru orantılı olup doğrusallık aralığı 1.33-6.62 ppm (r = 0.9992) aralığında bulunmuştur. Önerilen yöntemin teşhis ve alt tayin sınırları sırasıyla 0.68 ve 1.29 ppm olarak tespit edilmiştir. Valide edilen voltametrik yöntem farmasötik preparatlardaki nalokson hidroklorür'ün tayinine başarıyla uygulanmıştır.

Özet (Çeviri)

Naloxone hydrochloride is a pharmacologically active compound belonging to the group of opioid antagonists and is mainly preferred for the treatment of respiratory depression that occurs in cases of opioid overdose. In this study, a simple, rapid, reliable, and fully validated square-wave voltammetric method was developed for the determination of naloxone hydrochloride in pharmaceutical preparations. The carbon paste electrode used as the working electrode, was modified by cyclic voltammetry through 20 potential cycles in 0.1 M NaOH and eriochrome black T solution. Thus, the sensitivity of the carbon paste electrode surface was increased, and the electrochemical behavior of naloxone hydrochloride was investigated. As part of the optimization of the experimental conditions, the type of supporting electrolyte, pH, analyte concentration, electropolymerization process, and instrumental parameters (frequency, step size and pulse amplitude) were systematically evaluated. Britton-Robinson buffer at pH 7.0 was selected as the most suitable supporting electrolyte. The reversibility of the oxidation reaction of naloxone hydrochloride and the type of its peak current, were investigated using cyclic voltammetry. The validity of the developed voltammetric method was demonstrated by evaluating validation parameters such as selectivity, linearity, sensitivity, precision, accuracy, consistency, robustness and stability. The obtained peak current was directly proportional to the concentration of naloxone hydrochloride and linearity range was found to be between 1.33-6.62 ppm (r = 0.9992). The detection and quantification limits of the proposed method were 0.68 and 1.29 ppm, respectively. The validated voltammetric method was successfully applied for the determination of naloxone hydrochloride in pharmaceutical preparations.

Benzer Tezler

  1. Gama-aminobütirik asit agonistlerinin nükleus akümbens kabuk bölgesine uygulanmasının naloksonla indüklenmiş morfin yoksunluğu üzerindeki etkisi

    Administration of GABA agonists into nucleus accumbens shell on naloxone induced morphine withdrawal

    BETİLAY TOPKARA

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Uyuşturucu Alışkanlığı ve AlkolizmMarmara Üniversitesi

    Dahili Tıp Bilimleri Bölümü

    DOÇ. DR. HASAN RACİ YANANLI

  2. Nalokson, postoperatif analjezide kullanılan morfinin immünosüpresif etkilerini inhibe ediyor mu?

    Does naloxone inhibite immunosuppressive effects of morphine that is used during postoperative analgesia

    HÜSEYİN FİDAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2001

    Anestezi ve ReanimasyonDokuz Eylül Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF.DR. ZAHİDE ELAR

    Y.DOÇ.DR. DENİZ ÖZZEYBEK

  3. Buprenorfin/nalokson idame tedavisindeki opioid bağımlısı hastalarda izlem sonuçlarının değerlendirilmesi

    Evaluation of follow-up results in patients with opioid dependence on buprenorphine/naloxone maintenance treatment

    YUNUS TAYLAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Uyuşturucu Alışkanlığı ve AlkolizmTrakya Üniversitesi

    Ruh Sağlığı ve Hastalıkları Ana Bilim Dalı

    DOÇ. DR. MEHMET BÜLENT SÖNMEZ

  4. Parasetamolün oluşturduğu antinosisepsiyon üzerine nalokson ve flumazenilin etkileri

    The effects of naloxone and flumazenile on paracetamoles antinociceptive effect

    MUSTAFA KAÇMAZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2007

    Anestezi ve ReanimasyonErciyes Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. HALİT MADENOĞLU