Geri Dön

Spinal anestezi uygulanan elektif sezaryen olgularında kullanılan varis çorabı ve bacak elevasyonunun maternal intraoperatif hipotansiyon ve yenidoğan parametreleri üzerine etkisi

The effect of compression stockings and leg elevation on maternal intraoperative hypotension and neonatal parameters in elective cesarean sections performed under spinal anesthesia

  1. Tez No: 1003307
  2. Yazar: SEÇİL YAVAŞ
  3. Danışmanlar: DOÇ. DR. TÜLAY BÜLBÜL
  4. Tez Türü: Doktora
  5. Konular: Kadın Hastalıkları ve Doğum, Obstetrics and Gynecology
  6. Anahtar Kelimeler: Bacak Elevasyonu, Hipotansiyon, Randomize Kontrollü Çalışma, Spinal Anestezi, Sezaryen, Varis Çorabı, Cesarean Delivery, Compression Stockings, Hypotension, Leg Elevation, Randomized Controlled Trial, Spinal Anesthesia
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Erciyes Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Hemşirelik Ana Bilim Dalı
  12. Bilim Dalı: Doğum, Kadın Sağlığı ve Hastalıkları Hemşireliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu araştırmanın amacı, spinal anestezi uygulanan elektif sezaryen olgularında varis çorabı kullanımı ve bacak elevasyonunun maternal intraoperatif hipotansiyon, vazopressör gereksinimi ve yenidoğan iyilik hali parametreleri üzerine etkisini değerlendirmektir. Bu çalışma tek kör, randomize kontrollü deneysel bir araştırma olarak planlanmış ve Afşin Devlet Hastanesi kadın doğum servisi ve ameliyathanesinde 1 Kasım 2023-20 Şubat 2025 tarihleri arasında yürütülmüştür. Araştırmaya dahil edilme kriterlerini karşılayan toplam 90 gebe randomizasyon yöntemiyle üç gruba ayrılmıştır: varis çorabı grubu (n=30), bacak elevasyonu grubu (n=30) ve kontrol grubu (n=30). Tüm olgularda spinal anestezi standart protokole uygun şekilde uygulanmıştır. Varis çorabı grubuna ameliyat öncesi varis çorabı giydirilmiş, bacak elevasyonu grubuna spinal anestezi sonrası bacak elevasyonu uygulanmış ve kontrol grubuna ise rutin cerrahi prosedür uygulanmıştır. Maternal sistolik, diyastolik ve ortalama arter basıncı ile kalp atım hızı intraoperatif dönemde düzenli aralıklarla izlenmiş; hipotansiyon gelişimi, vazopressör kullanımı, bulantı ve kusma gibi yan etkiler kaydedilmiştir. Yenidoğanlara ait 5. Dakika APGAR skoru ile umblikal ven kan gazı pH ve baz eksisi değerleri değerlendirilmiştir. Verilerin analizi uygun istatistiksel yöntemler kullanılarak gerçekleştirilmiştir. Varis çorabı ve bacak elevasyonu uygulanan gruplarda intraoperatif sistolik, diyastolik ve ortalama arter basıncı değerlerinin kontrol grubuna kıyasla anlamlı düzeyde daha yüksek olduğu saptanmıştır (P < 0,05). Her iki müdahale grubunda vazopressör kullanım oranı kontrol grubuna göre anlamlı derecede düşük bulunmuştur (Varis çorabı %46,7, bacak elevasyonu %60, kontrol %86,7) (P < 0,05). Yenidoğan APGAR skoru, umblikal ven pH ve baz eksisi değerleri açısından gruplar arasında istatistikler olarak anlamlı bir fark bulunmamıştır (P >0,05). Spinal anestezi altında elektif sezaryen uygulanan gebelerde varis çorabı kullanımı ve bacak elevasyonunun, maternal hemodinamik stabilitenin korunmasında etkili, güvenli ve uygulanabilir non-farmakolojik yöntemler olduğu tespit edilmiştir.

