Bası ülseri takibine yönelik geliştirilen ph sensörü ve bulut tabanlı izleme sistemi

Ph sensor and cloud-based monitoring system developed for pressure ulcer monitoring

  1. Tez No: 973452
  2. Yazar: FATMA NUR SİPAHİ
  3. Danışmanlar: DOÇ. DR. MÜCELLA ÖZBAY KARAKUŞ, DOÇ. DR. UMUT AYDEMİR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Yozgat Bozok Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tez çalışmasında, bası ülserlerinin takibine ve önlenmesine yönelik IoT tabanlı, entegre ve çok işlevli bir akıllı pansuman sistemi geliştirilmiştir. Sistem; sıcaklık, nem, basınç ve pH parametrelerini eşzamanlı olarak izleyebilmekte, elde edilen verileri NodeMCU ESP8266 mikrodenetleyicisi aracılığıyla Thingspeak platformuna kablosuz şekilde aktarabilmektedir. Böylece yara mikroikliminin dinamik yapısı takip edilmekte, sağlık personeli ve bakım verenler uzaktan izleme imkânına kavuşmakta ve olası enfeksiyon riskleri erken safhada değerlendirilebilmektedir. Ayrıca sistem, sıcaklık ve basınç değerlerinin kritik eşiklerin dışına çıkması durumunda GSM modülü üzerinden sorumlu kişilere anlık alarm gönderecek şekilde tasarlanmıştır. Çalışmanın en özgün katkılarından biri, laboratuvar ortamında üretilen pH sensörüdür. Sensör üretimi optik litografi, hidrotermal büyütme ve dönüşümlü voltametri tekniklerinin entegrasyonuyla gerçekleştirilmiştir. Lazerle indüklenen grafen (LIG) tabakası üzerine hidrotermal yöntemle büyütülen ZnO nanotüpler ve elektropolimerizasyon tekniğiyle kaplanan polianilin (PANI) katmanından oluşan“LIG/ZnO-NTs/PANI”kanal yapısı, yara yüzeyindeki pH değişimlerini yüksek hassasiyetle tespit edebilmiştir. Sensör, pH 5–8 aralığında tekrarlanabilir ve yüksek doğrulukta yanıtlar göstermiş, düşük histerezis (<3.5 mV) ve yüksek korelasyon katsayısı (R² > 0.995) ile güvenilirliğini kanıtlamıştır. Düşük pH seviyelerinde elde edilen yüksek akım yanıtı, PANI'nın protonlanabilir yapısının H⁺ iyonlarına doğrudan tepkisiyle ilişkilendirilmiş; ZnO nanotüplerin geniş yüzey alanı ve LIG tabakasının gözenekli yapısı sensörün iletkenlik ve kararlılığını desteklemiştir. Sonuç olarak geliştirilen sistem çok parametreli izleme ve GSM tabanlı erken uyarı mekanizmasıyla bası ülserlerinin önlenmesi ve yönetilmesinde önemli bir potansiyel sunmaktadır.

Özet (Çeviri)

In this thesis, an IoT-based, integrated, and multifunctional smart dressing system was developed for the monitoring and prevention of pressure ulcers. The system can simultaneously monitor temperature, humidity, pressure, and pH parameters, and wirelessly transmit the resulting data to the Thingspeak platform via the NodeMCU ESP8266 microcontroller. This allows for the dynamic structure of the wound microclimate to be monitored, enabling remote monitoring for healthcare personnel and caregivers, and enabling early assessment of potential infection risks. Furthermore, the system is designed to send instant alarms to responsible parties via the GSM module if temperature and pressure values ​​exceed critical thresholds. One of the most novel contributions of this study is the pH sensor produced in a laboratory environment. The sensor fabrication was achieved by integrating optical lithography, hydrothermal growth, and cyclic voltammetry techniques. The“LIG/ZnO-NTs/PANI”channel structure, consisting of ZnO nanotubes grown via hydrothermal methods on a laser-induced graphene (LIG) layer and a polyaniline (PANI) layer coated via electropolymerization, was able to detect pH changes on the wound surface with high sensitivity. The sensor demonstrated repeatable and highly accurate responses in the pH range of 5–8, demonstrating its reliability with low hysteresis (<3.5 mV) and a high correlation coefficient (R² > 0.995). The high current response obtained at low pH levels was attributed to the direct response of the protonable structure of PANI to H⁺ ions. The large surface area of ​​the ZnO nanotubes and the porous structure of the LIG layer supported the conductivity and stability of the sensor. In conclusion, the developed system offers significant potential in the prevention and management of pressure ulcers through multi-parameter monitoring and a GSM-based early warning mechanism.

Benzer Tezler

  1. Farelerde oluşturulan bası ülseri sırasında verilen curcumin ve balık yağının bası ülseri üzerindeki etkinliğinin araştırılması

    İnvestigation of the efficacy of curcumin and fish oil on the pressure ulcer during the formation of prassure ulcer in mice

    SEVİL TULTAK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    Anestezi ve ReanimasyonEskişehir Osmangazi Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. BİRGÜL YELKEN

  2. Sıçanlarda oluşturulan bası ülseri modelinde lokal ve sistemik ozonun yara iyileşmesi üzerine etkileri

    Effects of local and systemic ozone on wound healing in a pressure ulcer model in rats

    HÜSEYİN GÖKÇENOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    Anestezi ve ReanimasyonSağlık Bilimleri Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. ÜLKÜ AYGEN TÜRKMEN

  3. DİYABETİK HASTALARDA PLANTAR ÖN AYAK ÜLSERİ TEDAVİSİNDE AŞİL TENDON UZATMA CERRAHİSİ İLE TOTAL TEMASLI ALÇI GRUPLARININ ÜLSER PROGNOZU, YÜRÜME ANALİZİ VE STATİK BASI ANALİZİNE ETKİLERİNİN KARŞILAŞTIRILMASI

    Comparison of the Effects of Achilles Tendon Lengthening Surgery and Total Contact Casting on Ulcer Prognosis, Gait Analysis, and Static Pressure Analysis in the Treatment of Forefoot Plantar Ulcers in Diabetic Patients

    MEHMET AKKURT

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Plastik ve Rekonstrüktif CerrahiSağlık Bilimleri Üniversitesi

    Plastik Rekonstrüktif ve Estetik Cerrahi Ana Bilim Dalı

    DOÇ. DR. ÇAĞLA ÇİÇEK