Geri Dön

Üç boyutlu yazıcı kullanılarak hazırlanan süt azı kuronlarında farklı siman aralıklarının kırılma direnci üzerindeki etkisinin ı̇n vitro karşılaştırılması

In vitro comparative evaluation of the effect of different cement space parameters on the fracture resistance of three-dimensionally printed primary molar crowns

  1. Tez No: 1012877
  2. Yazar: MUHAMMET BURAK YAZICI
  3. Danışmanlar: DOÇ. DR. FATİH ŞENGÜL
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: 3 boyutlu yazıcı, kırılma dayanımı, siman, siman aralığı, Three-dimensional printing, fracture resistance, cement, cement space
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Pedodonti Ana Bilim Dalı
  12. Bilim Dalı: Pedodonti Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu tez çalışmasında, üç boyutlu yazıcı kullanılarak üç farklı siman aralığında üretilen süt azı kuronlarının üç farklı siman kullanılarak simante edilmesi sonrasında kırılma dayanımlarının incelenmesi amaçlanmıştır. Materyal ve Metot: Çalışma, Atatürk Üniversitesi Diş Hekimliği Fakültesi Ar-Ge Laboratuvarı'nda gerçekleştirilmiştir. Üç boyutlu yazıcı kullanılarak üç farklı siman aralığında (25 μm, 50 μm ve 100 μm) toplam 225 adet süt azı kuronu üretilmiş ve üç farklı siman kullanılarak (rezin modifiye cam iyonomer siman, cam iyonomer siman ve rezin siman) metal güdüklere simante edilmiştir. Örneklere üniversal test cihazı ile kırılma dayanımı testi uygulanmıştır. Elde edilen veriler istatistiksel olarak değerlendirilmiştir. Bulgular: Rezin siman kullanılarak simante edilen kuronların en düşük kırılma oranını (%45.3) ve en yüksek tahmini medyan kırılma değerini (2048.5 N) sergilediği belirlenmiştir. Kuronların kırılma oranları ve tahmini medyan kırılma değerleri incelendiğinde rezin simanı sırasıyla cam iyonomer siman (%73.3, 1782.5 N) ve rezin modifiye can iyonomer (%93.3, 1626.7 N) siman takip etmiştir (p <0.001). Siman aralığı değişkeninin kırılma dayanımı üzerinde istatistiksel olarak anlamlı bir etkisi olmadığı tespit edilmiştir (p>0.05) Sonuç: Üç boyutlu yazıcı kullanılarak üretilen süt azı kuronlarının kırılma dayanımları siman aralığı değişkeninden etkilenmezken, kullanılan siman türünden etkilenmiştir. Simanların kırılma dayanımları büyükten küçüğe doğru rezin siman, cam iyonomer siman ve rezin modifiye cam iyonomer siman şeklinde olup tüm grupların kırılma değerleri çocuklarda oluşabilecek ağız içi kuvvetlerin üzerinde bulunmuştur. Sonuçların klinik ortama genellenebilmesi için uzun dönemli ve in vivo çalışmalarla desteklenmesi gerekmektedir.

Özet (Çeviri)

Aim: The aim of this thesis was to evaluate the fracture resistance of three-dimensionally printed primary molar crowns fabricated with three different cement space parameters following cementation with three different luting agents. Materials and Methods: The study was conducted at the Research and Development Laboratory of the Faculty of Dentistry, Atatürk University. A total of 225 primary molar crowns were fabricated using a three-dimensional printer with three different cement space parameters (25 μm, 50 μm, and 100 μm) and were cemented onto metal dies using three different luting agents (resin-modified glass ionomer cement, glass ionomer cement, and resin cement). Fracture resistance testing was performed using a universal testing machine. The obtained data were statistically analyzed. Results: Crowns cemented with resin cement exhibited the lowest fracture rate (45.3%) and the highest estimated median fracture load (2048.5 N). Evaluation of fracture rates and estimated median fracture loads demonstrated that resin cement was followed by glass ionomer cement (73.3%, 1782.5 N) and resin-modified glass ionomer cement (93.3%, 1626.7 N), respectively (p <0.001). The cement space parameter was found to have no statistically significant effect on fracture resistance (p> 0.05). Conclusion: The fracture resistance of three-dimensionally printed primary molar crowns was not influenced by the cement space parameter, whereas it was significantly affected by the type of luting agent used. The fracture resistance values of the cements, in descending order, were resin cement, glass ionomer cement, and resin-modified glass ionomer cement. The fracture loads of all groups exceeded the intraoral forces typically encountered in pediatric patients. Further long-term and in vivo studies are required to support the generalization of these findings to clinical conditions.

Benzer Tezler

  1. Farklı 3 boyutlu yazıcı sistemleri ile hazırlanan kompozit örneklerin süt dişi sert dokularıyla olan bağlanma dayanımlarının mikro makaslama test metodu ile değerlendirilmesi ve kopma modellerinin stereomikroskop ile incelenmesi

    Assessment of the micro shear bond strenght of additively manufactured composite resins produced by different 3D printer systems to hard tissues of primary tooth and stereomicroscope analyses of bonded interfaces

    ERVA GÜNGÖR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiSağlık Bilimleri Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MERVE AKSOY

  2. Kahve ısıl döngüsünün eklemeli ve eksiltmeli yöntemler ile üretilen daimi kron materyallerinin mikrosertliği, yüzey pürüzlülüğü, yüzey özellikleri ve renk stabilitesi üzerindeki etkisi

    The effect of coffee thermal cycling on the microhardness, surface roughness, surface properties, and color stability of permanent crown materials manufactured via additive and subtractive techniques

    NURGÜL ERSOY

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş HekimliğiFırat Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. SAMET TEKİN

  3. Süt dişlerinde farklı 3d baskı sistemi ile üretilen restorasyonların kırılma dayanımlarının değerlendirilmesi

    Fractured load of 3d printed restorations in different thickness for primary molars

    NİLGE SARIMEHMETOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiOrdu Üniversitesi

    Pedodonti Ana Bilim Dalı

    DOÇ. DR. HÜSEYİN ŞİMŞEK

  4. Farklı üç boyutlu yazıcılar kullanılarak hazırlanan biyobazlı mandibular implant modellerinin boyutsal stabilitesi ve pozisyonel doğruluğu

    Dimensional stability and positional accuracy of biobased mandibular implant models fabricated using different three-dimensional printers

    BETÜL MARANGOZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2026

    Diş HekimliğiOrdu Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. DOĞU ÖMÜR DEDE

    DOÇ. DR. AHMET SERKAN KÜÇÜKEKENCİ