Vidalı implant üstü sabit restorasyonlarda protetik komponent tercihinin ve implant açılanmalarının protetik vida üzerindeki mekanik etkisi

The mechanical effect of different implant angles and prosthetic component preference on implant supported screw retained prosthetis's screw

  1. Tez No: 974382
  2. Yazar: KÜBRA NUR DURAN İLHAN
  3. Danışmanlar: DOÇ. DR. GÜLSÜM SAYIN ÖZEL
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: İstanbul Medipol Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı implant konumunun açısal farklılıkları ile abutment seçiminin implant-abutment bileşenlerinin mekanik dayanıklılığı üzerindeki etkilerini değerlendirmek ve abutment vidalarında görülebilecek deformasyonları mikro-BT analiziyle incelemektir. Çalışmamızda; her biri 4.1 mm çapında ve 12 mm uzunluğunda olan 40 adet titanyum implant, akrilik rezin modellerine hem düz hem de açılı pozisyonlarda yerleştirilmiştir. Örnekler; düz yerleştirilmiş implant ve Ti-base abutment kronu (Ti-1), açılı yerleştirilmiş implant ve Ti-base abutment kronu (Ti-2), düz yerleştirilmiş implant ve Multi-unit abutment kronu (MU-1), açılı yerleştirilmiş implant ve Multi-unit abutment kronu (MU-2) olarak 4 gruba ayrılmıştır (n=10). Tüm gruplar, distile su içerisinde 5.000 döngü, 5-50 °C sıcaklık aralığında, 30 saniyelik bekleme süresi ile termal yaşlandırma işlemine tabi tutulmuştur. Her bir örneğe, evrensel test cihazı ile yarı-statik yük uygulanmış ve deformasyon sırasında oluşan maksimum kuvvet değerleri kaydedilmiştir. Deformasyon tipleri mikro-BT ve SEM görüntüleme yöntemleri ile belirlenmiştir. Çalışma gruplarının deformasyon gösterdikleri ortalama kuvvet değerleri sırasıyla Ti-1 grubu için 2589 N, Ti-2 grubu için 1768 N, MU-1 grubu için 3318 N ve MU-2 grubu için 2213 N olarak kaydedilmiştir. MU-1 grubu, Ti-1, Ti-2 ve MU-2 gruplarına kıyasla daha yüksek kuvvet değerinde deformasyon gösterniştir. Tüm gruplarda vida bükülmesi gözlenmiştir. Ti-2, MU-1 ve MU-2 gruplarında abutment vidalarındaki bükülme açılanmasında anlamlı fark saptanırken, Ti-1 grubunda istatistiksel olarak anlamlı bir fark bulunmamıştır (p=0,001; p<0,05). Çalışmamızın sonucunda abutment tercihi ve implant yerleştirme açısı, implant-abutment kompleksinin maksimum yük taşıma kapasitesini etkileyebilmektedir. Hem Ti-base hem de Multi-unit abutmentlar ağız içi kuvvetlerinden daha yüksek kuvvetlere karşı direnç sergilemiştir. Her iki abutment da protetik tedavilerde güvenli olarak kullanılabilir.

Özet (Çeviri)

This study aims to evaluate the effects of angular differences in implant position and abutment selection on the mechanical strength of implant-abutment components and to examine deformations that may occur in abutment screws using micro-CT analysis. Forty titanium implants, each 4.1 mm in diameter and 12 mm in length, were placed in acrylic resin models in both straight and angled positions. The samples were divided into 4 groups: straight-placed implant and Ti-base abutment crown (Ti-1), angled-placed implant and Ti-base abutment crown (Ti-2), straight-placed implant and Multi-unit abutment crown (MU-1), and angled-placed implant and Multi-unit abutment crown (MU-2) (n=10). All groups were subjected to thermal aging in distilled water at a temperature range of 5-50 °C for 5,000 cycles with a 30-second dwell time. Each sample was subjected to a semi-static load using a universal testing machine, and the maximum force values during deformation were recorded. Deformation types were determined using micro-CT and SEM imaging methods. The average force values at which the groups showed deformation were recorded as 2589 N for the Ti-1 group, 1768 N for the Ti-2 group, 3318 N for the MU-1 group, and 2213 N for the MU-2 group. The MU-1 group exhibited deformation at a higher force value compared to the Ti-1, Ti-2, and MU-2 groups. Screw bending was observed in all groups. A significant difference was found in the bending angle of the abutment screws in the Ti-2, MU-1, and MU-2 groups, while no statistically significant difference was found in the Ti-1 group (p=0.001; p<0.05). This study showed that abutment choice and implant placement angle can affect the maximum load-bearing capacity of the implant-abutment complex. Both Ti-base and Multi-unit abutments have demonstrated resistance to forces higher than intraoral forces. Both abutments can be used safely in prosthetic treatments.

Benzer Tezler

  1. İmplant destekli vida tutuculu restorasyonlarda restoratif vida ve materyallerin mekanik davranışlarının incelenmesi

    Mechanical behavior of restorative screws and materials in implant supported screw-retained restorations

    ADİL İSMAİL SOYKASAP

    Doktora

    Türkçe

    Türkçe

    2025

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. BÜLENT GÖKÇE

  2. Antirotasyonel mekanizması olan ve olmayan vidalı abutmentların vida gevşemesi ve abutment aşınması açısından in-vitro olarak karşılaştırılması

    An in vitro comparison of screw loosening and abutment wearin screw-retained abutments with and without antirotational mechanism

    EYLÜL BERKER ZENGİNER

    Doktora

    Türkçe

    Türkçe

    2026

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ONUR GEÇKİLİ

  3. In-Vitro examination of screw loosening and abutment wear in screw retained i̇mplant supported bridge prostheses

    İmplant üstü okluzal vidalı köprü protezlerinde vida gevşemesi ve abutment aşınmasının In-Vitro incelenmesi

    ELİF GÖZDE NALBANTOĞLU

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ONUR GEÇKİLİ

  4. Atrofik posterior maksillanın rehabilitasyonunda farklı implant planlamalarının ve farklı protez tasarımlarının stres dağılımına etkilerinin sonlu elemanlar analizi ile incelenmesi

    Investigation of the effects of different implant planning and different prosthesis designs on stress distribution in rehabilitation of atrophic posterior maxilla by finite element analysis

    ARZU YÜKSEL BAYSAL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiTokat Gaziosmanpaşa Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. YELİZ HAYRAN

  5. İmplant destekli tam ark sabit protezlerde farklı üretim yöntemleri kullanılarak üretilen farklı alt yapı materyallerinin uyumlarının karşılaştırılması

    Comparison of the fit of various framework materials manufactured through different production methods in implant supported complete-arch fixed prostheses

    EYLÜL TÜRSEN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BÜLENT GÖKÇE