Özet (Çeviri)

This study aimed to evaluate the effects of compression stockings and leg elevation on maternal intraoperative hypotension, vasopressor requirement, and neonatal well-being parameters in elective cesarean deliveries performed under spinal anesthesia. This single-blind, randomized controlled experimental study was conducted in the obstetrics and operating rooms of Afşin State Hospital between November 1, 2023, and February 20, 2025. A total of 90 pregnant women who met the inclusion criteria were randomly assigned to three groups: compression stockings group (n=30), leg elevation group (n=30), and control group (n=30). Spinal anesthesia was administered according to a standardized protocol in all cases. Compression stockings were applied preoperatively in the compression stocking group, leg elevation was performed after spinal anesthesia in the leg elevation group, and routine surgical procedures were applied in the control group. Maternal systolic, diastolic, and mean arterial pressures and heart rate were monitored at regular intervals intraoperatively; the occurrence of hypotension, vasopressor use, and adverse effects such as nausea and vomiting were recorded. Neonatal outcomes included 5-minute APGAR scores and umbilical venous blood gas pH and base excess. Data were analyzed using appropriate statistical methods. Intraoperative systolic, diastolic, and mean arterial pressure values were significantly higher in both the compression stockings and leg elevation groups compared with the control group (P < 0,05). The proportion of vasopressor use was significantly lower in both intervention groups than in the control group (Compression stockings 46.7%, leg elevation 60%, control 86.7%) (P < 0,05). No statistically significant differences were found among the groups in neonatal APGAR scores, umbilical venous pH, or base excess (P >0,05). The use of compression stockings and leg elevation was found to be effective, safe, and feasible non-pharmacological interventions for maintaining maternal hemodynamic stability in pregnant women undergoing elective cesarean delivery under spinal anesthesia.

Benzer Tezler

  1. Spinal anestezi ile gerçekleştirilen sezaryen olgularında: postoperatif ultrason eşliğinde levobupivakain veya bupivakain ile yapılan tap (transversus abdominis plane) bloğunda lokal anesteziklerin etkinliklerinin retrospektif olarak karşılaştırılması.

    In caesarean delivery under spinal anesthesia: retrospective comparison the effects of local anaesthetics on postoperative ultrason guided tap block with levobupivacaine or bupivacaine

    MURAT ASILİSKENDER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    Anestezi ve ReanimasyonGata

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. HÜSEYİN ŞEN

    PROF. DR. SEZAİ ÖZKAN

  2. Sezaryen operasyonlarında spinal anestezide kullanılan iki farklı düşük doz bupivakainin anestezi kalitesi ve intraoperatif hemodinamiye olan etkilerinin karşılaştırılması

    Comparison of the effects of the two different low doses of bupivacaine used in spinal anesthesia during cesarean operations, on the quality of the anesthesia and the i̇ntraoperative hemodynamics

    ÖMER DOYMUŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2019

    Anestezi ve ReanimasyonAtatürk Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. AYŞENUR DOSTBİL

  3. Gebelerde spinal anestezi sırasında oluşan sempatik blokajın düşük doz yavaş uygulanan intravenöz atropin ile preemptif sağaltımı

    Preemptive treatment of sympathetic blockade during spinal anesthesia in pregnant women with slow administration of low dose atropine

    AHMET TUBAY

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Anestezi ve ReanimasyonBolu Abant İzzet Baysal Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. AKCAN AKKAYA

  4. Sezaryen anestezisi için intratekal uygulanan farklı dozlarda levobupivakain ve fentanil kombinasyonun etkileri

    The effect of different doses of levobupivacaine and fentanyl combination on spinal anesthesia at secarean section

    BEDİH BALKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2007

    Anestezi ve ReanimasyonDicle Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ.DR. GÖNÜL ÖLMEZ

    Y.DOÇ.DR. HAKTAN KARAMAN

    Y.DOÇ.DR. SEDAT KAYA

  5. Spinal anestezi ile yapılan sezaryen operasyonlarında intratekal artikaine morfin eklenmesinin anestezi ve postoperatif analjezi üzerine etkisi

    The effects of morphine in addition to spinal articaine in caesarean section

    ADNAN YALDIZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2012

    Anestezi ve ReanimasyonFatih Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. MUHAMMET GÖZDEMİR